556 research outputs found

    Application of superconducting coils to the NASA prototype magnetic balance

    Get PDF
    Application of superconducting coils to a general purpose magnetic balance was studied. The most suitable currently available superconducting cable for coils appears to be a bundle of many fine wires which are transposed and are mechanically confined. Sample coils were tested at central fields up to .5 Tesla, slewing rates up to 53 Tesla/ sec and frequencies up to 30 Hz. The ac losses were measured from helium boil-off and were approximately 20% higher than those calculated. Losses were dominated by hysteresis and a model for loss calculation which appears suitable for design purposes is presented along with computer listings. Combinations of two coils were also tested and interaction losses are reported. Two feasible geometries are also presented for prototype magnetic balance using superconductors

    Octupole strength in the neutron-rich calcium isotopes

    Full text link
    Low-lying excited states of the neutron-rich calcium isotopes 4852^{48-52}Ca have been studied via γ\gamma-ray spectroscopy following inverse-kinematics proton scattering on a liquid hydrogen target using the GRETINA γ\gamma-ray tracking array. The energies and strengths of the octupole states in these isotopes are remarkably constant, indicating that these states are dominated by proton excitations.Comment: 15 pages, 3 figure

    Cultural adaptation resources for nutrition and health in new immigrants in Central North Carolina.

    Get PDF
    This paper presents results of a study that was conducted for the purposes of describing available human services resources relating to nutrition, physical health, and behavioral health for new and recent immigrants (predominantly Mexican immigrants, but groups from Southeast Asia and continental Africa as well) in Guilford County, NC. Sixty-five service providers were determined to represent cultural adaptation resources providing either direct and/or ancillary assistance to limited English proficient immigrants. Seventeen direct assistance providers specialized in food and nutrition programs, but only 2 had targeted programs for addressing food scarcity, insecurity, and nutritional deficiencies in immigrant households. Four of 15 direct physical health services providers had clinical care or specialty programs for immigrants. Finally, 5 of 16 direct behavioral health care providers offered mental health treatment and counseling services adapted specifically for targeted immigrant groups. These findings highlight the limited development of the existing human services network to increase its capacity to provide nutrition and health related services to a growing community of diverse immigrant groups. These descriptive results underscore a need for additional local level or community based resources to be directed towards increasing the community’s ability to provide essential human services to population groups not yet language proficient and acculturated to “American community standards.

    SPECT/CT imaging of the lumbar spine in chronic low back pain: a case report

    Get PDF
    Mechanical low back pain is a common indication for Nuclear Medicine imaging. Whole-body bone scan is a very sensitive but poorly specific study for the detection of metabolic bone abnormalities. The accurate localisation of metabolically active bone disease is often difficult in 2D imaging but single photon emission computed tomography/computed tomography (SPECT/CT) allows accurate diagnosis and anatomic localisation of osteoblastic and osteolytic lesions in 3D imaging. We present a clinical case of a patient referred for evaluation of chronic lower back pain with no history of trauma, spinal surgery, or cancer. Planar whole-body scan showed heterogeneous tracer uptake in the lumbar spine with intense localisation to the right lateral aspect of L3. Integrated SPECT/CT of the lumbar spine detected active bone metabolism in the right L3/L4 facet joint in the presence of minimal signs of degenerative osteoarthrosis on CT images, while a segment demonstrating more gross degenerative changes was more quiescent with only mild tracer uptake. The usefulness of integrated SPECT/CT for anatomical and functional assessment of back pain opens promising opportunities both for multi-disciplinary clinical assessment and treatment for manual therapists and for research into the effectiveness of manual therapies

    The effect of airfoil scaling on the predicted unsteady loading onthe blade of a 1 and 1/2 stage transonic turbine and a comparison with experimental results

    Get PDF
    ABSTRACT In this study, two time-accurate Navier-Stokes analyses were obtained to predict the first-vane/first-blade interaction in a 1 and 1/2-stage turbine rig for comparison with measurements. In the first computation, airfoil scaling was applied to the turbine blade to achieve periodicity in the circumferential direction while modeling 1/18 of the annulus. In the second, 1/4 of the wheel was modeled without the use of airfoil scaling. For both simulations the predicted unsteady pressures on the blade were similar in terms of time-averaged pressure distributions and peak-peak unsteady pressure envelopes. However, closer inspection of the predictions in the frequency domain revealed significant differences in the magnitudes of unsteadiness at twice vane-passing frequency (and the vane-passing frequency itself, to a lesser extent). The results of both computations were compared to measurements of the vane-blade interaction in a full-scale turbine rig representative of an early design iteration of the PW6000 engine. These measurements were made in the short-duration turbine-test facility at The Ohio State University Gas Turbine Laboratory. The experimentally determined, time-resolved pressures were in good agreement with those predicted with the 1/4-wheel simulation

    Symptomatic reactions, clinical outcomes and patient satisfaction associated with upper cervical chiropractic care: A prospective, multicenter, cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Observational studies have previously shown that adverse events following manipulation to the neck and/or back are relatively common, although these reactions tend to be mild in intensity and self-limiting. However, no prospective study has examined the incidence of adverse reactions following spinal adjustments using upper cervical techniques, and the impact of this care on clinical outcomes.</p> <p>Methods</p> <p>Consecutive new patients from the offices of 83 chiropractors were recruited for this practice-based study. Clinical outcome measures included 1) Neck pain disability index (100-point scale), 2) Oswestry back pain index (100-point scale), 3) 11-point numerical rating scale (NRS) for neck, headache, midback, and low back pain, 4) treatment satisfaction, and 5) Symptomatic Reactions (SR). Data were collected at baseline, and after approximately 2 weeks of care. A patient reaching sub-clinical status for pain and disability was defined as a follow-up score <3 NRS and <10%, respectively. A SR is defined as a new complaint not present at baseline or a worsening of the presenting complaint by >30% based on an 11-point numeric rating scale occurring <24 hours after any upper cervical procedure.</p> <p>Results</p> <p>A total of 1,090 patients completed the study having 4,920 (4.5 per patient) office visits requiring 2,653 (2.4 per patient) upper cervical adjustments over 17 days. Three hundred thirty- eight (31.0%) patients had SRs meeting the accepted definition. Intense SR (NRS ≥8) occurred in 56 patients (5.1%). Outcome assessments were significantly improved for neck pain and disability, headache, mid-back pain, as well as lower back pain and disability (<it>p </it><0.001) following care with a high level (mean = 9.1/10) of patient satisfaction. The 83 chiropractors administered >5 million career upper cervical adjustments without a reported incidence of serious adverse event.</p> <p>Conclusions</p> <p>Upper cervical chiropractic care may have a fairly common occurrence of mild intensity SRs short in duration (<24 hours), and rarely severe in intensity; however, outcome assessments were significantly improved with less than 3 weeks of care with a high level of patient satisfaction. Although our findings need to be confirmed in subsequent randomized studies for definitive risk-benefit assessment, the preliminary data shows that the benefits of upper cervical chiropractic care may outweigh the potential risks.</p

    Current understanding of the relationship between cervical manipulation and stroke: what does it mean for the chiropractic profession?

    Get PDF
    The understanding of the relationship between cervical manipulative therapy (CMT) and vertebral artery dissection and stroke (VADS) has evolved considerably over the years. In the beginning the relationship was seen as simple cause-effect, in which CMT was seen to cause VADS in certain susceptible individuals. This was perceived as extremely rare by chiropractic physicians, but as far more common by neurologists and others. Recent evidence has clarified the relationship considerably, and suggests that the relationship is not causal, but that patients with VADS often have initial symptoms which cause them to seek care from a chiropractic physician and have a stroke some time after, independent of the chiropractic visit

    New Results from the Cryogenic Dark Matter Search Experiment

    Full text link
    Using improved Ge and Si detectors, better neutron shielding, and increased counting time, the Cryogenic Dark Matter Search (CDMS) experiment has obtained stricter limits on the cross section of weakly interacting massive particles (WIMPs) elastically scattering from nuclei. Increased discrimination against electromagnetic backgrounds and reduction of neutron flux confirm WIMP-candidate events previously detected by CDMS were consistent with neutrons and give limits on spin-independent WIMP interactions which are >2X lower than previous CDMS results for high WIMP mass, and which exclude new parameter space for WIMPs with mass between 8-20 GeV/c^2.Comment: 4 pages, 4 figure
    corecore