771 research outputs found
Measurements and optimization of the light yield of a TeO crystal
Bolometers have proven to be good instruments to search for rare processes
because of their excellent energy resolution and their extremely low intrinsic
background. In this kind of detectors, the capability of discriminating alpha
particles from electrons represents an important aspect for the background
reduction. One possibility for obtaining such a discrimination is provided by
the detection of the Cherenkov light which, at the low energies of the natural
radioactivity, is only emitted by electrons. This paper describes the method
developed to evaluate the amount of light produced by a crystal of TeO when
hit by a 511 keV photon. The experimental measurements and the results of a
detailed simulation of the crystal and the readout system are shown and
compared. A light yield of about 52 Cherenkov photons per deposited MeV was
measured. The effect of wrapping the crystal with a PTFE layer, with the aim of
maximizing the light collection, is also presented
New experimental limits on the alpha decays of lead isotopes
For the first time a PbWO4 crystal was grown using ancient Roman lead and it
was run as a cryogenic detector. Thanks to the simultaneous and independent
read-out of heat and scintillation light, the detector was able to discriminate
beta/gamma interactions with respect to alpha particles down to low energies.
New more stringent limits on the alpha decays of the lead isotopes are
presented. In particular a limit of T_{1/2} > 1.4*10^20 y at a 90% C.L. was
evaluated for the alpha decay of 204Pb to 200Hg
New application of superconductors: high sensitivity cryogenic light detectors
In this paper we describe the current status of the CALDER project, which is
developing ultra-sensitive light detectors based on superconductors for
cryogenic applications. When we apply an AC current to a superconductor, the
Cooper pairs oscillate and acquire kinetic inductance, that can be measured by
inserting the superconductor in a LC circuit with high merit factor.
Interactions in the superconductor can break the Cooper pairs, causing sizable
variations in the kinetic inductance and, thus, in the response of the LC
circuit. The continuous monitoring of the amplitude and frequency modulation
allows to reconstruct the incident energy with excellent sensitivity. This
concept is at the basis of Kinetic Inductance Detectors (KIDs), that are
characterized by natural aptitude to multiplexed read-out (several sensors can
be tuned to different resonant frequencies and coupled to the same line),
resolution of few eV, stable behavior over a wide temperature range, and ease
in fabrication. We present the results obtained by the CALDER collaboration
with 2x2 cm2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the
performances of the first prototypes are already competitive with those of
other commonly used light detectors, and we discuss the strategies for a
further improvement
Characterization of the KID-Based Light Detectors of CALDER
The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution
(CALDER) project is the development of light detectors with active area of
cm and noise energy resolution smaller than 20 eV RMS,
implementing phonon-mediated kinetic inductance detectors. The detectors are
developed to improve the background suppression in large-mass bolometric
experiments such as CUORE, via the double read-out of the light and the heat
released by particles interacting in the bolometers. In this work, we present
the characterization of the first light detectors developed by CALDER. We
describe the analysis tools to evaluate the resonator parameters (resonant
frequency and quality factors) taking into account simultaneously all the
resonance distortions introduced by the read-out chain (as the feed-line
impedance and its mismatch) and by the power stored in the resonator itself. We
detail the method for the selection of the optimal point for the detector
operation (maximizing the signal-to-noise ratio). Finally, we present the
response of the detector to optical pulses in the energy range of 0-30 keV
Development of a Li2MoO4 scintillating bolometer for low background physics
We present the performance of a 33 g Li2MoO4 crystal working as a
scintillating bolometer. The crystal was tested for more than 400 h in a
dilution refrigerator installed in the underground laboratory of Laboratori
Nazionali del Gran Sasso (Italy). This compound shows promising features in the
frame of neutron detection, dark matter search (solar axions) and neutrinoless
double-beta decay physics. Low temperature scintillating properties were
investigated by means of different alpha, beta/gamma and neutron sources, and
for the first time the Light Yield for different types of interacting particle
is estimated. The detector shows great ability of tagging fast neutron
interactions and high intrinsic radiopurity levels (< 90 \muBq/kg for 238-U and
< 110 \muBq/kg for 232-Th).Comment: revised versio
High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
The development of wide-area cryogenic light detectors with good energy
resolution is one of the priorities of next generation bolometric experiments
searching for rare interactions, as the simultaneous read-out of the light and
heat signals enables background suppression through particle identification.
Among the proposed technological approaches for the phonon sensor, the
naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their
excellent intrinsic energy resolution and reproducibility. To satisfy the large
surface requirement (several cm) KIDs are deposited on an insulating
substrate that converts the impinging photons into phonons. A fraction of
phonons is absorbed by the KID, producing a signal proportional to the energy
of the original photons. The potential of this technique was proved by the
CALDER project, that reached a baseline resolution of 1547 eV RMS by
sampling a 22 cm Silicon substrate with 4 Aluminum KIDs. In this
paper we present a prototype of Aluminum KID with improved geometry and quality
factor. The design improvement, as well as the combined analysis of amplitude
and phase signals, allowed to reach a baseline resolution of 824 eV by
sampling the same substrate with a single Aluminum KID
First bolometric measurement of the two neutrino double beta decay of Mo with a ZnMoO crystals array
The large statistics collected during the operation of a ZnMoO array, for
a total exposure of 1.3 kg day of Mo, allowed the first
bolometric observation of the two neutrino double beta decay of Mo. The
observed spectrum of each crystal was reconstructed taking into account the
different background contributions due to environmental radioactivity and
internal contamination. The analysis of coincidences between the crystals
allowed the assignment of constraints to the intensity of the different
background sources, resulting in a reconstruction of the measured spectrum down
to an energy of 300 keV. The half-life extracted from the data is
T= [7.15 0.37 (stat) 0.66 (syst)] 10
y.Comment: 6 pages, 2 figure, Accepted for publication in Journal of Physics G:
Nuclear and Particle Physic
CALDER - Neutrinoless double-beta decay identification in TeO bolometers with kinetic inductance detectors
Next-generation experiments searching for neutrinoless double-beta decay must
be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of
988 TeO bolometers being commissioned at Laboratori Nazionali del Gran
Sasso in Italy, features an expected sensitivity of 50-130 meV at 90% C.L, that
can be improved by removing the background from radioactivity. This is
possible if, in coincidence with the heat release in a bolometer, the Cherenkov
light emitted by the signal is detected. The amount of light detected
is so far limited to only 100 eV, requiring low-noise cryogenic light
detectors. The CALDER project (Cryogenic wide-Area Light Detectors with
Excellent Resolution) aims at developing a small prototype experiment
consisting of TeO bolometers coupled to new light detectors based on
kinetic inductance detectors. The R&D is focused on the light detectors that
could be implemented in a next-generation neutrinoless double-beta decay
experiment.Comment: 8 pages, 3 figures, added reference to first result
- …
