171 research outputs found

    Give Us A Chance: The Employment Experiences of New Settlers From East Asia

    Get PDF
    Our research on new settlers from Hong Kong, Taiwan and South Korea has revealed a general unhappiness with the lack of government planning and preparation to meet the needs of migrants who had been actively encouraged to come to New Zealand to help establish links with Asia. Over half had no paid employment in New Zealand. Among those who were currently employed, less than half had been able to obtain jobs related to their previous work experience and skills. Those who wished to do business were dissatisfied with the lack of information about business investment opportunities and the tax system. When it proved impossible to find appropriate employment or set up business in New Zealand in an effort to remain self-reliant, some immigrants chose to leave the family in New Zealand and return to work in their country of origin

    Give Us A Chance: The Employment Experiences of New Settlers From East Asia

    Get PDF
    Our research on new settlers from Hong Kong, Taiwan and South Korea has revealed a general unhappiness with the lack of government planning and preparation to meet the needs of migrants who had been actively encouraged to come to New Zealand to help establish links with Asia. Over half had no paid employment in New Zealand. Among those who were currently employed, less than half had been able to obtain jobs related to their previous work experience and skills. Those who wished to do business were dissatisfied with the lack of information about business investment opportunities and the tax system. When it proved impossible to find appropriate employment or set up business in New Zealand in an effort to remain self-reliant, some immigrants chose to leave the family in New Zealand and return to work in their country of origin

    In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

    Get PDF
    The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres

    Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    Full text link
    Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.Comment: 16 pages, 16 figure

    Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

    Full text link
    The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them. The 222^{222}Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry

    Multitarget Stool DNA Test Performance in an Average-Risk Colorectal Cancer Screening Population

    Get PDF
    INTRODUCTION: We set out to evaluate the performance of a multitarget stool DNA (MT-sDNA) in an average-risk colonoscopy-controlled colorectal cancer (CRC) screening population. MT-sDNA stool test results were evaluated against fecal immunochemical test (FIT) results for the detection of different lesions, including molecularly defined high-risk adenomas and several other tumor characteristics. METHODS: Whole stool samples (n = 1,047) were prospectively collected and subjected to an MT-sDNA test, which tests for KRAS mutations, NDRG4 and BMP3 promoter methylation, and hemoglobin. Results for detecting CRC (n = 7), advanced precancerous lesions (advanced adenoma [AA] and advanced serrated polyps; n = 119), and non-AAs (n = 191) were compared with those of FIT alone (thresholds of 50, 75, and 100 hemoglobin/mL). AAs with high risk of progression were defined by the presence of specific DNA copy number events as measured by low-pass whole genome sequencing. RESULTS: The MT-sDNA test was more sensitive than FIT alone in detecting advanced precancerous lesions (46% (55/119) vs 27% (32/119), respectively, P < 0.001). Specificities among individuals with nonadvanced or negative findings (controls) were 89% (791/888) and 93% (828/888) for MT-sDNA and FIT testing, respectively. A positive MT-sDNA test was associated with multiple lesions (P = 0.005), larger lesions (P = 0.03), and lesions with tubulovillous architecture (P = 0.04). The sensitivity of the MT-sDNA test or FIT in detecting individuals with high-risk AAs (n = 19) from individuals with low-risk AAs (n = 52) was not significantly different. DISCUSSION: In an average-risk screening population, the MT-sDNA test has an increased sensitivity for detecting advanced precancerous lesions compared with FIT alone. AAs with a high risk of progression were not detected with significantly higher sensitivity by MT-sDNA or FIT

    Design and construction of the DEAP-3600 dark matter detector

    Get PDF
    The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is 10−46cm2 for a 100 GeV/c2 WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector

    Offspring Hormones Reflect the Maternal Prenatal Social Environment: Potential for Foetal Programming?

    Get PDF
    Females of many species adaptively program their offspring to predictable environmental conditions, a process that is often mediated by hormones. Laboratory studies have shown, for instance, that social density affects levels of maternal cortisol and testosterone, leading to fitness-relevant changes in offspring physiology and behaviour. However, the effects of social density remain poorly understood in natural populations due to the difficulty of disentangling confounding influences such as climatic variation and food availability. Colonially breeding marine mammals offer a unique opportunity to study maternal effects in response to variable colony densities under similar ecological conditions. We therefore quantified maternal and offspring hormone levels in 84 Antarctic fur seals (Arctocephalus gazella) from two closely neighbouring colonies of contrasting density. Hair samples were used as they integrate hormone levels over several weeks or months and therefore represent in utero conditions during foetal development. We found significantly higher levels of cortisol and testosterone (both P < 0.001) in mothers from the high density colony, reflecting a more stressful and competitive environment. In addition, offspring testosterone showed a significant positive correlation with maternal cortisol (P < 0.05). Although further work is needed to elucidate the potential consequences for offspring fitness, these findings raise the intriguing possibility that adaptive foetal programming might occur in fur seals in response to the maternal social environment. They also lend support to the idea that hormonally mediated maternal effects may depend more strongly on the maternal regulation of androgen rather than cortisol levels
    corecore