269 research outputs found
Magnetic behaviour of non-interacting colloidal iron oxide nanoparticles in physiological solutions
Magnetic properties of colloidal nanoparticles (NPs) depend on various
parameters, such as size, size distribution, interparticle distance, shape,
condition of synthesis and stabilizing surfactants. Nowadays, those magnetic
nanoparticles (MNPs) are preferably produced in hydrophobic organic solvents,
while biomedical applications need hydrophilic properties. Thus, a major
challenge is the hydrophilization of the particles, while avoiding
destabilization and aggregation. Here we present magnetic characteristics of
non-interacting, highly crystalline iron oxide NPs in physiological solutions
that are coated with modified polyacrylic acid. The magnetic analysis
comprised both static and dynamic magnetic behaviour of 4 nm NPs. The NPs have
been further characterized by transmission electron microscopy (TEM) and
energy dispersive X-ray spectroscopy (EDX)
A Search for Scalar Chameleons with ADMX
Scalar fields with a "chameleon" property, in which the effective particle
mass is a function of its local environment, are common to many theories beyond
the standard model and could be responsible for dark energy. If these fields
couple weakly to the photon, they could be detectable through the "afterglow"
effect of photon-chameleon-photon transitions. The ADMX experiment was used in
the first chameleon search with a microwave cavity to set a new limit on scalar
chameleon-photon coupling excluding values between 2*10^9 and 5*10^14 for
effective chameleon masses between 1.9510 and 1.9525 micro-eV.Comment: 4 pages, 3 figure
A method to localize gamma-ray bursts using POLAR
The hard X-ray polarimeter POLAR aims to measure the linear polarization of
the 50-500 keV photons arriving from the prompt emission of gamma-ray bursts
(GRBs). The position in the sky of the detected GRBs is needed to determine
their level of polarization. We present here a method by which, despite of the
polarimeter incapability of taking images, GRBs can be roughly localized using
POLAR alone. For this purpose scalers are attached to the output of the 25
multi-anode photomultipliers (MAPMs) that collect the light from the POLAR
scintillator target. Each scaler measures how many GRB photons produce at least
one energy deposition above 50 keV in the corresponding MAPM. Simulations show
that the relative outputs of the 25 scalers depend on the GRB position. A
database of very strong GRBs simulated at 10201 positions has been produced.
When a GRB is detected, its location is calculated searching the minimum of the
chi2 obtained in the comparison between the measured scaler pattern and the
database. This GRB localization technique brings enough accuracy so that the
error transmitted to the 100% modulation factor is kept below 10% for GRBs with
fluence Ftot \geq 10^(-5) erg cm^(-2) . The POLAR localization capability will
be useful for those cases where no other instruments are simultaneously
observing the same field of view.Comment: 13 pages, 10 figure
A SQUID-based microwave cavity search for dark-matter axions
Axions in the micro eV mass range are a plausible cold dark matter candidate
and may be detected by their conversion into microwave photons in a resonant
cavity immersed in a static magnetic field. The first result from such an axion
search using a superconducting first-stage amplifier (SQUID) is reported. The
SQUID amplifier, replacing a conventional GaAs field-effect transistor
amplifier, successfully reached axion-photon coupling sensitivity in the band
set by present axion models and sets the stage for a definitive axion search
utilizing near quantum-limited SQUID amplifiers.Comment: 4 pages, 5 figures, submitted to PR
Move of a large but delicate apparatus on a trailer with air-ride suspension
When valuable delicate goods are shipped by truck, attention must be paid to
vibrations that may cause damage. We present a case study of moving an
extremely delicate 6230-kg superconducting magnet, immersed in liquid nitrogen,
from Livermore, CA to Seattle, WA showing the steps of fatigue analysis of the
load, a test move, and acceleration monitoring of the final move to ensure a
successful damage-free transport
Design and performance of the ADMX SQUID-based microwave receiver
The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly
interacting relic axion particles by searching for their conversion to
microwave photons in a resonant cavity positioned in a strong magnetic field.
Given the extremely low expected axion-photon conversion power we have
designed, built and operated a microwave receiver based on a Superconducting
QUantum Interference Device (SQUID). We describe the ADMX receiver in detail as
well as the analysis of narrow band microwave signals. We demonstrate the
sustained use of a SQUID amplifier operating between 812 and 860 MHz with a
noise temperature of 1 K. The receiver has a noise equivalent power of
1.1x10^-24 W/sqrt(Hz) in the band of operation for an integration time of
1.8x10^3 s.Comment: 8 pages, 12 figures, Submitted to Nuclear Inst. and Methods in
Physics Research,
Astrometric Control of the Inertiality of the Hipparcos Catalog
Based on the most complete list of the results of an individual comparison of
the proper motions for stars of various programs common to the Hipparcos
catalog, each of which is an independent realization of the inertial reference
frame with regard to stellar proper motions, we redetermined the vector
of residual rotation of the ICRS system relative to the extragalactic
reference frame. The equatorial components of this vector were found to be the
following: mas yr,
mas yr, and mas yr.Comment: 8 pages, 1 figur
Kinematics of Tycho-2 Red Giant Clump Stars
Based on the Ogorodnikov-Milne model, we analyze the proper motions of 95 633
red giant clump (RGC) stars from the Tycho-2 Catalogue. The following Oort
constants have been found: A = 15.9+-0.2 km/s/kpc and B = -12.0+-0.2 km/s/kpc.
Using 3632 RGC stars with known proper motions, radial velocities, and
photometric distances, we show that, apart from the star centroid velocity
components relative to the Sun, only the model parameters that describe the
stellar motions in the XY plane differ significantly from zero. We have studied
the contraction (a negative K-effect) of the system of RGC stars as a function
of their heliocentric distance and elevation above the Galactic plane. For a
sample of distant (500--1000 pc) RGC stars located near the Galactic plane
(|Z|<200 pc) with an average distance of d=0.7 kpc, the contraction velocity is
shown to be Kd= -3.5+-0.9 km/s; a noticeable vertex deviation, lxy = 9.1+-0.5
degrees, is also observed for them. For stars located well above the Galactic
plane (|Z|>=200 pc), these effects are less pronounced, Kd = -1.7+-0.5 km/s and
lxy = 4.9+-0.6 degrees. Using RGC stars, we have found a rotation around the
Galactic X axis directed toward the Galactic center with an angular velocity of
-2.5+-0.3 km/s/kpc, which we associate with the warp of the Galactic
stellar-gaseous disk.Comment: 23 pages, 7 figures, 4 table
Experimental evaluation of sub-sampling IQ detection for low-level RF control in particle accelerator systems
The low-level radio frequency (LLRF) control system is one of the fundamental parts of a particle accelerator, ensuring the stability of the electro-magnetic (EM) field inside the resonant cavities. It leverages on the precise measurement of the field by in-phase/quadrature (IQ) detection of an RF probe signal from the cavities, usually performed using analogue downconversion. This approach requires a local oscillator (LO) and is subject to hardware non-idealities like mixer nonlinearity and long-term temperature drifts. In this work, we experimentally evaluate IQ detection by direct sampling for the LLRF system of the Polish free electron laser (PolFEL) now under development at the National Centre for Nuclear Research (NCBJ) in Poland. We study the impact of the sampling scheme and of the clock phase noise for a 1.3-GHz input sub-sampled by a 400-MSa/s analogue-to-digital converter (ADC), estimating amplitude and phase stability below 0.01% and nearly 0.01â—¦, respectively. The results are in line with state-of-the-art implementations, and demonstrate the feasibility of direct sampling for GHz-range LLRF systems
- …