    Self-occluding Candy-Plug: Implantation Technique to Obtain False Lumen Thrombosis in Chronic Aortic Dissections

    Get PDF
    Purpose: To describe the implantation steps of the latest generation of candy-plug device (third CP generation [CP III]) and to illustrate its possible pitfalls by discussing a case in whom this device was employed to occlude the false lumen (FL) of a chronic type B aortic dissection. Technique: A 69 year-old male patient who underwent a frozen elephant trunk arch repair due to residual type A aortic dissection developed a FL aneurysmal degeneration limited to the descending thoracic aorta. Two thoracic stent-grafts were deployed into the true lumen up to the celiac trunk origin. Then, the FL was occluded with a self-occluding CP III device (Cook Medical, Bloomington, Indiana), placed at the same level as the distal thoracic stent-graft. The distal un-stented sleeve was pushed upward to allow immediate occlusion of its central lumen, avoiding interference with reno-visceral arteries arising from the FL. Both intraoperative transesophageal echocardiography and follow-up computed tomographic angiography scan demonstrated complete FL thrombosis. Conclusion: The introduction of CP III with its self-occluding mechanism helped to shorten and standardize the procedure. However, adjunctive steps may be needed to immediately obtain FL occlusion and avoid hampering the perfusion of vessels arising from the FL

    Predicting risk of rupture and rupture-preventing reinterventions following endovascular abdominal aortic aneurysm repair

    Get PDF
    BackgroundClinical and imaging surveillance practices following endovascular aneurysm repair (EVAR) for intact abdominal aortic aneurysm (AAA) vary considerably and compliance with recommended lifelong surveillance is poor. The aim of this study was to develop a dynamic prognostic model to enable stratification of patients at risk of future secondary aortic rupture or the need for intervention to prevent rupture (rupture-preventing reintervention) to enable the development of personalized surveillance intervals. MethodsBaseline data and repeat measurements of postoperative aneurysm sac diameter from the EVAR-1 and EVAR-2 trials were used to develop the model, with external validation in a cohort from a single-centre vascular database. Longitudinal mixed-effects models were fitted to trajectories of sac diameter, and model-predicted sac diameter and rate of growth were used in prognostic Cox proportional hazards models. ResultsSome 785 patients from the EVAR trials were included, of whom 155 (197 per cent) experienced at least one rupture or required a rupture-preventing reintervention during follow-up. An increased risk was associated with preoperative AAA size, rate of sac growth and the number of previously detected complications. A prognostic model using predicted sac growth alone had good discrimination at 2years (C-index 068), 3years (C-index 072) and 5years (C-index 075) after operation and had excellent external validation (C-index 076-079). More than 5years after operation, growth rates above 1mm/year had a sensitivity of over 80 per cent and specificity over 50 per cent in identifying events occurring within 2years. ConclusionSecondary sac growth is an important predictor of rupture or rupture-preventing reintervention to enable the development of personalized surveillance intervals. A dynamic prognostic model has the potential to tailor surveillance by identifying a large proportion of patients who may require less intensive follow-up. Potential to tailor surveillancePeer reviewe

    Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience

    Get PDF
    Objective: To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. Methods: A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres. Results: A custom made CP was used in 155 patients (92 males, mean age 62 ± 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 – 77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 – 87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve. Conclusion: This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique

    Comparison of single- and multistage strategies during fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms

    Get PDF
    Objective: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs). Methods: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single- or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality. Results: A total of 1947 patients (65% male; mean age, 71 ± 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9±1.3% vs 79.6±1.7%) and 3 years (72.7±2.1% vs 64.2±2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach. Conclusions: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years

    Vascular malformations

    No full text

    The preservation of accessory renal arteries should be considered the treatment of choice in complex endovascular aortic repair

    No full text
    Objective: The objective of this study was to evaluate renal function and renal parenchymal length changes secondary to the coverage or preservation of accessory renal arteries (ARAs) in complex aortic repair. Methods: This was a single-center retrospective study identifying all patients undergoing fenestrated or branched endovascular aortic repair (f-b EVAR) who presented with ARAs. Two groups were created, a preserved ARA group, with incorporation of the vessel as a dedicated fenestration or branch in the endograft plan, and a non-preserved ARA group, without incorporation of them. Early >30% decline of glomerular filtration rate (GFR), kidney infarcts, and endoleaks were evaluated. Mid-term results with freedom from kidney shrinkage (defined as length decrease >10%) at follow-up, freedom from GFR decrease >30%, or need for postoperative dialysis at follow-up were also analyzed. Primary assisted patency of incorporated ARAs was calculated. Results: From 2011 through 2020, 145 patients undergoing complex aortic repair presented with an ARA. After excluding ruptured aneurysms, 33 patients had the ARA preserved with their incorporation into the stent graft (preserved ARA group), and 99 did not have preservation of them (not-preserved ARA group). There were no statistical differences in demographics or type of aneurysm. Patients in the ARA-preserved group had more ARAs (median of two per patient vs one in the non-preserved ARA group; P = .01) and bigger ARAs (median 4 vs 3 mm in the non-preserved ARA group; P = .001). Early postoperative worsening >30% of GFR (23% vs 6%; P = .03) as well as postoperative renal infarction (57% vs 6%; P = .001) and ARA-related endoleaks (20% vs 0%; P = .01) were statistically higher for the not-preserved ARA group. Mid-term kidney length showed significant shrinkage in the not-preserved ARA group compared with the ARA preserved group (9.7% vs 0%; P = .001). Freedom from >30% GFR decline at 2 years was significantly higher for the preserved ARA group (83% vs 47%; P = .01).Two-year primary assisted patency of incorporated ARA was 94%. Conclusions: Complex aortic repair incorporation of ARA is feasible, with low complications and good primary assisted patency at 2 years. It leads to less postoperative early renal dysfunction as well as higher freedom for mid-term renal disfunction and kidney shrinkage. © 2022 Society for Vascular Surger

    Branched Endovascular Aortic Repair After a Migrated EVAR Bypassing a Severely Kinked Previous Endograft

    No full text
    Purpose: To describe a novel technique to repair a juxtarenal abdominal aortic aneurysm (JAAA) after failed endovascular aortic repair (EVAR) with severely kinked anatomy. Technique: We present a patient who underwent an EVAR with a Medtronic Talent device 15 years ago and a proximal cuff extension 3 years earlier for an abdominal aortic aneurysm. Computed tomography (CT) done for a known gastritis showed a 12 cm JAAA, with a migrated endograft and a type Ia endoleak (EL). Endovascular repair was performed, accessing and navigating the aneurysmal sac outside the previous graft. The type I EL was reached and the suprarenal aorta catheterized. A 4-vessel inner-branched EVAR device was deployed in the distal thoracic aorta and their target vessels bridged through femoral access. A distal bifurcated component was deployed and both iliac limbs were extended to the native distal iliac arteries. Completion angiogram as well as early and 12-month CT showed a fully patent straight course branched EVAR with no ELs. Conclusion: Complex aortic reinterventions in the presence of previous EVAR can be performed by choosing a straighter course along and parallel to the previous endograft. Several technical aspects must be considered to successfully perform this type of reinterventions. Clinical Impact: We present a technique of a complex endovascular aortic repair in a failed EVAR with kinked anatomy, navigating through the thrombosed aneurysmal sac, outside the previously placed endograft and thus obtaining a straighter path for a new branched endograft. The novelty lies in a different approach to repair a failed EVAR with a branched graft through an uncommon access on the side of the previous endograft, avoiding repeated displacement or occlusion of the new endograft. We exemplify the feasibility of such a complex procedure and highlight important steps to perform it, whether in the abdominal or even thoracic Aorta. © The Author(s) 2022