290 research outputs found
Optimum Design of Organic Electrochemical Type Transistors for Applications in Biochemical Sensing
This paper addresses the issue of optimizing various performance parameters involved in the design of organic electrochemical type transistors based on the conducting polymer, polyâ(3,4-ethylenedioxythiophene): poly(styrene sulfonate)(PEDOT:PSS) for applications in biochemical sensing. We report the effect of device contact geometry, gate to channel length ratio âLg/L,â and analyte distance from the source electrode âx,â on the device sensitivity and response time
Absolute rigidity spectrum of protons and helium nuclei above 10 GV/c
Proton and helium nuclei differential spectra were gathered with a balloon borne magnet spectrometer. The data were fitted to the assumption that the differential flux can be represented by a power law in rigidity. In the rigidity range 10 to 25 GV/c the spectral indices were found to be -(2.74 plus or minus 0.04) for protons and -(2.71 plus or minus 0.05) for helium nuclei. A brief discussion is given by systematic errors
Observation of cosmic ray positrons from 5 to 25 GeV
The positron data gathered in conjunction with electron data published elsewhere is reported. The basic recognition scheme was to look for low mass positive particles that cause a cascade in a 7 radiation length shower counter. The mass criteria is imposed by selecting particles that were accompanied by Cherenkov light but whose rigidity was below the proton Cherenkov threshold. Thus the proton Cherenkov threshold represents an upper limit to the range of the experiment
Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study).
BackgroundTransseptal puncture is a critical step in achieving left atrial (LA) access for a variety of cardiac procedures. Although the mechanical Brockenbrough needle has historically been used for this procedure, a needle employing radiofrequency (RF) energy has more recently been approved for clinical use. We sought to investigate the comparative effectiveness of an RF versus conventional needle for transseptal LA access.Methods and resultsIn this prospective, single-blinded, controlled trial, 72 patients were randomized in a 1:1 fashion to an RF versus conventional (BRK-1) transseptal needle. In an intention-to-treat analysis, the primary outcome was time required for transseptal LA access. Secondary outcomes included failure of the assigned needle, visible plastic dilator shavings from needle introduction, and any procedural complication. The median transseptal puncture time was 68% shorter using the RF needle compared with the conventional needle (2.3 minutes [interquartile range {IQR}, 1.7 to 3.8 minutes] versus 7.3 minutes [IQR, 2.7 to 14.1 minutes], P = 0.005). Failure to achieve transseptal LA access with the assigned needle was less common using the RF versus conventional needle (0/36 [0%] versus 10/36 [27.8%], P < 0.001). Plastic shavings were grossly visible after needle advancement through the dilator and sheath in 0 (0%) RF needle cases and 12 (33.3%) conventional needle cases (P < 0.001). There were no differences in procedural complications (1/36 [2.8%] versus 1/36 [2.8%]).ConclusionsUse of an RF needle resulted in shorter time to transseptal LA access, less failure in achieving transseptal LA access, and fewer visible plastic shavings
Radio-emitting electrons and cosmic ray confinement
The propagation of cosmic ray electrons in the framework of the Disk-Halo diffusion model in which the diffusion coefficientD ∝ z δ E μ (where z is the distance from the galactic plane and E is the energy), and the magnetic field H∝z - ξ has been examined by making use of the recently available radio data up to 8 GHz toward the anticenter (A) and halo minimum (M). The following inferences are then made. From the difference in the frequency at which steepening occurs in the radio spectra toward A and H, it is found that the observations are consistent with the magnetic field decreasing with z such that ξ=0.24-0.37. An electron injection spectrum with a single power law down to energies well below 1 GeV cannot explain satisfactorily the observed radio spectra. All observations, however, can be understood in a self consistent way if the observed steepening of the radio spectra, and hence the interstellar electron spectrum, is due partly to the deviation in the power law electron injection spectrum below a few GeV and partly to the first break arising from electron energy losses occurring in the same energy region. In this case, using the value of ξ obtained above and a value of μ=0.3-0.6, it is found that the spectral index γ 0 of the injected electrons above a few GeV has a value between 1.9 and 2.3 and the index δ a value between 0.5 and 1. Further, if the electrons and protons have the same spectral shape at injection, then γ 0=2.1-2.3
Sex Differences in the Utilization and Outcomes of Surgical Aortic Valve Replacement for Severe Aortic Stenosis
Background
Studies assessing the differential impact of sex on outcomes of aortic valve replacement (AVR) yielded conflicting results. We sought to investigate sexârelated differences in AVR utilization, patient risk profile, and inâhospital outcomes using the Nationwide Inpatient Sample. Methods and Results
In total, 166 809 patients (63% male and 37% female) who underwent AVR between 2003 and 2014 were identified, and 48.5% had a concomitant cardiac surgery procedure. Compared with men, women were older and had more nonatherosclerotic comorbid conditions including hypertension, diabetes mellitus, obstructive pulmonary disease, atrial fibrillation/flutter, and anemia but fewer incidences of coronary and peripheral arterial disease and prior sternotomies. Inâhospital mortality was significantly higher in women (5.6% versus 4%, P\u3c0.001). Propensity matching was performed to assess the impact of sex on the outcomes of isolated AVR and yielded 28 237 matched pairs of male and female participants. In the propensityâmatched groups, inâhospital mortality was higher in women (3.3% versus 2.9%, P\u3c0.001). Along with vascular complications and blood transfusion (6% versus 5.6%, P=0.027 and 40.4% versus 33.9%, P\u3c0.001, respectively). Rates of stroke, permanent pacemaker implantation, and acute kidney injury requiring dialysis were similar (2.4% versus 2.4%, P=0.99; 6% versus 6.3%, P=0.15; and 1.4% versus 1.3%, P=0.14, respectively). Length of stay median and interquartile range were both similar between groups (7±6 days). Rates of nonhome discharge were higher among women (27.9% versus 19.6%, P\u3c0.001). Conclusions
Women have worse inâhospital mortality following AVR compared with men. Coupled with the accumulating evidence suggesting higher magnitude of benefit of transcatheter AVR over AVRin women, women should perhaps be offered transcatheter AVR over AVR at a lower threshold than men
Changing trends in pseudoretinoblastoma diagnoses: A 10 year review from the United Kingdom
AIM:To study the different types and frequency of pseudoretinoblastoma (pseudoRB) lesions who present to a retinoblastoma centre due to concern that the condition may be retinoblastoma.
METHODS: A retrospective chart review of 341 patients presenting sporadically to the Royal London Hospital from January 2009 to December 2018. RESULTS: 220 patients (65%) were confirmed to have retinoblastoma, while 121 (35%) had pseudoRB. There were 23 differential diagnoses in total. The top 3 differential diagnoses were Coatsâ disease (34%), Persistent Foetal Vasculature (PFV) (17%) and Combined Hamartoma of Retina and Retinal Pigment Epithelium (CHR-RPE) (13%). PseudoRBs differed with age at presentation. Under the age of 1 (nâ=â42), the most likely pseudoRB conditions were PFV (36%), Coatsâ disease (17%) and CHR-RPE (12%). These conditions were also the most common simulating conditions between the ages of 1 and 2 (nâ=â21), but Coatsâ disease was the most common in this age group (52%), followed by CHR-RPE (19%) and PFV (14%). Between the ages of 2 and 5 (nâ=â32), Coatsâ disease remained the most common (44%) pseudoRB lesion followed by CHR-RPE (13%), or PFV, Retinal Astrocytic Hamartoma (RAH), familial exudative vitreoretinopathy (FEVR) (all 6.3%). Over the age of 5 (nâ=â26), pseudoRBs were most likely to be Coatsâ disease (35%), RAH (12%), Uveitis, CHR-RPE, FEVR (all 7.7%). CONCLUSION: 35% of suspected retinoblastoma cases are pseudoRB conditions. Overall, Coatsâ disease is the most common pseudoRB condition, followed by PFV. Hamartomas (CHR-RPE & RAH) are more prevalent in this cohort, reflecting improvements in diagnostic accuracy from referring ophthalmologists
Parametrizations of Inclusive Cross Sections for Pion Production in Proton-Proton Collisions
Accurate knowledge of cross sections for pion production in proton-proton
collisions finds wide application in particle physics, astrophysics, cosmic ray
physics and space radiation problems, especially in situations where an
incident proton is transported through some medium, and one requires knowledge
of the output particle spectrum given the input spectrum. In such cases
accurate parametrizations of the cross sections are desired. In this paper we
review much of the experimental data and compare to a wide variety of different
cross section parametrizations. In so doing, we provide parametrizations of
neutral and charged pion cross sections which provide a very accurate
description of the experimental data. Lorentz invariant differential cross
sections, spectral distributions and total cross section parametrizations are
presented.Comment: 32 pages with 15 figures. Published in Physical Review D62, 094030.
File includes 6 tex files. The main file is paper.tex which has include
statements refering to the rest. figures are in graphs.di
Measurement of the flux of atmospheric muons with the CAPRICE94 apparatus
A new measurement of the momentum spectra of both positive and negative muons
as function of atmospheric depth was made by the balloon-borne experiment
CAPRICE94. The data were collected during ground runs in Lynn Lake on the
19-20th of July 1994 and during the balloon flight on the 8-9th of August 1994.
We present results that cover the momentum intervals 0.3-40 GeV/c for negative
muons and 0.3-2 GeV/c for positive muons, for atmospheric depths from 3.3 to
1000 g/cm**2, respectively. Good agreement is found with previous measurements
for high momenta, while at momenta below 1 GeV/c we find latitude dependent
geomagnetic effects. These measurements are important cross-checks for the
simulations carried out to calculate the atmospheric neutrino fluxes and to
understand the observed atmospheric neutrino anomaly.Comment: 28 pages, 13 Postscript figures, uses revtex.sty, to appear in Phys.
Rev.