3,125 research outputs found
emission rates in absorptions at rest on Li, Li, Be, C and O
An experimental study of the reaction
on Li, Li, Be, C and O -shell nuclei is
presented. The data were collected by the FINUDA spectrometer operating at the
DANE -factory (LNF-INFN, Italy). Emission rates for the reaction in
the mentioned nuclei are measured and compared with the few existing data. The
spectra of several observables are discussed; indications of Quasi-Free
absorptions by a pair embedded in the nucleus can be obtained from
the study of the missing mass distributions.Comment: Version accepted by PR
New detectors for the kaon and hypernuclear experiments with KaoS at MAMI and with PANDA at GSI
The KaoS spectrometer at the Mainz Microtron MAMI, Germany, is perceived as
the ideal candidate for a dedicated spectrometer in kaon and hypernuclei
electroproduction. KaoS will be equipped with new read-out electronics, a
completely new focal plane detector package consisting of scintillating fibres,
and a new trigger system. First prototypes of the fibre detectors and the
associated new front-end electronics are shown in this contribution. The Mainz
hypernuclei research program will complement the hypernuclear experiments at
the planned FAIR facility at GSI, Germany. At the proposed antiproton storage
ring the spectroscopy of double Lambda hypernuclei is one of the four main
topics which will be addressed by the PANDA Collaboration. The experiments
require the operation of high purity germanium (HPGe) detectors in high
magnetic fields (B= 1T) in the presence of a large hadronic background. The
performance of high resolution Ge detectors in such an environment has been
investigated.Comment: Presentation at International Symposium on the Development of
Detectors for Particle, Astroparticle and Synchrotron Radiation Experiments,
Stanford, Ca (SNIC06), 6 pages, LaTeX, 11 eps figure
Performance of HPGe Detectors in High Magnetic Fields
A new generation of high-resolution hypernuclear gamma$-spectroscopy
experiments with high-purity germanium detectors (HPGe) are presently designed
at the FINUDA spectrometer at DAPhiNE, the Frascati phi-factory, and at PANDA,
the antiproton proton hadron spectrometer at the future FAIR facility. Both,
the FINUDA and PANDA spectrometers are built around the target region covering
a large solid angle. To maximise the detection efficiency the HPGe detectors
have to be located near the target, and therefore they have to be operated in
strong magnetic fields B ~ 1 T. The performance of HPGe detectors in such an
environment has not been well investigated so far. In the present work VEGA and
EUROBALL Cluster HPGe detectors were tested in the field provided by the ALADiN
magnet at GSI. No significant degradation of the energy resolution was found,
and a change in the rise time distribution of the pulses from preamplifiers was
observed. A correlation between rise time and pulse height was observed and is
used to correct the measured energy, recovering the energy resolution almost
completely. Moreover, no problems in the electronics due to the magnetic field
were observed.Comment: submitted to Nucl. Instrum. Meth. Phys. Res. A, LaTeX, 19 pages, 9
figure
A study of the proton spectra following the capture of in Li and C with FINUDA
Momenta spectra of protons emitted following the capture of in Li
and C have been measured with 1% resolution. The C spectrum is
smooth whereas for Li a well defined peak appears at about 500 MeV/. The
first observation of a structure in this region was identified as a strange
tribaryon or, possibly, a -nuclear state. The peak is correlated with a
coming from decay in flight, selected by setting momenta
larger than 275 MeV/. The could be produced, together with a 500
MeV/ proton, by the capture of a in a deuteron-cluster substructure of
the Li nucleus. The capture rate for such a reaction is (1.62\pm
0.23_{stat} ^{+0.71}_{-0.44}(sys))%/K^-_{stop}, in agreement with the existing
observations on He targets and with the hypothesis that the Li nucleus
can be interpreted as a cluster.Comment: 21 pages, 10 figures. Accepted for publication in NP
Status of cosmic-ray antideuteron searches
The precise measurement of cosmic-ray antiparticles serves as important means
for identifying the nature of dark matter. Recent years showed that identifying
the nature of dark matter with cosmic-ray positrons and higher energy
antiprotons is difficult, and has lead to a significantly increased interest in
cosmic-ray antideuteron searches. Antideuterons may also be generated in dark
matter annihilations or decays, offering a potential breakthrough in unexplored
phase space for dark matter. Low-energy antideuterons are an important approach
because the flux from dark matter interactions exceeds the background flux by
more than two orders of magnitude in the low-energy range for a wide variety of
models. This review is based on the "dbar14 - dedicated cosmic-ray antideuteron
workshop", which brought together theorists and experimentalists in the field
to discuss the current status, perspectives, and challenges for cosmic-ray
antideuteron searches and discusses the motivation for antideuteron searches,
the theoretical and experimental uncertainties of antideuteron production and
propagation in our Galaxy, as well as give an experimental cosmic-ray
antideuteron search status update. This report is a condensed summary of the
article "Review of the theoretical and experimental status of dark matter
identification with cosmic-ray antideuteron" (arXiv:1505.07785).Comment: 9 pages, 4 figures, ICRC 2015 proceeding
Correlated pairs from the reaction
Correlated pairs emitted after the absorption of negative kaons
at rest in light nuclei and are
studied. -hyperons and deuterons are found to be preferentially
emitted in opposite directions. The invariant mass spectrum of
shows a bump whose mass is 32516 MeV/c. The bump mass (binding
energy), width and yield are reported. The appearance of a bump is discussed in
the realm of the [] clustering process in nuclei. The experiment was
performed with the FINUDA spectrometer at DANE (LNF).Comment: 13 pages, 5 figures, accepted for publication in Phys. Lett.
INFN What Next: Ultra-relativistic Heavy-Ion Collisions
This document was prepared by the community that is active in Italy, within
INFN (Istituto Nazionale di Fisica Nucleare), in the field of
ultra-relativistic heavy-ion collisions. The experimental study of the phase
diagram of strongly-interacting matter and of the Quark-Gluon Plasma (QGP)
deconfined state will proceed, in the next 10-15 years, along two directions:
the high-energy regime at RHIC and at the LHC, and the low-energy regime at
FAIR, NICA, SPS and RHIC. The Italian community is strongly involved in the
present and future programme of the ALICE experiment, the upgrade of which will
open, in the 2020s, a new phase of high-precision characterisation of the QGP
properties at the LHC. As a complement of this main activity, there is a
growing interest in a possible future experiment at the SPS, which would target
the search for the onset of deconfinement using dimuon measurements. On a
longer timescale, the community looks with interest at the ongoing studies and
discussions on a possible fixed-target programme using the LHC ion beams and on
the Future Circular Collider.Comment: 99 pages, 56 figure
Search for the pentaquark via the reaction at 1.92 GeV/
The pentaquark baryon was searched for via the
reaction in a missing-mass resolution of 1.4 MeV/(FWHM) at J-PARC.
meson beams were incident on the liquid hydrogen target with the beam momentum
of 1.92 GeV/. No peak structure corresponding to the mass was
observed. The upper limit of the production cross section averaged over the
scattering angle of 2 to 15 in the laboratory frame was
obtained to be 0.26 b/sr in the mass region of 1.511.55 GeV/.The
upper limit of the decay width using the effective Lagrangian
approach was obtained to be 0.72 MeV/ and 3.1 MeV/ for
and , respectively.Comment: 5 pages, 3 figures, 1 tabl
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large
spectrometer magnets of the PANDA detector set-up. It shows the conceptual
design of the magnets and their anticipated performance. It precedes the tender
and procurement of the magnets and, hence, is subject to possible modifications
arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti
Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski,
Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy),
Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy
- …
