19 research outputs found

    Effect of NaHCO3 addition on the anaerobic co-digestion of fruit and vegetable waste and sewage sludge performance

    Get PDF
    Digestion of FVW residues with sewage sludge is feasible as long as the FVW to sludge ratio fed to the batch digester is not too large. The pH is the main variable determining the reactor performance and can be controlled by NaHCO3 addition.Universidad de MĂĄlaga. Campus de Excelencia Internacional AndalucĂ­a Tech

    Hydrometallurgical extraction of Li and Co from LiCoO2 particles–Experimental and Modeling

    Get PDF
    The use of lithium-ion batteries as energy storage in portable electronics and electric vehicles is increasing rapidly, which involves the consequent increase of battery waste. Hence, the development of reusing and recycling techniques is important to minimize the environmental impact of these residues and favor the circular economy goal. This paper presents experimental and modeling results for the hydrometallurgical treatment for recycling LiCoO2 cathodes from lithium-ion batteries. Previous experimental results for hydrometallurgical extraction showed that acidic leaching of LiCoO2 particles produced a non-stoichiometric extraction of lithium and cobalt. Furthermore, the maximum lithium extraction obtained experimentally seemed to be limited, reaching values of approximately 65–70%. In this paper, a physicochemical model is presented aiming to increase the understanding of the leaching process and the aforementioned limitations. The model describes the heterogeneous solid–liquid extraction mechanism and kinetics of LiCoO2 particles under a weakly reducing environment. The model presented here sets the basis for a more general theoretical framework that would describe the process under different acidic and reducing conditions. The model is validated with two sets of experiments at different conditions of acid concentration (0.1 and 2.5 M HCl) and solid to liquid ratio (5 and 50 g L−1). The COMSOL Multiphysics program was used to adjust the parameters in the kinetic model with the experimental results.This work has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie SkƂodowska-Curie grant agreement No. 778045. Paz-Garcia acknowledges financial support from the program “Proyectos I+D+i en el marco del Programa Operativo FEDER Andalucía 2014–2020”, No. UMA18-FEDERJA-279. Cerrillo-Gonzalez acknowledges the FPU grant obtained from the Spanish Ministry of Education. The University of Malaga is acknowledged for the financial support in the postdoctoral fellowship of Villen-Guzman

    Recovery of Li and Co from LiCoO2 via Hydrometallurgical–Electrodialytic Treatment

    Get PDF
    Lithium-ion batteries play an important role in our modern society as the main option to power portable electronic devices and electric vehicles. The growing demand for these batteries encourages the development of more efficient recycling processes, aiming to decrease the environmental impact of the spent batteries and recover their valuable components. In this paper, a combined hydrometallurgical-electrodialytic method is proposed for processing battery waste. In the combined technique, the amount of leaching solution is reduced as acid is generated via electrolysis. At the same time, the use of ion-exchange membranes and the possibility of electroplating allows for a selective separation of the target metals. Experiments were performed using LiCoO2, which is one of the most used cathodes in lithium-ion batteries. First, 0.1 M HCl solution was used in batch extractions to study the kinetics of LiCoO2 dissolution, reaching an extraction of 30% and 69% of cobalt and lithium, respectively. Secondly, hydrometallurgical extraction experiments were carried out in three-compartment electrodialytic cells, enhanced with cation-exchange membranes. Experiments yielded to a selective recovery in the catholyte of 62% of lithium and 33% of cobalt, 80% of the latter electrodeposited at the cathode.This work has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie SkƂodowska-Curie grant agreement No. 778045. Financial support from E3TECH Excellence Network under project CTQ2017-90659-REDT (MCIUN, Spain) is acknowledged. Paz-Garcia acknowledges the financial support from the program “Proyectos I+D+i en el marco del Programa Operativo FEDER Andalucía 2014–2020”, No. UMA18-FEDERJA-279. Villen-Guzman acknowledges the postdoctoral fellowship obtained from the University of Malaga. Cerrillo-Gonzalez acknowledges the FPU grant obtained from the Spanish Ministry of Education

    Chemical reduction of nitrate by zero-valent iron: Shrinking-Core versus Surface Kinetics Models

    Get PDF
    Zero valent iron (ZVI) is being used in permeable reactive barriers (PRB) for the removal of oxidant contaminants, from nitrate to chlorinated organics. A sound design of these barriers requires a good understanding of kinetics. Here we present a study of the kinetics of nitrate reduction under relatively low values of pH, from 2 to 4.5. We use a particle size of 0.42 mm, which is within the recommended size for PRBs (0.2 mm to 2.0 mm). In order to avoid possible mass-transfer limitations, a well-stirred reactor coupled with a fluidized bed reactor was used. The experiments were performed at constant pH values using a pH controller that allows to accurately track the amount of acid added. Since the reduction of H+ to H2 by the oxidation of ZVI will always be present for these pH values, blank experiments (without nitrate) were performed and the rate of this H+ reduction obtained. This rate of reduction was studied using three kinetic models: a regular empirical one, the Shrinking-Core Model (SCM), and the Surface Kinetics Model (SKM). The best performance was obtained from the SKM model. Therefore, this model was also used to study the results for the nitrate reduction, also with satisfactory results. In both cases, some assumptions are introduced to maintain a moderate number of fitting parameters.This research was funded by the European Union’s Horizon 2020 research and innovation program under the Marie SkƂodowska-Curie grant agreement No. 778045, by the “Proyectos I + D + i en el marco del Programa Operativo FEDER Andalucía 2014–2020, No UMA18-FEDERJA-279” and the project from the University of Malaga, No. PPIT.UMA.B5.2018/17. Villen-Guzman acknowledges the postdoctoral fellowship obtained from the University of Malaga. Cerrillo-Gonzalez acknowledges the FPU grant obtained from the Spanish Ministry of Education

    Development and Validation of Hepamet Fibrosis Scoring System-a Simple, Non-invasive Test to Identify Patients With Nonalcoholic Fatty liver Disease With Advanced Fibrosis

    Get PDF
    BACKGROUND & AIMS: Fibrosis affects prognoses for patients with nonalcoholic fatty liver disease (NAFLD). Several non-invasive scoring systems have aimed to identify patients at risk for advanced fibrosis, but inconclusive results and variations in features of patients (diabetes, obesity and older age) reduce their diagnostic accuracy. We sought to develop a scoring system based on serum markers to identify patients with NAFLD at risk for advanced fibrosis. METHODS: We collected data from 2452 patients with NAFLD at medical centers in Italy, France, Cuba, and China. We developed the Hepamet fibrosis scoring system using demographic, anthropometric, and laboratory test data, collected at time of liver biopsy, from a training cohort of patients from Spain (n=768) and validated the system using patients from Cuba (n=344), Italy (n=288), France (n=830), and China (n=232). Hepamet fibrosis score (HFS) were compared with those of previously developed fibrosis scoring systems (the NAFLD fibrosis score [NFS] and FIB-4). The diagnostic accuracy of the Hepamet fibrosis scoring system was assessed based on area under the receiver operating characteristic (AUROC) curve, sensitivity, specificity, diagnostic odds ratio, and positive and negative predictive values and likelihood ratios. RESULTS: Variables used to determine HFS were patient sex, age, homeostatic model assessment score, presence of diabetes, levels of aspartate aminotransferase, and albumin, and platelet counts; these were independently associated with advanced fibrosis. HFS discriminated between patients with and without advanced fibrosis with an AUROC curve value of 0.85 whereas NFS or FIB-4 did so with AUROC values of 0.80 (P=.0001). In the validation set, cut-off HFS of 0.12 and 0.47 identified patients with and without advanced fibrosis with 97.2% specificity, 74% sensitivity, a 92% negative predictive value, a 76.3% positive predictive value, a 13.22 positive likelihood ratio, and a 0.31 negative likelihood ratio. HFS were not affected by patient age, body mass index, hypertransaminasemia, or diabetes. The Hepamet fibrosis scoring system had the greatest net benefit in identifying patients who should undergo liver biopsy analysis and led to significant improvements in reclassification, reducing the number of patients with undetermined results to 20% from 30% for the FIB-4 and NFS systems (P<.05). CONCLUSIONS: Using clinical and laboratory data from patients with NAFLD, we developed and validated the Hepamet fibrosis scoring system, which identified patients with advanced fibrosis with greater accuracy than the FIB-4 and NFS systems. the Hepamet system provides a greater net benefit for the decision-making process to identify patients who should undergo liver biopsy analysis
    corecore