30 research outputs found

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Experimental Study of the Ultrasonic Vibration-Assisted Abrasive Waterjet Micromachining the Quartz Glass

    No full text
    The ultrasonic vibration is used to enhance the capability of the abrasive water micromachining glass. And, the ultrasonic vibration is activated on the abrasive waterjet nozzle. The quality of the flow is improved, and the velocity of the abrasive is increased because of the addition of the ultrasonic energy. The relevant experimental results indicate that the erosion depth and the material volume removal of the glass are obviously increased when ultrasonic vibration is working. As for the influence of process parameters on the material removal of the glass such as vibration amplitude, system pressure, distance of the standoff, and abrasive size, the experimental results indicate that the system pressure and vibration contribute greatly to the glass material removal. Also, the erosion depth and the volume of material removal are increased with the increase in the vibration amplitude and system pressure. There are some uplifts found at the edge of erosion pit. Then, it can be inferred that the plastic method is an important material removal method during the machining process of ultrasonic vibration-assisted abrasive waterjet

    Apparatus Developments of Ultrasonic Vibration-Assisted Microabrasive Waterjet Polishing

    No full text
    The experiment apparatus of ultrasonic vibration-assisted microabrasive waterjet polishing is developed. The simulation model of ultrasonic nozzle is analyzed with the help of ANSYS software. The simulation result shows that the ultrasonic vibration leads to a good result that the maximum frequency with the value of 20908 Hz is obtained at the outlet of ultrasonic nozzle, and the vibration type is axial mode. Then the vibration frequency and amplitude of the developed experiment apparatus are tested using the ultrasonic transducer impedance analyzer and the laser displacement sensor. The measured result indicates that the vibration frequency is 19099 Hz and the amplitude is 22 μm, which means the experiment apparatus is well developed and satisfies the work requirements. The verifying experimental result shows that the ultrasonic vibration helps to enhance the machining ability of the abrasive waterjet, and the removal material volume and erosion depth are increased obviously

    Dual-/Tri-Wideband Bandpass Filter with High Selectivity and Adjustable Passband for 5G Mid-Band Mobile Communications

    No full text
    The design and implementation of the filters for the fifth-generation (5G) mobile communication systems are challengeable due to the demands of high integration, low-cost, and high-speed data transmission. In this paper, a dual-wideband bandpass filter (BPF) and a tri-wideband BPF for 5G mobile communications are proposed. The dual-wideband BPF consists of two folded open-loop stepped-impedance resonators (FOLSIRs), and the tri-wideband BPF is designed by placing a pair of folded uniform impedance resonator inside the dual-wideband BPF with little increase in the physical size of the filter. By employing a novel structural deformation of a stepped-impedance resonator, the FOLSIR is achieved with a more compact structure, a controllable transmission zero, and an adjustable resonant frequency. The measurement results show that the working bands of the two filters are 1.98&ndash;2.28/3.27&ndash;3.66 GHz and 2.035&ndash;2.305/3.31&ndash;3.71/4.54&ndash;5.18 GHz, respectively, which are consistent with the full-wave EM simulation results. The implemented filters have a compact size and the results show low loss, good out-of-band rejection, and wide passbands covering sub-6 GHz bands of 5G mobile communications and a commonly used spectrum
    corecore