255 research outputs found

    Evaluation of different POCT devices for glucose measurement in a clinical neonatal setting

    Get PDF
    Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite™ XL, Ascensia™ Contour™ and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importanc

    A Real-time Impedance-Based Screening Assay for Drug-Induced Vascular Leakage

    Get PDF
    Vascular leakage is a serious side effect of therapies based on monoclonal antibodies or cytokines which may lead to life-threatening situations. With the steady increase of new drug development programs for large molecules, there is an urgent need for reliable tools to assess this potential liability of new medicines in a rapid and cost-effective manner. Using human umbilical vein endothelial cells (HUVECs) as a model for endothelium, we established an impedance-based assay measuring the integrity of the endothelial cell monolayer in real time. We could demonstrate that the HUVEC monolayer in our system was a relevant model as cells expressed major junctional proteins known to be responsible for maintaining tightness as well as receptors targeted by molecules known to induce vascular leakage in vivo. We assessed the time-dependent loss of barrier function using impedance and confirmed that signals obtained corresponded well to those from standard transwell assays. We assayed a series of reference molecules which led to the expected change of barrier integrity. A nonspecific cytotoxic effect could be excluded by using human fibroblasts as a nonresponder cell line. Finally, we could show reversibility of vascular permeability induced by histamine, IL-1β, or TNF-α by coincubation with established antagonists, further demonstrating relevance of this new model. Taken together, our results suggest that impedance in combination with HUVECs as a specific model can be applied to assess clinically relevant vascular leakage on an in vitro leve

    Atorvastatin with or without an Antibody to PCSK9 in Primary Hypercholesterolemia

    Get PDF
    Background Serum proprotein convertase subtilisin/kexin 9 (PCSK9) binds to low-density lipoprotein (LDL) receptors, increasing the degradation of LDL receptors and reducing the rate at which LDL cholesterol is removed from the circulation. REGN727/SAR236553 (designated here as SAR236553), a fully human PCSK9 monoclonal antibody, increases the recycling of LDL receptors and reduces LDL cholesterol levels. Methods We performed a phase 2, multicenter, double-blind, placebo-controlled trial involving 92 patients who had LDL cholesterol levels of 100 mg per deciliter (2.6 mmol per liter) or higher after treatment with 10 mg of atorvastatin for at least 7 weeks. Patients were randomly assigned to receive 8 weeks of treatment with 80 mg of atorvastatin daily plus SAR236553 once every 2 weeks, 10 mg of atorvastatin daily plus SAR236553 once every 2 weeks, or 80 mg of atorvastatin daily plus placebo once every 2 weeks and were followed for an additional 8 weeks after treatment. Results The least-squares mean (±SE) percent reduction from baseline in LDL cholesterol was 73.2±3.5 with 80 mg of atorvastatin plus SAR236553, as compared with 17.3±3.5 with 80 mg of atorvastatin plus placebo (P Conclusions In a randomized trial involving patients with primary hypercholesterolemia, adding SAR236553 to either 10 mg of atorvastatin or 80 mg of atorvastatin resulted in a significantly greater reduction in LDL cholesterol than that attained with 80 mg of atorvastatin alone. (Funded by Sanofi and Regeneron Pharmaceuticals; ClinicalTrials. gov number, NCT01288469.

    Microbiota-derived short chain fatty acids modulate microglia and promote Aβ plaque deposition.

    Get PDF
    Previous studies have identified a crucial role of the gut microbiome in modifying Alzheimer's disease (AD) progression. However, the mechanisms of microbiome-brain interaction in AD were so far unknown. Here, we identify microbiota-derived short chain fatty acids (SCFA) as microbial metabolites which promote Aβ deposition. Germ-free (GF) AD mice exhibit a substantially reduced Aβ plaque load and markedly reduced SCFA plasma concentrations; conversely, SCFA supplementation to GF AD mice increased the Aβ plaque load to levels of conventionally colonized (specific pathogen-free [SPF]) animals and SCFA supplementation to SPF mice even further exacerbated plaque load. This was accompanied by the pronounced alterations in microglial transcriptomic profile, including upregulation of ApoE. Despite increased microglial recruitment to Aβ plaques upon SCFA supplementation, microglia contained less intracellular Aβ. Taken together, our results demonstrate that microbiota-derived SCFA are critical mediators along the gut-brain axis which promote Aβ deposition likely via modulation of the microglial phenotype

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO
    corecore