1,041 research outputs found

    A Walsh-Fourier approach to the circulant Hadamard conjecture

    Get PDF
    We describe an approach to the circulant Hadamard conjecture based on Walsh-Fourier analysis. We show that the existence of a circulant Hadamard matrix of order nn is equivalent to the existence of a non-trivial solution of a certain homogenous linear system of equations. Based on this system, a possible way of proving the conjecture is proposed.Comment: 8 page

    Low noise all-fiber amplification of a coherent supercontinuum at 2 \mu m and its limits imposed by polarization noise

    Get PDF
    We report the amplification of an all-normal dispersion supercontinuum pulse in a Thulium / Holmium co-doped all-fiber chirped pulse amplification system. With a -20 dB bandwidth of more than 300 nm in the range 1800-2100 nm the system delivers high quality 66 fs pulses with more than 70 kW peak power directly from the output fiber. The coherent seeding of the entire emission bandwidth of the doped fiber and the stability of the supercontinuum generation dynamics in the silicate glass all-normal dispersion photonic crystal fiber result in excellent noise characteristics of the amplified ultrashort pulses

    Electrical resistivity change in amorphous Ta42Si13N45 films by stress relaxation

    Get PDF
    In a first experiment, a reactively sputtered amorphous Ta₄₂Si₁₃N₄₅ film about 260 nm thick deposited on a flat and smooth alumina substrate was thermally annealed in air for 30 min and let cooled again repeatedly at successively higher temperatures from 200 to 500 °C. This treatment successively and irreversibly increases the room temperature resistivity of the film monotonically from its initial value of 670 μΩ cm to a maximum of 705 μΩ cm (+5.2 %). Subsequent heat treatments at temperatures below 500 °C and up to 6 h have no further effect on the room temperature resistivity. The new value remains unchanged after 3.8 years of storage at room temperature. In a second experiment, the evolution of the initially compressive stress of a film similarly deposited by reactive sputtering on a 2-inch silicon wafer was measured by tracking the wafer curvature during similar thermal annealing cycles. A similar pattern of irreversible and reversible changes of stress was observed as for the film resistivity. Transmission electron micrographs and secondary ion mass profiles of the film taken before and after thermal annealing in air establish that both the structure and the composition of the film scarcely change during the annealing cycles. We reason that the film stress is implicated in the resistivity change. In particular, to interpret the observations, a model is proposed where the interface between the film and the substrate is mechanically unyielding

    Stability of postmortem methemoglobin: Artifactual changes caused by storage conditions.

    Get PDF
    Hemoglobin is the protein in red blood cells that carries and distributes oxygen to the body. Methemoglobinemia is a blood disorder in which an abnormal amount of methemoglobin (MetHb), a form of hemoglobin (Hb), is produced from either inadequate MetHb reductase activity or too much MetHb production or by exposure to oxidizing agents. This could lead to anoxia and death if it is not treated. However, this parameter has not been investigated as a valid post-mortem indicator because random MetHb levels have been observed in various studies: MetHb increases can be observed due to autoxidation during storage, and MetHb decreases can be observed due to MetHb reductase or microbial activity in post-mortem samples. MetHb variations can also come from the blood state and can interfere in the optical measurements of MetHb. We have studied the post-mortem MetHb concentrations according to various storage conditions. Based on our results, both the post-mortem delay and the delay before analysis should be reduced whenever possible to avoid changes in MetHb. If the analysis is delayed for a short period of time (two weeks), the blood sample taken at autopsy should not be frozen but collected in EDTA preservative and stored under refrigeration (4-6°C) until analysis. If the analysis is delayed for a longer period (more than two weeks), the blood sample should be frozen with cryoprotectant at -80°C or -196°C

    Functional imaging of mucociliary phenomena: High-speed digital reflection contrast microscopy

    Get PDF
    We present a technique for the investigation of mucociliary phenomena on trachea explants under conditions resembling those in the respiratory tract. Using an enhanced reflection contrast, we detect simultaneously the wave-like modulation of the mucus surface by the underlying ciliary activity and the transport of particles embedded in the mucus layer. Digital recordings taken at a speed of 500 frames per second are analyzed by a set of refined data processing algorithms. The simultaneously extracted data include not only ciliary beat frequency and its surface distribution, but also space-time structure of the mucociliary wave field, wave velocity and mucus transport velocity. Furthermore, we propose the analysis of the space and time evolution of the phase of the mucociliary oscillations to be the most direct way to visualize the coordination of the cilia. In particular, this analysis indicates that the synchronization is restricted to patches with varying directions of wave propagation, but the transport direction is strongly correlated with the mean direction of waves. The capabilities of the technique and of the data-processing algorithms are documented by characteristic data obtained from mammalian and avine trachea

    Anisotropic random resistor networks: a model for piezoresistive response of thick-film resistors

    Full text link
    A number of evidences suggests that thick-film resistors are close to a metal-insulator transition and that tunneling processes between metallic grains are the main source of resistance. We consider as a minimal model for description of transport properties in thick-film resistors a percolative resistor network, with conducting elements governed by tunneling. For both oriented and randomly oriented networks, we show that the piezoresistive response to an applied strain is model dependent when the system is far away from the percolation thresold, while in the critical region it acquires universal properties. In particular close to the metal-insulator transition, the piezoresistive anisotropy show a power law behavior. Within this region, there exists a simple and universal relation between the conductance and the piezoresistive anisotropy, which could be experimentally tested by common cantilever bar measurements of thick-film resistors.Comment: 7 pages, 2 eps figure

    Matrix permanent and quantum entanglement of permutation invariant states

    Full text link
    We point out that a geometric measure of quantum entanglement is related to the matrix permanent when restricted to permutation invariant states. This connection allows us to interpret the permanent as an angle between vectors. By employing a recently introduced permanent inequality by Carlen, Loss and Lieb, we can prove explicit formulas of the geometric measure for permutation invariant basis states in a simple way.Comment: 10 page
    corecore