931 research outputs found

    A responsitivity-based criterion for accurate calibration of FTIR spectra: theoretical development and bandwidth estimation

    Get PDF
    An analytical expression for the variance of the radiance measured by Fourier-transform infrared (FTIR) emission spectrometers exists only in the limit of low noise. Outside this limit, the variance needs to be calculated numerically. In addition, a criterion for low noise is needed to identify properly calibrated radiances and optimize the instrument bandwidth. In this work, the variance and the magnitude of a noise-dependent spectral bias are calculated as a function of the system responsivity (r) and the noise level in its estimate (? r ). The criterion ? r /

    Responsivity-based Criterion For Accurate Calibration Of Ftir Emission Spectra: Theoretical Development And Bandwidth Estimation

    Get PDF
    An analytical expression for the variance of the radiance measured by Fourier-transform infrared (FTIR) emission spectrometers exists only in the limit of low noise. Outside this limit, the variance needs to be calculated numerically. In addition, a criterion for low noise is needed to identify properly calibrated radiances and optimize the instrument bandwidth. In this work, the variance and the magnitude of a noise-dependent spectral bias are calculated as a function of the system responsivity (r) and the noise level in its estimate (sigma(r)). The criterion sigma(r)/r \u3c 0.3, applied to downwelling and upwelling FTIR emission spectra, shows that the instrument bandwidth is specified properly for one instrument but needs to be restricted for another

    Proline-Glycine-Proline (PGP) and High Mobility Group Box Protein-1 (HMGB1): Potential Mediators of Cystic Fibrosis Airway Inflammation

    Get PDF
    Cystic fibrosis (CF) is chronic lung disease characterized by an unrelenting neutrophil-predominant airway inflammatory response. This inflammation leads to extracellular matrix (ECM) remodeling and eventually to the development of bronchiectasis. While many components of the immune response in CF have been well-characterized, recent data suggests that small molecules may play an important and underappreciated role in this inflammation. This review will examine two novel molecules: proline-glycine-proline (PGP) and high mobility group box protein-1 (HMGB1), and their potential impact in CF lung disease. This review will provide a brief overview of CF lung disease and background on both HMGB1 and PGP. It will then focus on these molecules in a murine model of CF-like airway disease and in human biological specimens from CF individuals. Finally, this manuscript will address possible mechanisms for therapeutic targeting of these bioactive mediators

    Influence of early postmortem protein oxidation on beef quality

    Get PDF
    The objective of this study was to examine the effect of early postmortem protein oxidation on the color and tenderness of beef steaks. To obtain a range of oxidation levels, the longissimus lumborum muscles (LM) from both strip loins of 20 steers fed either a finishing diet with vitamin E (1,000 IU per steer daily, minimum of 126 d [VITE]; n = 10 steers) or fed the same finishing diet without vitamin E (CON; n = 10 steers) were used. Within 24 h after slaughter, the LM muscle from each carcass was cut into 2.54-cm-thick steaks and individually vacuum packaged. Steaks from each steer were assigned to a nonirradiated group or an irradiated group. Steaks were irradiated within 26 h postmortem, and were aged at 4°C for 0, 1, 3, 7, and 14 d after irradiation. Steaks from each diet/irradiation/aging time treatment were used to determine color, shear force, and degree of protein oxidation (carbonyl content). Steaks from steers fed the VITE diet had higher (P \u3c 0.01) α-tocopherol contents than steaks from steers fed the CON diet. Immediately following irradiation, steaks that had been irradiated had lower (P \u3c 0.05) L* values regardless of diet. Irradiated steaks, regardless of diet, had lower a* (P \u3c 0.05) and b* (P \u3c 0.01) values than nonirradiated steaks at all aging times. Carbonyl concentration was higher (P \u3c 0.05) in proteins from irradiated steaks compared to nonirradiated steaks at 0, 1, 3, and 7 d postirradiation. Immunoblot analysis showed that vitamin E supplementation decreased the number and extent of oxidized sarcoplasmic proteins. Protein carbonyl content was positively correlated with Warner-Bratzler shear force values. These results indicate that increased oxidation of muscle proteins early postmortem could have negative effects on fresh meat color and tenderness

    Influence of harvest processes on pork loin and ham quality

    Get PDF
    The purpose of this study was to determine the specific effects of extending the interval between dwell time and the duration of scalding on pork quality attributes. Sixty-four Duroc × Yorkshire pigs were randomly assigned to a 2 × 2 factorial treatment arrangement. Treatments included extending the dwell duration from 5 to 10 min and extending the scald duration from 5 to 8 min. All carcasses entered the cooler 50 min after exsanguination. At exsanguination, blood was collected for three 1-min intervals and then for a final 2-min period. Temperature and pH of the LM and semimembranosus muscle (SM) were measured at 45 min, and at 2, 4, 6, and 24 h postmortem (PM). Hunter L*, a*, and b* values were determined on the LM, SM, and biceps femoris (BF). Purge loss was measured on the SM, BF, and the sirloin end of the loin. Drip loss was measured in duplicate from LM chops after 1 and 5 d of storage. Warner-Bratzler shear force (WBS) measurements were determined on LM chops aged 1, 3, 5, and 7 d PM. Over 99% of the collected blood was obtained during the first 3 min after sticking. Carcasses scalded for 8 min had greater (P \u3c 0.05) semi-membranosus 2 h temperature (28.8°C) than carcasses scalded 5 min (27.3°C). An 8-min scald process resulted in longissimus dorsi chops with lower hue angle and greater WBS values than the 5-min scald process. Increasing dwell time from 5 to 10 min resulted in biceps femoris chops with greater hue angle and loin chops with greater WBS values at 3 d PM. Harvest processes did not significantly affect subjective quality scores, Hunter L* values, purge or drip loss. Lengthening the duration of dwell and scalding may result in a more rapid PM pH decline. Reducing the duration of scalding may lead to increased time for manual removal of hair. Because of differences in facilities, it is recommended that individual facilities monitor dwell and scald durations to determine how to best minimize time of entry into the cooler

    Evaluation of Temperature-Dependent Complex Refractive Indices of Supercooled Liquid Water Using Downwelling Radiance and In-Situ Cloud Measurements at South Pole

    Get PDF
    Clouds have a large effect on the radiation budget and represent a major source of uncertainty in climate models. Supercooled liquid clouds can exist at temperatures as low as 235 K, and the radiative effect of these clouds depends on the complex refractive index (CRI) of liquid water. Laboratory measurements have demonstrated that the liquid-water CRI is temperature-dependent, but corroboration with field measurements is difficult. Here we present measurements of the downwelling infrared radiance and in-situ measurements of supercooled liquid water in a cloud at temperatures as low as 240 K, made at South Pole Station in 2001. These results demonstrate that including the temperature dependence of the liquid-water CRI is essential for accurate calculations of radiative transfer through supercooled liquid clouds. Furthermore, we show that when cloud properties are retrieved from infrared radiances (using the spectral range 500–1,200 cm−1) spurious ice may be retrieved if the 300 K CRI is used for cold liquid clouds (∼240 K). These results have implications for radiative transfer in climate models as well as for retrievals of cloud properties from infrared radiance spectra.publishedVersio

    Statistics for the Evaluation and Comparison of Models

    Get PDF
    Copyright 1985 by the American Geophysical Union.Procedures that may be used to evaluate the operational performance of a wide spectrum of geophysical models are introduced. Primarily using a complementary set of difference measures, both model accuracy and precision can be meaningfully estimated, regardless of whether the model predictions are manifesteda s scalars,d irections,o r vectors.I t is additionally suggestedth at the reliability of the accuracy and precision measures can be determined from bootstrap estimates of confidence and significance. Recommendedp roceduresa re illustrated with a comparativee valuation of two models that estimate wind velocity over the South Atlantic Bight
    • …
    corecore