75 research outputs found

    Computational and experimental characterization of intra-aortic balloon pump support

    Get PDF

    A method to increase the pulsatility in hemodynamic variables in an LVAD supported human circulation system

    Get PDF
    Left Ventricular Assist Devices (LVADs) generally operate at a constant speed in the human body. This causes a decrease in the pulsatility of hemodynamic variables. To increase the pulsatility a stepwise change was applied to the LVAD operating speed over a cardiac cycle. To do this, a numerical cardiovascular system model and a pump model were used. The model was developed by considering the static characteristics of the MicroMed DeBakey LVAD. First, the simulations were performed at constant operating speeds, 8500 rpm, 9500 rpm and 10500 rpm. Pulsatility indexes were calculated for left ventricular (LV) pressure, aortic pressure, LV volume and LVAD flow. Cardiac output (CO) was calculated at constant operating speed and these values used for comparing the pulsatility indexes with stepwise and constant operating speeds. The LVAD was operated at two different constant speeds in the stepwise operating speed simulations. Low and high operating speeds were adjusted so as to obtain the same cardiac output values with the constant operating speed simulations. The operating speeds in the simulations were 7800-11250 rpm, 9300-11250 rpm and 10300-11250 rpm. The same cardiac output values were obtained with an increase in the pulsatility of the hemodynamic variables without significant changes in their shapes except the LVAD flow. The obtained results show that it is possible to obtain more physiological results by applying a stepwise change to LVAD operating speed over a cardiac cycle

    New-Onset Atrial Fibrillation After PCI or CABG for Left Main Disease: The EXCEL Trial

    Get PDF
    Background: There is limited information on the incidence and prognostic impact of new-onset atrial fibrillation (NOAF) following percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) for left main coronary artery disease (LMCAD). Objectives: This study sought to determine the incidence of NOAF following PCI and CABG for LMCAD and its effect on 3-year cardiovascular outcomes. Methods: In the EXCEL (Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial, 1,905 patients with LMCAD and low or intermediate SYNTAX scores were randomized to PCI with everolimus-eluting stents versus CABG. Outcomes were analyzed according to the development of NOAF during the initial hospitalization following revascularization. Results: Among 1,812 patients without atrial fibrillation on presentation, NOAF developed at a mean of 2.7 ± 2.5 days after revascularization in 162 patients (8.9%), including 161 of 893 (18.0%) CABG-treated patients and 1 of 919 (0.1%) PCI-treated patients (p < 0.0001). Older age, greater body mass index, and reduced left ventricular ejection fraction were independent predictors of NOAF in patients undergoing CABG. Patients with versus without NOAF had a significantly longer duration of hospitalization, were more likely to be discharged on anticoagulant therapy, and had an increased 30-day rate of Thrombolysis In Myocardial Infarction major or minor bleeding (14.2% vs. 5.5%; p < 0.0001). By multivariable analysis, NOAF after CABG was an independent predictor of 3-year stroke (6.6% vs. 2.4%; adjusted hazard ratio [HR]: 4.19; 95% confidence interval [CI]: 1.74 to 10.11; p = 0.001), death (11.4% vs. 4.3%; adjusted HR: 3.02; 95% CI: 1.60 to 5.70; p = 0.0006), and the primary composite endpoint of death, MI, or stroke (22.6% vs. 12.8%; adjusted HR: 2.13; 95% CI: 1.39 to 3.25; p = 0.0004). Conclusions: In patients with LMCAD undergoing revascularization in the EXCEL trial, NOAF was common after CABG but extremely rare after PCI. The development of NOAF was strongly associated with subsequent death and stroke in CABG-treated patients. Further studies are warranted to determine whether prophylactic strategies to prevent or treat atrial fibrillation may improve prognosis in patients with LMCAD who are undergoing CABG. (Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularizatio

    Design, Analysis and Testing of a Novel Mitral Valve for Transcatheter Implantation

    Get PDF
    Mitral regurgitation is a common mitral valve dysfunction which may lead to heart failure. Because of the rapid aging of the population, conventional surgical repair and replacement of the pathological valve are often unsuitable for about half of symptomatic patients, who are judged high-risk. Transcatheter valve implantation could represent an effective solution. However, currently available aortic valve devices are inapt for the mitral position. This paper presents the design, development and hydrodynamic assessment of a novel bi-leaflet mitral valve suitable for transcatheter implantation. The device consists of two leaflets and a sealing component made from bovine pericardium, supported by a self-expanding wireframe made from superelastic NiTi alloy. A parametric design procedure based on numerical simulations was implemented to identify design parameters providing acceptable stress levels and maximum coaptation area for the leaflets. The wireframe was designed to host the leaflets and was optimised numerically to minimise the stresses for crimping in an 8 mm sheath for percutaneous delivery. Prototypes were built and their hydrodynamic performances were tested on a cardiac pulse duplicator, in compliance with the ISO5840-3:2013 standard. The numerical results and hydrodynamic tests show the feasibility of the device to be adopted as a transcatheter valve implant for treating mitral regurgitation

    Algorithmic Versus Expert Human Interpretation of Instantaneous Wave-Free Ratio Coronary Pressure-Wire Pull Back Data

    Get PDF
    Objectives The aim of this study was to investigate whether algorithmic interpretation (AI) of instantaneous wave-free ratio (iFR) pressure-wire pull back data would be noninferior to expert human interpretation. Background Interpretation of iFR pressure-wire pull back data can be complex and is subjective. Methods Fifteen human experts interpreted 1,008 iFR pull back traces (691 unique, 317 duplicate). For each trace, experts determined the hemodynamic appropriateness for percutaneous coronary intervention (PCI) and, in such cases, the optimal physiological strategy for PCI. The heart team (HT) interpretation was determined by consensus of the individual expert opinions. The same 1,008 pull back traces were also interpreted algorithmically. The coprimary hypotheses of this study were that AI would be noninferior to the interpretation of the median expert human in determining: 1) the hemodynamic appropriateness for PCI; and 2) the physiological strategy for PCI. Results Regarding the hemodynamic appropriateness for PCI, the median expert human demonstrated 89.3% agreement with the HT in comparison with 89.4% for AI (p < 0.01 for noninferiority). Across the 372 cases judged as hemodynamically appropriate for PCI according to the HT, the median expert human demonstrated 88.8% agreement with the HT in comparison with 89.7% for AI (p < 0.0001 for noninferiority). On reproducibility testing, the HT opinion itself changed 1 in 10 times for both the appropriateness for PCI and the physiological PCI strategy. In contrast, AI showed no change. Conclusions AI of iFR pressure-wire pull back data was noninferior to expert human interpretation in determining both the hemodynamic appropriateness for PCI and the optimal physiological strategy for PCI

    Vascular Remodeling in Health and Disease

    Get PDF
    The term vascular remodeling is commonly used to define the structural changes in blood vessel geometry that occur in response to long-term physiologic alterations in blood flow or in response to vessel wall injury brought about by trauma or underlying cardiovascular diseases.1, 2, 3, 4 The process of remodeling, which begins as an adaptive response to long-term hemodynamic alterations such as elevated shear stress or increased intravascular pressure, may eventually become maladaptive, leading to impaired vascular function. The vascular endothelium, owing to its location lining the lumen of blood vessels, plays a pivotal role in regulation of all aspects of vascular function and homeostasis.5 Thus, not surprisingly, endothelial dysfunction has been recognized as the harbinger of all major cardiovascular diseases such as hypertension, atherosclerosis, and diabetes.6, 7, 8 The endothelium elaborates a variety of substances that influence vascular tone and protect the vessel wall against inflammatory cell adhesion, thrombus formation, and vascular cell proliferation.8, 9, 10 Among the primary biologic mediators emanating from the endothelium is nitric oxide (NO) and the arachidonic acid metabolite prostacyclin [prostaglandin I2 (PGI2)], which exert powerful vasodilatory, antiadhesive, and antiproliferative effects in the vessel wall
    corecore