35 research outputs found
Surface electronic corrugation of a one-dimensional topological metal: Bi(114)
The surface of Bi(114) is a striking example where the reduced dimensionality gives rise to structural rearrangement and new states at the surface. Here, we present a study of the surface structure and electronic corrugation of this quasi one-dimensional topological metal based on helium atom scattering (HAS) measurements. In contrast to low-index metal surfaces, upon scattering from the stepped (114) truncation of Bi, a large proportion of the incident beam is scattered into higher order diffraction channels which in combination with the large surface unit cell makes an analysis challenging. The surface electronic corrugation of Bi(114) is determined, using measurements upon scattering normal to the steps, together with quantum mechanical scattering calculations. Therefore, minimisation routines that vary the shape of the corrugation are employed, in order to minimise the deviation between the calculations and experimental scans. Furthermore, we illustrate that quantum mechanical scattering calculations can be used to determine the orientation of the in- and outgoing beam with respect to the stepped surface structure
Origin of the Electron-Phonon Interaction of Topological Semimetal Surfaces Measured with Helium Atom Scattering
He atom scattering has been demonstrated to be a sensitive probe of the
electron-phonon interaction parameter at metal and metal-overlayer
surfaces. Here it is shown that the theory linking to the thermal
attenuation of atom scattering spectra (the Debye-Waller factor), can be
applied to topological semimetal surfaces, like the quasi-one dimensional
charge-density-wave system Bi(114) and the layered pnictogen chalcogenides
Surface properties of 1T-TaS2 and contrasting its electron-phonon coupling with TlBiTe2 from helium atom scattering
We present a detailed helium atom scattering study of the charge-density wave (CDW) system and transition metal dichalcogenide 1T-TaS2. In terms of energy dissipation, we determine the electron-phonon (e-ph) coupling, a quantity that is at the heart of conventional superconductivity and may even âdriveâ phase transitions such as CDWs. The e-ph coupling of TaS2 in the commensurate CDW phase (λ = 0.59 ± 0.12) is compared with measurements of the topo-logical insulator TlBiTe2 (λ = 0.09 ± 0.01). Furthermore, by means of elastic He diffraction and resonance/interference effects in He scattering, the thermal expansion of the surface lattice, the surface step height, and the three-dimensional atom-surface interaction potential are determined including the electronic corrugation of 1T-TaS2. The linear thermal expansion coefficient is similar to that of other transition-metal dichalcogenides. The HeâTaS2 interaction is best described by a corrugated Morse potential with a relatively large well depth and supports a large number of bound states, comparable to the surface of Bi2Se3, and the surface electronic corrugation of 1T-TaS2 is similar to the ones found for semimetal surfaces
Visual, aberrometric, photic phenomena, and patient satisfaction after myopic wavefront-guided LASIK using a high-resolution aberrometer
Sarah Moussa, Alois K Dexl, Eva M Krall, Eva M Arlt, Günther Grabner, Josef Ruckhofer Department of Ophthalmology, Paracelsus Medical University Salzburg, Salzburg, Austria Purpose: The purpose of this study was to evaluate the visual, refractive, and aberrometric outcomes as well as the level of patient satisfaction and photic phenomena after myopic laser in situ keratomileusis (LASIK) surgery using wavefront-guided (WFG) ablations based on measurements obtained with a high-resolution aberrometer. Patients and methods: This study was a prospective analysis including 253 eyes of 127 patients (aged between 19 years and 54 years) undergoing WFG LASIK using the STAR S4 IR Excimer Laser System combined with the iDesign System and iFS Femtosecond Laser. Visual, refractive, and aberrometric outcomes during a 2-month follow-up as well as patient satisfaction and photic phenomena were evaluated by means of a questionnaire. Results: A total of 85% (215/253) and 99% (251/253) of eyes achieved a postoperative (Postop) uncorrected distance visual acuity of 20/16 and 20/20, respectively, and all eyes achieved an uncorrected distance visual acuity of 20/25. Postop spherical equivalent values were within ±0.25 D and ±0.50 D in 97% and 100% of eyes, respectively. Likewise, manifest cylinder was <0.25 D in 97% (245/253) of eyes. A statistically significant reduction was found in the total root mean square (P<0.001) and in the level of primary spherical aberration (P=0.001). Postop difficulties related to vision were graded as minimal, with low levels of photic phenomena and high levels of patient satisfaction. The level of difficulty to perform daily activities and the level of glare perceived by patients while driving car were significantly decreased (P<0.001). Conclusion: WFG LASIK surgery using the technology evaluated is predictable and effective for the correction of myopia and leads to high levels of patient satisfaction. Keywords: LASIK, patient satisfaction, Wave-front guided LASIK, high resolution aberrometer, photic phenomena, glar
Correction: Benedek et al. Measuring the ElectronâPhonon Interaction in Two-Dimensional Superconductors with He-Atom Scattering. Condens. Matter 2020, 5, 79
In the original publication [1], there was a mistake in Figure 7, in that it presented erroneous energy scales. The corrected Figure 7 appears below. The authors apologize for any inconvenience caused and state that the scientific conclusions are unaffected. The original publication has also been updated