13 research outputs found

    Gadolinium-enhanced magnetic resonance angiography for hepatomesenteric vascular evaluation: single and double doses comparison in schistosomiasis patients

    Get PDF
    OBJECTIVE: To evaluate the visibility of hepatomesenteric vascular segments by 3D gadolinium-enhanced magnetic resonance (MR) angiography and to compare the method effectiveness between two different gadolinium doses (single and double doses). MATERIALS AND METHODS: A prospective study was performed with 36 schistosomiasis patients who were submitted to 3D contrast-enhanced MR angiography. Scans were performed in a high-field equipment (1.5 T), with body coil and power injector for intravenous contrast administration. Contrast double doses (Gd-DTPA 0.2 mmol/kg) and single doses (0.1 mmol/kg) were randomly used respectively in 21 and 15 patients. Studies were interpreted by consensus between two observers who have rated the visualization degree of 25 proximal vascular segments without knowing the dose used. RESULTS: Proximal and calibrous vascular segments have presented higher visualization degree in the greatest part of the sample studied. The celiac trunk, common hepatic artery, splenic artery, proximal and medium third of superior mesenteric artery, portal vein, splenic vein and superior mesenteric vein have presented grade 2 visualization in more than 70% of the sample studied. As regards comparison between different doses, there was no significant difference (p < 0.05) in the visualization degree of several structures evaluated, between double dose and single dose groups, except for an isolate case of evaluation of right hepatic artery (p = 0.008) in which the single dose group has presented a higher frequency of grade 2 visualization with statistical significance. CONCLUSION: The visualization degree of hepatomesenteric vascular segments by 3D gadolinium-enhanced MR angiography is high, especially in the proximal and calibrous segments. The comparison between groups using single and double contrast doses has demonstrated similar results.OBJETIVO: Determinar a freqüência de visualização dos segmentos da circulação hepatomesentérica pela angiografia por ressonância magnética (angio-RM) com contraste e comparar o valor do método, utilizando-se duas diferentes dosagens de gadolínio (doses simples e dupla). MATERIAIS E MÉTODOS: Estudo prospectivo de 36 pacientes esquistossomóticos submetidos a angio-RM. Os exames foram realizados em equipamento de RM de 1,5 T, usando-se bobina de corpo e bomba injetora para a administração endovenosa do contraste. Foram utilizadas, de maneira randomizada, dose dupla do contraste paramagnético (0,2 mmol/kg de Gd-DTPA) em 21 pacientes e dose simples (0,1 mmol/kg) em outros 15 pacientes. Os exames foram interpretados por dois observadores em consenso, que classificaram o grau de visualização de 25 segmentos vasculares estabelecidos para análise, sem conhecimento da dose de gadolínio utilizada. RESULTADOS: Os segmentos vasculares proximais e de maior calibre foram as estruturas com melhor grau de visualização na maioria da amostra em estudo. O tronco celíaco, a artéria hepática comum, a artéria esplênica, a croça e terço médio da artéria mesentérica superior, a veia porta, a veia esplênica e a veia mesentérica superior apresentaram grau 2 de visualização em mais de 70% da amostra. Quanto à comparação das diferentes dosagens, não houve diferença significante (p < 0,05) no grau de visualização das diversas estruturas analisadas entre os grupos dose simples e dose dupla, com uma exceção isolada: na avaliação da artéria hepática direita (p = 0,008), o grupo dose simples apresentou maior freqüência de visualização grau 2, com valor significante. CONCLUSÃO: O grau de visualização dos segmentos vasculares hepatomesentéricos pela angio-RM com contraste é elevado, sendo maior nos segmentos proximais e de maior calibre. A comparação entre os grupos que utilizaram dose simples e dupla de contraste demonstrou resultados semelhantes.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Diagnóstico por ImagemUNIFESP, EPM, Depto. de Diagnóstico por ImagemSciEL

    Experimental evaluation of 3-dimensional kinematic behavior of the cruciate ligaments

    Get PDF
    PURPOSE: The purpose of this study was to evaluate a low-cost and easily reproducible technique for biomechanical studies in cadavers. In this kind of study, the natural effect of loading of the joint and shear forces are not taken into account. The objective is to describe the plastic deformation of the ligaments into 3-dimensional space. METHOD: For 18 intact human cadaver knees, the cruciate ligaments were divided into 3 fiber bundles, the tibial or femoral fixation points were marked, and 2 perpendicular different x-ray exposures were performed, thus obtaining radiographs of spatial projections of the bundle in 3 anatomic planes (frontal, sagittal, and transversal). From the measurements made on the x-ray films, we obtained the average distance between the 2 fixation points of the cruciate ligaments on the tibia and the femur at 4 different flexion angles. RESULTS: The distance between the fixation points of the medial and lateral fiber bundles of the cruciate ligaments did not change significantly during movement. There were, however, significant variations (P OBJETIVO: Este trabalho sugere uma técnica de baixo custo e de fácil reprodutibilidade para o estudo biomecânico em cadáveres. Neste tipo de estudo os efeitos das cargas naturais na articulação não são estudados. O objetivo é descrever a deformação plástica dos ligamentos no espaço tridimensional. MÉTODO: 18 joelhos provenientes de cadáveres humanos tiveram seus ligamentos cruzados divididos em três feixes de fibras cada e suas respectivas fixações tibiais e femorais marcadas, quando foram submetidos a duas exposições radiográficas perpendiculares para podermos obter uma projeção dos ligamentos nos três planos anatômicos (frontal, sagital e transversal). Através das medidas feitas nas radiografias nós obtivemos a média da distância entre os pontos de fixação na tíbia e no fêmur em quatro diferentes graus de flexão. RESULTADOS: Analisando os dados nós observamos que a distância entre os pontos de fixação dos feixes medial e lateral de ambos os ligamentos cruzados não alterou de forma significativa durante o movimento. Contudo, houve variação significativa (p>0.05) na distância entre os pontos de fixação do feixe posterior do ligamento cruzado anterior e do feixe anterior do ligamento cruzado posterior. CONCLUSÕES: A técnica foi eficiente ao demonstrar a deformação plástica dos ligamentos cruzados. Os resultados provenientes deste tipo de estudo podem auxiliar no planejamento de programas de reabilitação física

    Avaliação experimental do comportamento cinemático tridimensional dos ligamentos cruzados

    Get PDF
    PURPOSE: The purpose of this study was to evaluate a low-cost and easily reproducible technique for biomechanical studies in cadavers. In this kind of study, the natural effect of loading of the joint and shear forces are not taken into account. The objective is to describe the plastic deformation of the ligaments into 3-dimensional space. METHOD: For 18 intact human cadaver knees, the cruciate ligaments were divided into 3 fiber bundles, the tibial or femoral fixation points were marked, and 2 perpendicular different x-ray exposures were performed, thus obtaining radiographs of spatial projections of the bundle in 3 anatomic planes (frontal, sagittal, and transversal). From the measurements made on the x-ray films, we obtained the average distance between the 2 fixation points of the cruciate ligaments on the tibia and the femur at 4 different flexion angles. RESULTS: The distance between the fixation points of the medial and lateral fiber bundles of the cruciate ligaments did not change significantly during movement. There were, however, significant variations (P ;0.05) na distância entre os pontos de fixação do feixe posterior do ligamento cruzado anterior e do feixe anterior do ligamento cruzado posterior. CONCLUSÕES: A técnica foi eficiente ao demonstrar a deformação plástica dos ligamentos cruzados. Os resultados provenientes deste tipo de estudo podem auxiliar no planejamento de programas de reabilitação física

    Liver and spleen magnetic resonance imaging evaluation in patients with chronic Schistosoma mansoni infection

    No full text
    OBJECTIVE: To qualitatively and quantitatively evaluate the morphological changes of the liver and spleen using magnetic resonance imaging (MRI) in patients with chronic infection by Schistosoma mansoni and the reproducibility of MRI findings in the hepatosplenic evaluation of these patients. MATERIALS AND METHODS: We prospectively studied 28 schistosomotic patients submitted to MRI of the upper abdomen. The scans were performed using a high field equipment (1.5 T), a body coil and a power injector for administration of intravenous contrast. The scans were interpreted by two independent examiners who evaluated the presence of morphological changes in the liver and spleen. Interobserver and intraobserver agreement were measured using the kappa and intraclass correlation tests. RESULTS: Qualitative variables presented good interobserver and intraobserver agreement (kappa > 0.65 and r > 0.66, respectively). The best interobserver agreement was for the anteroposterior diameter of the spleen (r = 0.98). The observers identified reduction of the right hepatic lobe, enlargement of the left hepatic lobe and caudate lobes associated with splenomegaly in almost all patients, and also identified fissure widening, heterogeneity of hepatic parenchyma, irregularity of hepatic contours, presence of peripheral hepatic vessels and periportal fibrosis in almost all patients. CONCLUSION: Hepatic morphological changes are characterized by reduction of the right lobe and enlargement of the caudate and left lobes, and morphological changes in the spleen are characterized by the presence of splenomegaly and siderotic nodules. MRI presents high reproducibility for the evaluation of these changes in patients with chronic infection by Schistosoma mansoni.OBJETIVO: Avaliar, qualitativa e quantitativamente, as alterações morfológicas hepáticas e esplênicas por ressonância magnética (RM) em pacientes portadores de esquistossomose mansônica crônica, e a reprodutibilidade do método na avaliação hepatoesplênica destes pacientes. MATERIAIS E MÉTODOS: Realizou-se estudo prospectivo em 28 pacientes esquistossomóticos submetidos à RM de abdome superior. Os exames foram realizados em equipamento com alto campo (1,5 T), utilizando-se bobina de corpo e bomba injetora para a administração do contraste endovenoso, e interpretados por dois examinadores independentes, que avaliaram a presença de alterações morfológicas hepáticas e esplênicas. A concordância interobservador e intra-observador foram medidas pelo teste kappa e pelo teste do coeficiente de correlação intraclasses. RESULTADOS: As variáveis qualitativas e quantitativas apresentaram boa concordância interobservador e intra-observador (kapa > 0,65 e r > 0,66, respectivamente). A maior concordância interobservador foi obtida para o diâmetro ântero-posterior do baço (r = 0,98). Os observadores identificaram redução do lobo hepático direito, aumento do lobo hepático esquerdo e caudado associado a esplenomegalia em quase todos os pacientes, e alargamento de fissuras, heterogeneidade do parênquima hepático, irregularidade de contornos, vasos periféricos hepáticos e fibrose periportal em mais de 82% dos pacientes. CONCLUSÃO: As alterações morfológicas hepáticas caracterizam-se pela redução do lobo direito e aumento dos lobos caudado e esquerdo, e as esplênicas, pela presença de esplenomegalia e nódulos sideróticos. A RM apresenta elevada reprodutibilidade na avaliação dessas alterações em pacientes com esquistossomose mansônica crônica.Universidade Católica de BrasíliaUNIFESP-EPM Departamento de Diagnóstico por ImagemUNIFESP, EPM, Depto. de Diagnóstico por ImagemSciEL
    corecore