28 research outputs found

    Inappropriate cardioverter-defibrillator discharge continues to be a major problem in clinical practice

    Get PDF
    Background: The purpose of this study was to determine the rate and causes of inappropriate rhythm detection, and to compare adequacy of ventricular arrhythmia detection by single-chamber and dual-chamber cardioverter-defibrillators (ICD). Methods: We evaluated 190 patients (age 57.2 ± 11.2 years) with ICD. Follow-up: 34.3 ± ± 22 months. Dual-chamber ICD was used in 54 patients. Results: We evaluated 2244 arrhythmia events recognized as of ventricular origin, including ventricular tachycardia and ventricular fibrillation. 431 events (19.2%) were recognized erroneously and resulted in an inappropriate ICD discharge. Most cases of inappropriate therapies (182 events, 42.23%) were due to atrial fibrillation or flutter. Overall, inappropriate arrhythmia detection was found in 64 (33.6%) of 190 patients. In terms of the number of affected patients, the most common cause of inappropriate ICD discharge was sinus tachycardia - 23 (12.1%) patients, followed by atrial fibrillation - 16 (8.4%) patients. Among 54 patients with dual-chamber ICD, inappropriate therapy was noted in 21 (38.8%) patients, (T wave oversensing, sinus tachycardia and atrial fibrillation etc.). No significant difference was seen in the rate of inappropriate therapy due to a rapid supraventricular rhythm between patients with single-chamber versus dual-chamber ICD. In contrast, patients with single-chamber ICD more often experienced inappropriate therapy due to atrial fibrillation (155 vs. 28 patients) and sinus tachycardia (66 vs. 9 patients). Conclusions: Despite of introduction of new generations of ICDs, the problem of inappropriate ICD discharge could not be eliminated. The major problem is distinction between supraventricular arrhythmia and ventricular tachyarrhythmia

    Cz臋stoskurcz komorowy p臋czkowy u pacjenta z chorob膮 niedokrwienn膮 serca w starszym wieku

    Get PDF
    Cz臋stoskurcz p臋czkowy to rzadka posta膰 cz臋stoskurczu komorowego pochodz膮cego z lewej komory, kt贸ra wyst臋puje najcz臋艣ciej u m艂odych os贸b bez strukturalnej choroby serca. Ma morfologi臋 bloku prawej odnogi p臋czka Hisa z lewogramem. W pracy przedstawiono przypadek starszego pacjenta z chorob膮 wie艅cow膮, u kt贸rego wyst膮pi艂 cz臋stoskurcz komorowy o elektrokardiograficznych i klinicznych cechach cz臋stoskurczu p臋czkowego. W przerywaniu napad贸w skuteczny okaza艂 si臋 werapamil. Rewaskularyzacja przezsk贸rna wykonana z powodu istotnych zw臋偶e艅 prawej t臋tnicy wie艅cowej i t臋tnicy diagonalnej pierwszej nie spowodowa艂a wyt艂umienia arytmii. U pacjenta wykonano ablacj臋 pr膮dem o wysokiej cz臋stotliwo艣ci pod艂o偶a arytmii w okolicy tylno-dolnej lewej komory. Po ablacji nie indukowano cz臋stoskurczu komorowego, nawet przy wlewie izoprenaliny, nie obserwowano r贸wnie偶 nawrot贸w w 24-miesi臋cznej obserwacji. W pracy podj臋to tak偶e temat diagnostyki r贸偶nicowej cz臋stoskurczu „idiopatycznego” z cz臋stoskurczem na tle choroby niedokrwiennej serca. (Folia Cardiol. 2004; 11: 57–60

    Cz臋stoskurcz komorowy p臋czkowy u pacjenta z chorob膮 niedokrwienn膮 serca w starszym wieku

    Get PDF
    Cz臋stoskurcz p臋czkowy to rzadka posta膰 cz臋stoskurczu komorowego pochodz膮cego z lewej komory, kt贸ra wyst臋puje najcz臋艣ciej u m艂odych os贸b bez strukturalnej choroby serca. Ma morfologi臋 bloku prawej odnogi p臋czka Hisa z lewogramem. W pracy przedstawiono przypadek starszego pacjenta z chorob膮 wie艅cow膮, u kt贸rego wyst膮pi艂 cz臋stoskurcz komorowy o elektrokardiograficznych i klinicznych cechach cz臋stoskurczu p臋czkowego. W przerywaniu napad贸w skuteczny okaza艂 si臋 werapamil. Rewaskularyzacja przezsk贸rna wykonana z powodu istotnych zw臋偶e艅 prawej t臋tnicy wie艅cowej i t臋tnicy diagonalnej pierwszej nie spowodowa艂a wyt艂umienia arytmii. U pacjenta wykonano ablacj臋 pr膮dem o wysokiej cz臋stotliwo艣ci pod艂o偶a arytmii w okolicy tylno-dolnej lewej komory. Po ablacji nie indukowano cz臋stoskurczu komorowego, nawet przy wlewie izoprenaliny, nie obserwowano r贸wnie偶 nawrot贸w w 24-miesi臋cznej obserwacji. W pracy podj臋to tak偶e temat diagnostyki r贸偶nicowej cz臋stoskurczu „idiopatycznego” z cz臋stoskurczem na tle choroby niedokrwiennej serca. (Folia Cardiol. 2004; 11: 57–60

    B艂臋dne interwencje lecznicze kardiowerter贸w-defibrylator贸w - nadal istotny problem kliniczny

    Get PDF
    Wst臋p: Jednym z wa偶niejszych problem贸w, jakie dotycz膮 pracy kardiowerter贸w-defibrylator贸w (ICD), s膮 nieadekwatne terapie. Szczeg贸lnie dotyczy to pacjent贸w, u kt贸rych wyst臋puj膮 tachyarytmie nadkomorowe. Celem pracy by艂o okre艣lenie cz臋sto艣ci i przyczyn wyst臋powania zaburze艅 detekcji, a tak偶e por贸wnanie adekwatno艣ci detekcji arytmii komorowych w ICD jedno- i dwujamowych, ze szczeg贸lnym uwzgl臋dnieniem wsp贸艂wyst臋powania arytmii nadkomorowych. Metody: Analizie poddano 190 os贸b (36 kobiet i 154 m臋偶czyzn, w 艣rednim wieku 57,2 ± 11,2 roku), kt贸rym wszczepiono ICD. 艢redni czas obserwacji wyni贸s艂 34,3 ± 22 miesi膮ce. U 136 pacjent贸w implantowano ICD jednojamowy, u 54 - dwujamowy. Wyniki: Przeanalizowano 艂膮cznie 2233 epizody okre艣lone jako komorowe (VT, VF). Ustalono, 偶e 431 (ok. 19,2%) epizod贸w by艂o rozpoznanych nieprawid艂owo i doprowadzi艂o do nieadekwatnej reakcji ICD. Najwi臋cej nieadekwatnych terapii, 182 (42,23%), wyst膮pi艂o z powodu migotania b膮d藕 trzepotania przedsionk贸w, 66 (15,31%) - tachykardii zatokowej, 66 (15,31%) - zaburze艅 czucia o charakterze oversensingu sygna艂u innego ni偶 za艂amek T, 61 (14,15%) - oversensingu fali T, 40 (9,28%) - uszkodzenia elektrody, 11 (2,56%) - slow VT, 3 (0,7%) - nieutrwalonego VT, 2 (0,46%) - cz臋stoskurczu nadkomorowego. W grupie 190 pacjent贸w zaburzenia detekcji wyst膮pi艂y u 64 (ok. 33,6%) os贸b. Najcz臋stsz膮 przyczyn膮 nieadekwatnej terapii - pod wzgl臋dem liczby os贸b, kt贸re je do艣wiadczy艂y - by艂a tachykardia zatokowa. Zjawisko to wyst膮pi艂o u 23 (12,1%) pacjent贸w. Migotanie przedsionk贸w stwierdzono u 16 (8,4%) chorych. W艣r贸d 54 pacjent贸w, kt贸rym implantowano urz膮dzenie dwujamowe, nieadekwatnych terapii do艣wiadczy艂o 21 (38,8%), a najcz臋stszym powodem okaza艂y si臋 sterowanie za艂amkiem T, tachykardia zatokowa oraz migotanie przedsionk贸w. Wyniki por贸wnania odsetk贸w os贸b, kt贸re do艣wiadczy艂y nieadekwatnych terapii zwi膮zanych z szybkimi rytmami nadkomorowymi, w grupie pacjent贸w z jednojamowym ICD i chorych z dwujamowym urz膮dzeniem, wskazuj膮 na brak istotnych r贸偶nic mi臋dzy nimi. Natomiast w przypadku liczby epizod贸w znacznie wi臋cej nieadekwatnych terapii z powodu migotania przedsionk贸w (155 v. 28) i tachykardii zatokowej (66 v. 9) zaobserwowano w grupie os贸b z jednojamowym ICD. Wnioski: Przez ponad 20 lat, mimo wprowadzania kolejnych generacji urz膮dze艅 (w tym dwujamowych ICD) oraz stosowania coraz bardziej wyszukanych algorytm贸w analizuj膮cych sygna艂y pochodz膮ce z serca, nie uda艂o si臋 wyeliminowa膰 zjawiska nieadekwatnych terapii. Tachykardia zatokowa oraz migotanie lub trzepotanie przedsionk贸w stanowi膮 najwi臋kszy problem dla ICD w r贸偶nicowaniu z tachyarytmiami komorowymi. Folia Cardiologica Excerpta 2010; 5, 1: 38-4

    Effect of Sodium Fluoride Ingestion on Malondialdehyde Concentration and the Activity of Antioxidant Enzymes in Rat Erythrocytes

    Get PDF
    Fluoride intoxication has been shown to produce diverse deleterious metabolic alterations within the cell. To determine the effects of sodium fluoride (NaF) treatment on malondialdehyde (MDA) levels and on the activity of antioxidant enzymes in rat erythrocytes, Male Wistar rats were treated with 50 ppm of NaF or were untreated as controls. Erythrocytes were obtained from rats sacrificed weekly for up to eight weeks and the concentration of MDA in erythrocyte membrane was determined. In addition, the activity of the enzymes superoxide, dismutase, catalase, and glutathione peroxidase were determined. Treatment with NaF produces an increase in the concentration of malondialdehyde in the erythrocyte membrane only after the eight weeks of treatment. On the other hand, antioxidant enzyme activity was observed to increase after the fourth week of NaF treatment. In conclusion, intake of NaF produces alterations in the erythrocyte of the male rat, which indicates induction of oxidative stress

    A prospective survey in European Society of Cardiology member countries of atrial fibrillation management: baseline results of EURO bservational Research Programme Atrial Fibrillation (EORP-AF) Pilot General Registry

    Get PDF
    Aims: Given the advances in atrial fibrillation (AF) management and the availability of new European Society of Cardiology (ESC) guidelines, there is a need for the systematic collection of contemporary data regarding the management and treatment of AF in ESC member countries. Methods and results: We conducted a registry of consecutive in- and outpatients with AF presenting to cardiologists in nine participating ESC countries. All patients with an ECG-documented diagnosis of AF confirmed in the year prior to enrolment were eligible. We enroled a total of 3119 patients from February 2012 to March 2013, with full data on clinical subtype available for 3049 patients (40.4% female; mean age 68.8 years). Common comorbidities were hypertension, coronary disease, and heart failure. Lone AF was present in only 3.9% (122 patients). Asymptomatic AF was common, particularly among those with permanent AF. Amiodarone was the most common antiarrhythmic agent used (~20%), while beta-blockers and digoxin were the most used rate control drugs. Oral anticoagulants (OACs) were used in 80% overall, most often vitamin K antagonists (71.6%), with novel OACs being used in 8.4%. Other antithrombotics (mostly antiplatelet therapy, especially aspirin) were still used in one-third of the patients, and no antithrombotic treatment in only 4.8%. Oral anticoagulants were used in 56.4% of CHA 2DS2-VASc = 0, with 26.3% having no antithrombotic therapy. A high HAS-BLED score was not used to exclude OAC use, but there was a trend towards more aspirin use in the presence of a high HAS-BLED score. Conclusion: The EURObservational Research Programme Atrial Fibrillation (EORP-AF) Pilot Registry has provided systematic collection of contemporary data regarding the management and treatment of AF by cardiologists in ESC member countries. Oral anticoagulant use has increased, but novel OAC use was still low. Compliance with the treatment guidelines for patients with the lowest and higher stroke risk scores remains suboptimal. 漏 The Author 2013

    Artyku艂 oryginalnyPonowne hospitalizacje pacjent贸w z implantowanym kardiowerterem-defibrylatorem serca

    No full text
    Introduction: Hospital readmissions are one of the important problems of patients with implantable cardioverter-defibrillators (ICD). Detailed analysis of the causes of rehospitalisations may lead to improved management of ICD patients and eventually limit the number of hospital readmissions. Aim: Prospective analysis of repeat hospitalisations, their causes and time from discharge to first hospital readmission in a group of patients after ICD implantation. A search for predictors of rehospitalisation was also performed. Methods: Analysis involved 133 consecutive patients who underwent ICD implantation in the Department of Cardiology, PAM. Readmission causes were split into cardiac and non-cardiac. An index of repeat hospitalisation was calculated and parameters with a direct impact on rehospitalisation necessity were also evaluated. Results: One hundred and sixty-seven hospital readmissions of 72 (54%) patients were noted at mean 22±15 months after the primary hospitalisation. Rehospitalisation index per patient for the total follow-up period was 1.26, while for the first year of follow-up it was 0.69. In the case of 42 (32%) patients, 91 (54.5%) hospital readmissions were associated with arrhythmia. In 34 (25.6%) patients, 54 (32.3%) rehospitalisations were not related to arrhythmia, while 20 (15%) patients were hospitalised 22 times (13.2%) for non-cardiac reasons. Mean time to the first readmission, regardless of the reason, was 9±9 months. Predominant causes of repeat hospitalisation were ventricular arrhythmias and worsening of heart failure. Patients with left ventricular ejection fraction (LVEF) below 30% and in functional NYHA class III were readmitted to hospital more frequently for reasons not related to arrhythmia. Conclusions: Hospital readmissions for cardiac causes in patients after ICD implantation are still frequent. Most of them are caused by ventricular arrhythmia and heart failure. Low LVEF (Wst臋p: Rehospitalizacje s膮 jednym z istotnych problem贸w u chorych ze wszczepionym kardiowerterem-defibrylatorem (implantable cardioverter defibrillator, ICD). Dok艂adna analiza przyczyn rehospitalizacji mo偶e wp艂ywa膰 na popraw臋 post臋powania u chorych z ICD i ograniczy膰 ich liczb臋. Cel: Prospektywna analiza cz臋sto艣ci, przyczyn i czasu do pierwszej rehospitalizacji chorych po implantacji kardiowertera-defibrylatora (ICD). Poszukiwano r贸wnie偶 czynnik贸w predysponuj膮cych do ich wyst膮pienia. Metodyka: Analiz膮 obj臋to 133 kolejnych chorych, kt贸rym wszczepiono ICD w Klinice Kardiologii PAM. Przyczyny rehospitalizacji podzielono na kardiologiczne i niekardiologiczne. Obliczono wsp贸艂czynnik rehospitalizacji oraz zbadano, kt贸re parametry mia艂y niezale偶ny wp艂yw na konieczno艣膰 rehospitalizacji. Wyniki: Zaobserwowano 167 ponownych hospitalizacji u 72 (54%) pacjent贸w po 艣rednio 22±15 mies. Wsp贸艂czynnik rehospitalizacji przypadaj膮cy na pacjenta podczas ca艂ego okresu obserwacji wyni贸s艂 1,26, natomiast podczas roku 0,69. U 42 (32%) pacjent贸w wyst膮pi艂o 91 (54,5%) ponownych przyj臋膰 do szpitala z powod贸w zwi膮zanych z arytmi膮. U 34 (25,6%) chorych stwierdzono 54 (32,3%) rehospitalizacji niezwi膮zanych z arytmi膮, a 20 (15%) pacjent贸w hospitalizowano z przyczyn niekardiologicznych, rejestruj膮c 22 (13,2%) takich hospitalizacji. Œredni czas do wyst膮pienia pierwszej hospitalizacji, niezale偶nie od jej przyczyny, wyni贸s艂 9±9 mies. G艂贸wnymi powodami, z kt贸rych pacjent贸w przyjmowano do szpitala, by艂y arytmie komorowe i niewydolno艣膰 serca. Ustalono, i偶 pacjenci z frakcj膮 wyrzutow膮 lewej komory (LVEF) poni偶ej 30% oraz z dolegliwo艣ciami w III klasie NYHA byli cz臋艣ciej hospitalizowani z przyczyn niezwi膮zanych z arytmi膮. Wnioski: Hospitalizacje z przyczyn kardiologicznych u pacjent贸w po implantacji ICD s膮 nadal cz臋stym zjawiskiem. Wi臋kszo艣膰 z nich jest spowodowana arytmiami komorowymi oraz niewydolno艣ci膮 serca. Niska LVEF
    corecore