Absolute low-pressure calibration system
McLeod gage is used as the primary reference standard in a system used for absolute calibration of vacuum gages in the very low pressure range. The system involves steady-state flow of a gas through a cascade of differentially pumped chambers or stages connected by precisely defined orifices
Research and development program on the use of counting techniques
Reducing noise in multiplier of quadrupole mass spectrometer when operating in ion counting mod
Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer
The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range
Program to produce a flight prototype cold cathode quadrupole mass spectrometer
Construction of cold cathode quadrupole mass spectrometer as flight prototyp
Construction of a breadboard electronics system for a light weight cold cathode quadrupole mass spectrometer Final report, 11 Dec. 1967 - 10 Oct. 1968
Construction of breadboard electronic system for cold cathode quadrupole mass spectromete
A cold cathode ion source mass spectrometer employing ion counting techniques
Design and construction of mass spectrometer using cold cathode source of ions, quadrupole mass analyzer, and ion counting detector
A study of the adhesion and cohesion of metals Third quarterly progress report, 9 Sep. - 9 Dec. 1965
Adhesion and cohesion of metal
A study of the adhesion and cohesion of metals Interim summary report, 9 Mar. 1965 - 9 Mar. 1966
Metal alloy adhesion in high vacuu
Matter effects in the D0-D0bar system
We discuss the impact of matter effects in the D0-D0bar system. We show that
such effects could, in principle, be measured, but that they cannot be used to
probe the mass difference x_D or the lifetime difference y_D. This occurs
because the mixing effects and the matter effects decouple at short times. We
also comment briefly on the B systems.Comment: 6 pages, RevTe
- …