15 research outputs found

    Prospective associations between a priori dietary patterns adherence and kidney function in an elderly Mediterranean population at high cardiovascular risk.

    Get PDF
    PURPOSE: To assess the association between three different a priori dietary patterns adherence (17-item energy reduced-Mediterranean Diet (MedDiet), Trichopoulou-MedDiet and Dietary Approach to Stop Hypertension (DASH)), as well as the Protein Diet Score and kidney function decline after one year of follow-up in elderly individuals with overweight/obesity and metabolic syndrome (MetS). METHODS: We prospectively analyzed 5675 participants (55-75 years) from the PREDIMED-Plus study. At baseline and at one year, we evaluated the creatinine-based estimated glomerular filtration rate (eGFR) and food-frequency questionnaires-derived dietary scores. Associations between four categories (decrease/maintenance and tertiles of increase) of each dietary pattern and changes in eGFR (ml/min/1.73m2) or ≥ 10% eGFR decline were assessed by fitting multivariable linear or logistic regression models, as appropriate. RESULTS: Participants in the highest tertile of increase in 17-item erMedDiet Score showed higher upward changes in eGFR (β: 1.87 ml/min/1.73m2; 95% CI: 1.00-2.73) and had lower odds of ≥ 10% eGFR decline (OR: 0.62; 95% CI: 0.47-0.82) compared to individuals in the decrease/maintenance category, while Trichopoulou-MedDiet and DASH Scores were not associated with any renal outcomes. Those in the highest tertile of increase in Protein Diet Score had greater downward changes in eGFR (β: - 0.87 ml/min/1.73m2; 95% CI: - 1.73 to - 0.01) and 32% higher odds of eGFR decline (OR: 1.32; 95% CI: 1.00-1.75). CONCLUSIONS: Among elderly individuals with overweight/obesity and MetS, only higher upward change in the 17-item erMedDiet score adherence was associated with better kidney function after one year. However, increasing Protein Diet Score appeared to have an adverse impact on kidney health. TRIAL REGISTRATION NUMBER: ISRCTN89898870 (Data of registration: 2014)

    Massless geodesics in AdS5×Y(p,q)AdS_5\times Y(p,q) as a superintegrable system

    Get PDF
    A Carter like constant for the geodesic motion in the Y(p,q)Y(p,q) Einstein-Sasaki geometries is presented. This constant is functionally independent with respect to the five known constants for the geometry. Since the geometry is five dimensional and the number of independent constants of motion is at least six, the geodesic equations are superintegrable. We point out that this result applies to the configuration of massless geodesic in AdS5×Y(p,q)AdS_5\times Y(p,q) studied by Benvenuti and Kruczenski, which are matched to long BPS operators in the dual N=1 supersymmetric gauge theory.Comment: 20 pages, no figures. Small misprint is corrected in the Killing-Yano tensor. No change in any result or conclusion

    Incidence, predictors and clinical impact of permanent pacemaker insertion in women following transcatheter aortic valve implantation: Insights from a prospective multinational registry

    No full text
    To describe the incidence, predictors, and clinical impact of permanent pacemaker insertion (PPI) following transcatheter aortic valve replacement (TAVR) in women. Background: Data on pacemaker insertion complicating TAVR in women are scarce. Methods: The Women''s International Transcatheter Aortic Valve implantation (WIN-TAVI) is a prospective registry evaluating the safety and efficacy of TAVR in women. We included patients without preprocedural pacemakers and divided them into two groups: (1) PPI and (2) no-PPI. We identified PPI predictors using logistic regression and studied its clinical impact on the Valve Academic Research Consortium (VARC)-2 efficacy and safety endpoints. Results: Out of 1019 patients, 922 were included in the analysis. Post-TAVR PPI occurred in 132 (14.3%) patients. Clinical and procedural characteristics were similar in both groups. Pre-existing right bundle branch block (RBBB) was associated with a high risk of post-TAVR PPI (OR 3.62, 95% CI 1.85–7.06, p < 0.001), while implantation of balloon-expandable prosthesis was associated with a lower risk (OR 0.47, 95% CI 0.30–0.74, p < 0.001). Post-TAVR PPI prolonged in-hospital stay by a median of 2 days (11 [9–16] days in PPI vs. 9 [7–14] days in no-PPI, p = 0.005), yet risks of VARC-2 efficacy and safety endpoints at 1 year were similar in both groups (adjHR 0.95, 95% CI 0.60–1.52, p = 0.84 and adjHR 1.22, 95% CI 0.83–1.79, p = 0.31, respectively). Conclusion: Pacemaker implantation following TAVR is frequent among women and is associated with pre-existing RBBB and valve type. PPI prolongs hospital stay, albeit without any significant impact on 1-year outcomes

    Haemodynamic Issues with Transcatheter Aortic Valve Implantation

    Get PDF
    Transcatheter aortic valves are typically implanted inside the native (or failed bioprosthetic’s) leaflets, permanently forcing the old leaflets open into a pseudo-cylindrical condition. Due to the passive nature of heart valves, the dynamics of the surrounding fluid environment is critical to their optimum performance. Following intervention, the haemodynamics of the region would ideally be returned to their healthy, physiological state, but major alterations are currently inevitable, such as increased peak flow velocity, the presence of stagnation regions, and increased haemolytic fluid environments. These leaflets reduce the volume of and restrict the flow into the Valsalva’s sinuses, and minimise the development of vortices and associated flow structures, which would aid washout and valve closure. Despite these differences to the healthy condition, implantation of these devices offers much improved flow from that of a moderately stenotic valve, with reduced transvalvular systolic pressure drop, peak blood velocity, and shear stress, which normally outweighs the disadvantages highlighted above, especially for high-risk patients

    New conduction abnormalities after TAVI-frequency and causes

    No full text
    Transcatheter aortic valve implantation (TAVI) is increasingly used to treat patients with aortic stenosis who are considered to be too high-risk for surgical replacement of the aortic valve. Although the procedural risks are decreasing, the occurrence of new conduction abnormalities remains a vexing issue. Both left bundle branch block and atrioventricular dissociation can affect prognosis after TAVI. Understanding the intimate relationship between the atrioventricular conduction axis and the aortic root, in addition to elucidation of factors related specifically to the procedure, devices, and patients, might help to reduce these conduction abnormalities. The purpose of this Review is to assess, and offer insights into, the available information on the frequency of new conduction abnormalities associated with TAVI, their anatomical and procedural causes, and their clinical consequences
    corecore