277 research outputs found

    Outcomes of COVID-19 patients intubated after failure of non-invasive ventilation: a multicenter observational study

    Get PDF
    The efficacy of non-invasive ventilation (NIV) in acute respiratory failure secondary to SARS-CoV-2 infection remains controversial. Current literature mainly examined efficacy, safety and potential predictors of NIV failure provided out of the intensive care unit (ICU). On the contrary, the outcomes of ICU patients, intubated after NIV failure, remain to be explored. The aims of the present study are: (1) investigating in-hospital mortality in coronavirus disease 2019 (COVID-19) ICU patients receiving endotracheal intubation after NIV failure and (2) assessing whether the length of NIV application affects patient survival. This observational multicenter study included all consecutive COVID-19 adult patients, admitted into the twenty-five ICUs of the COVID-19 VENETO ICU network (February-April 2020), who underwent endotracheal intubation after NIV failure. Among the 704 patients admitted to ICU during the study period, 280 (40%) presented the inclusion criteria and were enrolled. The median age was 69 [60-76] years; 219 patients (78%) were male. In-hospital mortality was 43%. Only the length of NIV application before ICU admission (OR 2.03 (95% CI 1.06-4.98), p = 0.03) and age (OR 1.18 (95% CI 1.04-1.33), p < 0.01) were identified as independent risk factors of in-hospital mortality; whilst the length of NIV after ICU admission did not affect patient outcome. In-hospital mortality of ICU patients intubated after NIV failure was 43%. Days on NIV before ICU admission and age were assessed to be potential risk factors of greater in-hospital mortality

    In vitro evaluation of how the presence of the stent retriever and microcatheter influences aspiration parameters in thrombectomy according to their position inside the aspiration catheter

    Full text link
    BACKGROUND Several variations of the combined thrombectomy technique for acute ischemic stroke using a stent retriever and aspiration catheter have been described. The aim of our study was to assess how the presence of the microcatheter and stent retriever affect the basic aspiration parameters, namely, flow rate and aspiration force, depending on their position within the aspiration catheter. METHODS Two experimental set-ups were designed to assess changes in flow rate and aspiration force according to the position of the stent retriever and microcatheter within the aspiration catheter. RESULTS The transition of the stent retriever and microcatheter from the distal to proximal position resulted in a progressive increase in the flow rate, but with no impact on aspiration force. Additionally, the size of the stent retriever had no significant effect on flow rate changes and the reduction in flow rate was related to the microcatheter diameter. Negative pressure generated inside the aspiration catheter impacted on its distal segment located beyond the radiopaque marker, thus leading to its partial collapse. As a consequence, the measured aspiration force was lower than the theoretical aspiration force level for all tested aspiration catheters. CONCLUSIONS In our experimental model, the position of the stent retriever and microcatheter within the aspirator catheter affected the flow rate, but not the aspiration force. Negative pressure generated within the aspiration catheter appeared to determine a partial collapse of the distal segment that resulted in a less effective aspiration force than the theoretical aspiration force level

    Endovascular treatment strategies for simultaneous bilateral anterior circulation occlusions in acute ischemic stroke: A single-center experience and systematic review of the literature

    Get PDF
    BACKGROUND Bilateral and simultaneous occlusion of the anterior circulation is a rare event in patients with acute ischemic stroke. Although endovascular treatment is feasible and safe, the endovascular strategy to be used remains a subject of debate. OBJECTIVE To assess the different endovascular strategies proposed for the treatment of a bilateral, simultaneous anterior circulation occlusion following acute ischemic stroke. METHODS We present a retrospective study of the clinical and radiological records of all patients with a bilateral, simultaneous anterior circulation occlusion treated at our center between January 2019 and December 2022. Following the PRISMA guidelines, we also conducted a systematic review of the literature. RESULTS Two patients with a bilateral and simultaneous middle cerebral artery occlusion were treated at our center during the study period. A TICI score ≄2b was obtained in 4 out of 4 occlusions. Modified Rankin Scale (mRS) at 90 days was 0 and 4, respectively. The literature review retrieved reports on 22 patients. The most frequent bilateral occlusion sites were internal carotid artery-middle cerebral artery. The clinical presentation was severe in most patients. A combined thrombectomy technique proved to have the highest number of first-pass recanalization. A TICI ≄2b was obtained in 95% of patients and an mRS ≀2 was found in 31.8% of patients. CONCLUSIONS In patients with bilateral and simultaneous occlusion of the anterior circulation, endovascular treatment using a combined technique appears to be rapid and effective. The clinical evolution of this patient population strongly depends on the severity of the onset symptoms

    OXavidin for Tissue Targeting Biotinylated Therapeutics

    Get PDF
    Avidin is a glycoprotein from hen egg white that binds biotin with very high affinity. Here we describe OXavidin, a product containing aldehyde groups, obtained by ligand-assisted sugar oxidation of avidin by sodium periodate. OXavidin chemically reacts with cellular and tissue proteins through Schiff's base formation thus residing in tissues for weeks while preserving the biotin binding capacity. The long tissue residence of OXavidin as well as that of OXavidin/biotinylated agent complex occurs in normal and neoplastic tissues and immunohistochemistry shows a strong and homogenous stromal localization. Once localized in tissue/tumor, OXavidin becomes an “artificial receptor” for intravenous injected biotin allowing tumor targeting with biotinylated therapeutics like radioisotopes or toxins. Moreover, present data also suggest that OXavidin might be useful for the homing of biotinylated cells. Overall, OXavidin exhibits a remarkable potential for many different therapeutic applications

    Effectiveness of the preventive administration of vasoactive amines in counterbalancing significant patient blood pressure drops following nimodipine administration during mechanical thrombectomy procedures

    Get PDF
    BACKGROUND Focal vasospasm (FV) of the occluded vessel can occur during the endovascular treatment of acute ischemic stroke (AIS). Nimodipine is commonly used to treat vasospasm and can play a role in distinguishing it from artery narrowing due to iatrogenic dissection or residual clot. However, nimodipine administration can result in arterial hypotension and subsequent enlargement of the ischemic core. OBJECTIVE To assess the efficacy of preventive and continuous vasoactive amine infusion to counterbalance nimodipine-induced hypotension. METHODS We reviewed data from a prospective registry of patients treated for AIS between January 2019 and January 2022 who were administered nimodipine. All patients were equipped with an arterial cannula for invasive blood pressure measurement and given vasoactive amines preemptively before general anesthesia and throughout the procedure. Data obtained from invasive monitoring of mean arterial blood pressure (MABP) in a time-lapse of 25 min before and after nimodipine administration were analyzed. RESULTS MABP significantly decreased after nimodipine administration but remained within the recommended range (81.79 ± 0.49 mmHg). Nimodipine was effective in reducing FV caused by stent retriever passage in 76.3% of cases. Furthermore, it proved valuable in diagnosing iatrogenic dissection (9.2%), residual clot (10.5%), or intracranial stenosis (4%). CONCLUSIONS Infusion of vasoactive amines effectively counteracted the intraarterial nimodipine effect, thus avoiding frank arterial hypotension during endovascular treatment. Nimodipine has been useful in differentiating the diagnosis of FV resulting from mechanical thrombectomy and other potential causes, such as iatrogenic dissection or residual clot

    Static compliance and driving pressure are associated with ICU mortality in intubated COVID-19 ARDS

    Get PDF
    Background Pathophysiological features of coronavirus disease 2019-associated acute respiratory distress syndrome (COVID-19 ARDS) were indicated to be somewhat different from those described in nonCOVID-19 ARDS, because of relatively preserved compliance of the respiratory system despite marked hypoxemia. We aim ascertaining whether respiratory system static compliance (Crs), driving pressure (DP), and tidal volume normalized for ideal body weight (VT/kg IBW) at the 1st day of controlled mechanical ventilation are associated with intensive care unit (ICU) mortality in COVID-19 ARDS. Methods Observational multicenter cohort study. All consecutive COVID-19 adult patients admitted to 25 ICUs belonging to the COVID-19 VENETO ICU network (February 28th-April 28th, 2020), who received controlled mechanical ventilation, were screened. Only patients fulfilling ARDS criteria and with complete records of Crs, DP and VT/kg IBW within the 1st day of controlled mechanical ventilation were included. Crs, DP and VT/kg IBW were collected in sedated, paralyzed and supine patients. Results A total of 704 COVID-19 patients were screened and 241 enrolled. Seventy-one patients (29%) died in ICU. The logistic regression analysis showed that: (1) Crs was not linearly associated with ICU mortality (p value for nonlinearity = 0.01), with a greater risk of death for values < 48 ml/cmH(2)O; (2) the association between DP and ICU mortality was linear (p value for nonlinearity = 0.68), and increasing DP from 10 to 14 cmH(2)O caused significant higher odds of in-ICU death (OR 1.45, 95% CI 1.06-1.99); (3) VT/kg IBW was not associated with a significant increase of the risk of death (OR 0.92, 95% CI 0.55-1.52). Multivariable analysis confirmed these findings. Conclusions Crs < 48 ml/cmH(2)O was associated with ICU mortality, while DP was linearly associated with mortality. DP should be kept as low as possible, even in the case of relatively preserved Crs, irrespective of VT/kg IBW, to reduce the risk of death

    Argument mining as rapid screening tool of COVID-19 literature quality: Preliminary evidence

    Get PDF
    BackgroundThe COVID-19 pandemic prompted the scientific community to share timely evidence, also in the form of pre-printed papers, not peer reviewed yet.PurposeTo develop an artificial intelligence system for the analysis of the scientific literature by leveraging on recent developments in the field of Argument Mining.MethodologyScientific quality criteria were borrowed from two selected Cochrane systematic reviews. Four independent reviewers gave a blind evaluation on a 1–5 scale to 40 papers for each review. These scores were matched with the automatic analysis performed by an AM system named MARGOT, which detected claims and supporting evidence for the cited papers. Outcomes were evaluated with inter-rater indices (Cohen's Kappa, Krippendorff's Alpha, s* statistics).ResultsMARGOT performs differently on the two selected Cochrane reviews: the inter-rater indices show a fair-to-moderate agreement of the most relevant MARGOT metrics both with Cochrane and the skilled interval scores, with larger values for one of the two reviews.Discussion and conclusionsThe noted discrepancy could rely on a limitation of the MARGOT system that can be improved; yet, the level of agreement between human reviewers also suggests a different complexity between the two reviews in debating controversial arguments. These preliminary results encourage to expand and deepen the investigation to other topics and a larger number of highly specialized reviewers, to reduce uncertainty in the evaluation process, thus supporting the retraining of AM systems
    • 

    corecore