16 research outputs found

    AIRO Breast Cancer Group Best Clinical Practice 2022 Update

    Get PDF
    Introduction: Breast cancer is the most common tumor in women and represents the leading cause of cancer death. Radiation therapy plays a key-role in the treatment of all breast cancer stages. Therefore, the adoption of evidence-based treatments is warranted, to ensure equity of access and standardization of care in clinical practice.Method: This national document on the highest evidence-based available data was developed and endorsed by the Italian Association of Radiation and Clinical Oncology (AIRO) Breast Cancer Group.We analyzed literature data regarding breast radiation therapy, using the SIGN (Scottish Intercollegiate Guidelines Network) methodology (www.sign.ac.uk). Updated findings from the literature were examined, including the highest levels of evidence (meta-analyses, randomized trials, and international guidelines) with a significant impact on clinical practice. The document deals with the role of radiation therapy in the treatment of primary breast cancer, local relapse, and metastatic disease, with focus on diagnosis, staging, local and systemic therapies, and follow up. Information is given on indications, techniques, total doses, and fractionations.Results: An extensive literature review from 2013 to 2021 was performed. The work was organized according to a general index of different topics and most chapters included individual questions and, when possible, synoptic and summary tables. Indications for radiation therapy in breast cancer were examined and integrated with other oncological treatments. A total of 50 questions were analyzed and answered.Four large areas of interest were investigated: (1) general strategy (multidisciplinary approach, contraindications, preliminary assessments, staging and management of patients with electronic devices); (2) systemic therapy (primary, adjuvant, in metastatic setting); (3) clinical aspects (invasive, non-invasive and micro-invasive carcinoma; particular situations such as young and elderly patients, breast cancer in males and cancer during pregnancy; follow up with possible acute and late toxicities; loco-regional relapse and metastatic disease); (4) technical aspects (radiation after conservative surgery or mastectomy, indications for boost, lymph node radiotherapy and partial breast irradiation).Appendixes about tumor bed boost and breast and lymph nodes contouring were implemented, including a dedicated web application. The scientific work was reviewed and validated by an expert group of breast cancer key-opinion leaders.Conclusions: Optimal breast cancer management requires a multidisciplinary approach sharing therapeutic strategies with the other involved specialists and the patient, within a coordinated and dedicated clinical path. In recent years, the high-level quality radiation therapy has shown a significant impact on local control and survival of breast cancer patients. Therefore, it is necessary to offer and guarantee accurate treatments according to the best standards of evidence-based medicine

    Preliminary Report on the Second Season of the Italian Archeological Mission in the Eastern Desert of Egypt

    No full text
    International audienc

    Preliminary Report on the Second Season of the Italian Archeological Mission in the Eastern Desert of Egypt

    No full text
    International audienc

    Optical cavity alignment and mirror damage in the LELA FEL experiment

    No full text
    Abstract The alignment of the LELA optical cavity, 17.5 m long, is described. The procedure to attain a close alignment of the undulator radiation axis and the cavity axis using an external laser is reported. Measurements of Q from stored light spectra are presented. Mirror degradation at increasing integrated electron currents is considered

    Cone-beam computed tomography in hypofractionated stereotactic radiotherapy for brain metastases

    No full text
    Abstract Background To assess interfraction translational and rotational setup errors, in patients treated with image-guded hypofractionated stereotactic radiotherapy, immobilized by a thermoplastic mask and a bite-block and positioned using stereotactic coordinates. Methods 37 patients with 47 brain metastases were treated with hypofractionated stererotactic radiotherapy. All patients were immobilized with a combination of a thermoplastic mask and a bite-block fixed to a stereotactic frame support. Daily cone-beam CT scans were acquired for every patient before the treatment session and were matched online with planning CT images, for 3D image registration. The mean value and standard deviation of all translational (X, Y, Z) and rotational errors (θx, θy, θz) were calculated for the matching results of bone matching algorithm. Results A total of 194 CBCT scans were analyzed. Mean +/- standard deviation of translational errors (X, Y, Z) were respectively 0.5 +/- 1.6 mm (range -5.7 and 5.9 mm) in X; 0.4 +/- 2.7 mm (range -8.2 and 12.1 mm) in Y; 0.4 +/- 1.9 mm (range -7.0 and 14 mm) in Z; median and 90th percentile were respectively within 0.5 mm and 2.4 mm in X, 0.3 mm and 3.2 mm in Y, 0.3 mm and 2.2 mm in Z. Mean +/- standard deviation of rotational errors (θx, θy, θz) were respectively 0.0 degrees+/- 1.3 degrees (θx) (range -6.0 degrees and 3.1 degrees); -0.1 degrees +/- 1.1 degrees (θy) (range -3.0 degrees and 2.4 degrees); -0.6 degrees +/- 1.4 degrees (θz) (range -5.0 degrees and 3.3 degrees). Median and 90th percentile of rotational errors were respectively within 0.1 degrees and 1.4 degrees (θx), 0.0 degrees and 1.2 degrees (θy), 0.0 degrees and 0.9 degrees (θz). Mean +/- SD of 3D vector was 3.1 +/- 2.1 mm (range 0.3 and 14.9 mm); median and 90th percentile of 3D vector was within 2.7 mm and 5.1 mm. Conclusions Hypofractionated stereotactic radiotherapy have the significant limitation of uncertainty in interfraction repeatability of the patient setup; image-guided radiotherapy using cone-beam computed tomography improves the accuracy of the treatment delivery reducing set-up uncertainty, giving the possibility of 3-dimensional anatomic informations in the treatment position.</p
    corecore