    Updated Meta-Analysis of Randomized Trials Comparing Safety and Efficacy of Intraoperative Defibrillation Testing with No Defibrillation Testing On Implantable Cardioverter-Defibrillator Implantation

    Get PDF
    Introduction: There is an ongoing debate regarding the need to conduct intraoperative defibrillation testing (DFT) at the time of implantable cardioverter-defibrillator (ICD) implantation. To provide sufficiently strong evidence for the feasibility of omitting intraoperative DFT in clinical practice, we conducted a meta-analysis of randomized controlled trials (RCT) comparing patients with DFT and no-DFT.Methods: We systematically searched Medline (via PubMed), ClinicalTrial.gov, the Cochrane Central Register of Controlled Trials, and Embase for studies evaluating DFT vs. no-DFT on ICD implantation with regard to total mortality and arrhythmic death, efficacy of first and any appropriate shock in interrupting ventricular tachycardia (VT)/ventricular fibrillation (VF), and procedural adverse events. Effect estimates [risk ratio (RR) with 95% confidence intervals (CI)] were pooled using the random-effects model.Results: Our meta-analysis included 4 RCTs comprising 3770 patients (1896 with DFT and 1874 without DFT). Total mortality (RR = 1.00, 95% CI 0.86–1.17; P = 0.98) and arrhythmic death (RR = 1.60, 95% CI 0.46-5.59: P = 0.46) were not statistically different. Both first (RR = 0.94, 95% CI 0.89–0.98; P = 0.004) and any appropriate ICD shock (RR = 0.97, 95% CI 0.95–1.00; P = 0.02) significantly increased the rate of VT/VF interruption in the group with no-DFT in comparison with DFT. Finally, the incidence of adverse events was lower in no-DFT patients (RR = 1.23; 95% CI 1.00–1.51; P = 0.05).Conclusions: The practice of DFT (as opposed to no-DFT) did not yield benefits in mortality or the overall rate of conversion of VT/VT. Moreover, a slightly higher incidence of perioperative adverse events was observed in the DFT group

    Rate-Responsive Cardiac Pacing: Technological Solutions and Their Applications

    No full text
    Modern cardiac pacemakers are equipped with a function that allows the heart rate to adapt to the current needs of the patient in situations of increased demand related to exercise and stress ("rate-response" function). This function may be based on a variety of mechanisms, such as a built-in accelerometer responding to increased chest movement or algorithms sensing metabolic demand for oxygen, analysis of intrathoracic impedance, and analysis of the heart rhythm (Q-T interval). The latest technologies in the field of rate-response functionality relate to the use of an accelerometer in leadless endocavitary pacemakers; in these devices, the accelerometer enables mapping of the mechanical wave of the heart’s work cycle, enabling the pacemaker to correctly sense native impulses and stimulate the ventricles in synchrony with the cycles of atria and heart valves. Another modern system for synchronizing pacing rate with the patient’s real-time needs requires a closed-loop system that continuously monitors changes in the dynamics of heart contractions. This article discusses the technical details of various solutions for detecting and responding to situations related to increased oxygen demand (e.g., exercise or stress) in implantable pacemakers, and reviews the results of clinical trials regarding the use of these algorithms

    The Interplay of PR Interval and AV Pacing Delays Used for Cardiac Resynchronization Therapy in Heart Failure Patients: Association with Clinical Response in a Retrospective Analysis of a Large Observational Study

    No full text
    Background. Cardiac resynchronization therapy (CRT) is a treatment for heart failure (HF) patients with prolonged QRS and impaired left ventricular (LV) systolic function. We aim to evaluate how the baseline PR interval is associated with outcomes (all-cause death or HF hospitalizations) and LV reverse remodeling (>15% relative reduction in LV end-systolic volume). Methods. Among 2224 patients with CRT defibrillators, 1718 (77.2%) had a device programmed at out-of-the-box settings (sensed AV delay: 100 ms and paced AV delay: 130 ms). Results. In this cohort of 1718 patients (78.7% men, mean age 66 years, 71.6% in NYHA class III/IV, LVEF = 27 +/- 6%), echocardiographic assessment at 6-month follow-up showed that LV reverse remodeling was not constant as a function of the PR interval; in detail, it occurred in 56.4% of all patients but was more frequent (76.6%) in patients with a PR interval of 160 ms. In a median follow-up of 20 months, the endpoint of death or HF hospitalizations occurred in 304/1718 (17.7%) patients; in the multivariable regression analysis it was significantly less frequent when the PR interval was between 150 and 170 ms (hazard ratio = 0.79, 95% confidence interval (CI): 0.63-0.99, p = 0.046). The same PR range was associated with higher probability of CRT response (odds ratio = 2.51, 95% CI: 1.41-4.47, p = 0.002). Conclusions. In a large population of CRT patients, with fixed AV pacing delays, specific PR intervals are associated with significant benefits in terms of LV reverse remodeling and lower morbidity. These observational data suggest the importance of optimizing pacing programming as a function of the PR interval to maximize CRT response and patient outcome

    Temporary transvenous cardiac pacing: a survey on current practice

    No full text
    Temporary transvenous cardiac pacing (TTCP) is a standard procedure in current practice, despite limited coverage in consensus guidelines. However, many authors reported several complications associated with TTCP, especially development of infections of cardiac implantable electronic devices (CIED). The aim of this survey was to provide a country-wide picture of current practice regarding TTCP.BACKGROUND: Temporary transvenous cardiac pacing (TTCP) is a standard procedure in current practice, despite limited coverage in consensus guidelines. However, many authors reported several complications associated with TTCP, especially development of infections of cardiac implantable electronic devices (CIED). The aim of this survey was to provide a country-wide picture of current practice regarding TTCP. METHODS: Data were collected using an online survey that was administered to members of the Italian Association of Arrhythmology and Cardiac Pacing. RESULTS: We collected data from 102 physicians, working in 81 Italian hospitals from 17/21 regions. Our data evidenced that different strategies are adopted in case of acute bradycardia with a tendency to limit TTCP mainly to advanced atrioventricular block. However, some centers reported a greater use in elective procedures. TTCP is usually performed by electrophysiologists or interventional cardiologists and, differently from previous reports, mainly by a femoral approach and with nonfloating catheters. We found high inhomogeneity regarding prevention of infections and thromboembolic complications and in post-TTCP management, associated with different TTCP volumes and a strategy for management of acute bradyarrhythmias. CONCLUSION: This survey evidenced a high inhomogeneity in the approaches adopted by Italian cardiologists for TTCP. Further studies are needed to explore if these divergences are associated with different long-term outcomes, especially incidence of CIED-related infections

    Transvenous lead extraction procedures in women based on ESC-EHRA EORP European Lead Extraction ConTRolled ELECTRa registry: is female sex a predictor of complications

    Full text link
    AIMS Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men. METHODS AND RESULTS A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098). CONCLUSION The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females