90 research outputs found

    Short term evaluation of interocclusal distance during speech after new removable prosthesis insertion

    Get PDF
    The aim of this study was to evaluate the interocclusal distance during the pronunciation of /m/ and /s/ sounds from Portuguese Language, in partially edentulous patients before and after new partial and total prosthesis installation. The subjects were divided into two groups: Experimental group, consisting of 9 patients entirely edentate in the upper maxillary arch and classified as Kennedy Class I in the lower arch; and Control group, consisting of 9 totally dentate patients. The subjects from the first group had their worn out dentures changed and the occlusal vertical dimension (OVD) corrected. A magnetic method of jaw tracking was used to measure the interocclusal distance (mm) during pronunciation of those phonemes. Comparison between groups, by t test, showed significant difference (pO objetivo deste estudo foi avaliar a distância interoclusal durante a pronúncia dos fonemas /m/ e /s/ da Língua Portuguesa em pacientes parcialmente desdentados antes e após a instalação de novas próteses parciais inferiores e totais superiores. Os voluntários foram divididos em dois grupos: Grupo Experimental: composto por 9 pacientes totalmente desdentados na arcada dentária superior, e classificados como classe I de Kennedy na arcada dentária inferior; e Grupo Controle, composto por 9 pacientes totalmente dentados. Os voluntários do primeiro grupo tiveram suas próteses antigas substituídas e a dimensão vertical de oclusão (DVO) corrigida. O método eletromagnético do traçado dos movimentos mandibulares foi utilizado para mensurar a distância interoclusal (mm) durante a pronúncia dos referidos fonemas. A comparação dos resultados entre os grupos (teste "t") demonstrou diferença significante (

    Influência da solução de armazenagem na desmineralização do esmalte submetido à ciclagem de pH

    Get PDF
    Extracted human teeth are frequently used for research or educational purposes. Therefore, it is necessary to store them in disinfectant solutions that do not alter dental structures. Thus, this study evaluated the influence of storage solution on enamel demineralization. For that purpose, sixty samples were divided into the following groups: enamel stored in formaldehyde (F1), stored in thymol (T1), stored in formaldehyde and submitted to pH cycling (F2), stored in thymol and submitted to pH cycling (T2). All samples were evaluated by cross-sectional microhardness analysis and had their percentage of mineral volume versus micrometer (integrated area) determined. Differences between groups were found up to 30-µm depth from the enamel surface (p < 0.05), where samples from group T2 were more demineralized. It was concluded that the storage solution influenced the reaction of a dental substrate to a cariogenic challenge, suggesting that formaldehyde may increase enamel resistance to demineralization, when compared to demineralization occurring in enamel stored in thymol solution.Dentes humanos extraídos são freqüentemente utilizados para propósitos educacionais ou de pesquisa. Desta forma, é necessário o armazenamento dos mesmos em soluções desinfetantes que não alterem a estrutura dental. Para tanto, sessenta espécimes foram divididos nos seguintes grupos: esmalte armazenado em formol (F1), armazenado em timol (T1), armazenado em formol e submetido à ciclagem de pH (F2) e armazenado em timol e submetido à ciclagem de pH (T2), sendo avaliados por meio de análise de microdureza longitudinal e tiveram a porcentagem de volume mineral pro micrômetro determinada. Diferenças entre os grupos foram encontradas até a profundidade de 30µm da superfície do esmalte (

    Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins

    Get PDF
    Although visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the roughness and Knoop hardness of a visible light-polymerized acrylic resin and to compare these values to those of water-bath- and microwave-polymerized resins, in the presence of a metal framework. Thirty-six specimens measuring 30.0 x 4.0 &plusmn; 0.5 mm of a microwave- (Onda Cryl), a visible light- (Triad) and a water-bath-polymerized (Clássico) (control) acrylic resins containing a cobalt-chromium metal bar were prepared. After processing, specimens were ground with 360 to 1000-grit abrasive papers in a polishing machine, followed by polishing with cloths and 1-µm diamond particle suspension. Roughness was evaluated using a profilometer (Surfcorder SE 1700) and Knoop hardness (Kg/mm²) was assayed using a microhardness tester (Shimadzu HMV 2000) at distances of 50, 100, 200, 400 and 800 µm from the metal bar. Roughness and Knoop hardness means were submitted to two-way ANOVA and compared by Tukey and Kruskal Wallis tests at a 5% significance level Statistically significant differences were found (p;0.05). Within the limitations of this in vitro study, it was concluded that the presence of metal did not influence roughness and hardness values of any of the tested acrylic resins.Resinas acrílicas polimerizadas por luz visível têm sido indicadas para a confecção de próteses parciais removíveis. Entretanto, não há estudos determinando se a presença de estrutura metálica interfere ou não na polimerização, considerando que essa estrutura pode refletir a luz e afetar propriedades como rugosidade e dureza e, consequentemente, facilitar o acúmulo de biofilme bacteriano. O objetivo deste trabalho foi comparar os valores de rugosidade e dureza Knoop de uma resina polimerizada por luz visível com resinas acrílicas polimerizadas por microondas ou banho de água, na presença de estrutura metálica. Para tanto, trinta e seis espécimes nas dimensões de 30,0 x 4,0 &plusmn; 0,05 mm de resina acrílica polimerizada por microondas (Onda Cryl), luz visível (Triad) e banho de água (Clássico) (controle), contendo barra metálica de cobalto cromo foram preparadas. Após a polimerização, os espécimes foram acabados e polidos com lixas abrasivas de 360 a 1000 de granulação em politriz, seguidas de pasta de diamante e disco de feltro. A rugosidade foi avaliada em perfilômetro mecânico (Surfcorder SE 1700) e a dureza Knoop (Kg/mm²) em microdurômetro (Shimadzu HMV 2000) a 50, 100, 200, 400 e 800 µm de distância da barra metálica. Os valores de rugosidade e dureza Knoop foram submetidos a ANOVA a dois critérios e comparadas com os testes Tukey e Kruskal Wallis ao nível de significância de 5%. Diferenças estatisticamente significantes foram encontradas (p;0.05). Dentro das limitações deste estudo in vitro, concluiu-se que a presença de metal não influenciou nos valores de rugosidade e dureza das resinas

    Relationship among malocclusion, number of occlusal pairs and mastication

    Get PDF
    This study evaluated the relationship among malocclusion, number of occlusal pairs, masticatory performance, masticatory time and masticatory ability in completely dentate subjects. Eighty healthy subjects (mean age = 19.40 ± 4.14 years) were grouped according to malocclusion diagnosis (n = 16): Class I, Class Class II-2, Class III and Normocclusion (control). Number of occlusal pairs was determined clinically. Masticatory performance was evaluated by the sieving method, and the time used for the comminute test food was registered as the masticatory time. Masticatory ability was measured by a dichotomic self-perception questionnaire. Statistical analysis was done by one-way ANOVA, ANOVA on ranks, Chi-Square and Spearman tests. Class II-1 and III malocclusion groups presented a smaller number of occlusal pairs than Normocclusion (p < 0.0001), Class I (p < 0.001) and II-2 (p < 0.0001) malocclusion groups. Class I, and III malocclusion groups showed lower masticatory performance values compared to Normocclusion (p < 0.05) and Class II-2 (p < 0.05) malocclusion groups. There were no differences in masticatory time (p = 0.156) and ability (&#967;2 = 3.58/p= 0.465) among groups. Occlusal pairs were associated with malocclusion (rho = 0.444/p < 0.0001) and masticatory performance (rho = 0.393/p < 0.0001), but malocclusion was not correlated with masticatory performance (rho = 0.116/p= 0.306). In conclusion, masticatory performance and ability were not related to malocclusion, and subjects with Class I, II-1 and III malocclusions presented lower masticatory performance because of their smaller number of occlusal pairs

    Estilos de liderança e compatibilidade entre treinadores e jovens atletas de futebol

    Get PDF
    It is important to analyze whether the way soccer players perceive the leadership of their coaches is related to the compatibility they assume about coaches. Studies on Brazilian soccer about this topic are still few in number. Thus, this study has three objectives: (a) analyze whether the compatibility between coaches and players differs depending on the coaches' leadership styles; (b) analyze whether the compatibility between coach and players differs depending on the closer approximation between the current and preferred behaviors of coaches perceived by players, and (c) analyze if players’ perception about the leadership styles of the coaches changes according to the age of the players. The evaluation protocol included the Multidimensional Scale of Leadership in Sport and the Coach-Athlete Compatibility Measure. One hundred and eighteen young players from five elite Brazilian football clubs participated in the study. Players who evaluated more positively the leadership styles of their coaches assumed higher compatibility with the coaches, and this result did not change according to the players’ age. In conclusion, the way players perceive their coaches' leadership is related to their compatibility with the coaches, being necessary to improve coaches’ leadership styles.É importante analisar se a forma como os jogadores de futebol percebem a liderança dos seus treinadores está relacionada com a compatibilidade que assumem relativamente aos treinadores. Os estudos sobre este tema no futebol brasileiro ainda são incipientes. Assim, este estudo tem três objetivos: (a) analisar se a compatibilidade entre treinador e jogadores difere em função dos estilos de liderança dos treinadores; (b) analisar se a compatibilidade entre treinador e jogadores difere em função dos atletas perceberem maior aproximação entre os comportamentos atuais e preferidos dos treinadores e (c) analisar se a perceção dos jogadores sobre os estilos de liderança dos treinadores muda de acordo com a idade dos jogadores. O protocolo de avaliação incluiu a Escala Multidimensional de Liderança no Desporto e a Medida de Compatibilidade Treinador-Atleta. Participaram no estudo jogadores de cinco clubes da elite do futebol brasileiro. Os atletas que avaliaram mais positivamente os estilos de liderança dos treinadores assumiram maior compatibilidade relativamente aos treinadores, sendo que este resultado não variou em função da idade dos atletas. Em conclusão, a forma como os jogadores percebem a liderança dos seus treinadores está relacionada com a compatibilidade com os treinadores, sendo importante melhorar os estilos de liderança dos treinadores

    ESTIMATIVA DO POTENCIAL DE GERAÇÃO DE ENERGIA ELÉTRICA A PARTIR DA VINHAÇA

    Get PDF
    A vinhaça hoje é um dos principais resíduos em capacidade de poluição nas indústrias sucroalcooleiras, pois seu volume se mostra o principal empecilho para tratamento. Para cada litro de álcool produzido pela destilaria são gerados 10 a 14 litros de vinhaça. O aproveitamento da vinhaça para a produção de biogás aparece como uma alternativa que pode se tornar viável do ponto de vista econômico e ambiental devido a três pontos: tratamento do resíduo, produção de biogás para a geração de eletricidade e ainda a sobra do fertilizante tratado para aplicação nas lavouras. O objetivo principal deste trabalho foi estimar o potencial histórico de energia elétrica a partir da queima do biogás no processo de biodigestão anaeróbica da vinhaça de uma usina no Noroeste do estado do Paraná considerando um reator anaeróbico. Foi realizado um estudo de caso da produção de álcool da usina nas safras de 2004 a 2010. O estudo realizado neste trabalho mostra que até então a vinhaça serve apenas como biofertilizante na empresa, más possui um grande potencial energético e pode ser transformada em energia elétrica e ajudar a suprir a demanda energética da empresa

    Linear dimensional change of denture base resins cured by microwave activation

    Get PDF
    This study examined the influence of three polymerization cycles (1: heat cure - long cycle; 2: heat cure - short cycle; and 3: microwave activation) on the linear dimensions of three denture base resins, immediately after deflasking, and 30 days after storage in distilled water at 37± 2ºC. The acrylic resins used were: Clássico, Lucitone 550 and Acron MC. The first two resins were submitted to all three polymerization cycles, and the Acron MC resin was cured by microwave activation only. The samples had three marks, and dimensions of 65 mm in length, 10 mm in width and 3 mm in thickness. Twenty-one test specimens were fabricated for each combination of resin and cure cycle, and they were submitted to three linear dimensional evaluations for two positions (A and B). The changes were evaluated using a microscope. The results indicated that all acrylic resins, regardless of the cure cycle, showed increased linear dimension after 30 days of storage in water. The composition of the acrylic resin affected the results more than the cure cycles, and the conventional acrylic resin (Lucitone 550 and Clássico) cured by microwave activation presented similar results when compared with the resin specific for microwave activation.A proposta deste estudo foi comparar as alterações dimensionais de 3 resinas submetidas à polimerização com os seguintes ciclos: 1) banho d&#146;água em 73ºC durante 12 horas - ciclo longo, 2) banho d&#146;água durante 3 horas - ciclo curto, 3) energia de microondas por 3 minutos a potência de 500 W, após armazenamento em água destilada a 37 ± 2ºC durante 30 dias. As resinas usadas foram Clássico, Lucitone 550 e Acron MC. As resinas Clássico e Lucitone 550 foram submetidas aos três ciclos, enquanto a resina Acron-MC somente ao ciclo 3. Amostras medindo 65,0 x 10,0 x 3,0 mm e com marcas iguais em três pontos eqüidistantes foram confeccionadas a partir da inclusão de matrizes de aço em gesso-pedra tipo III. Foram confeccionados 21 corpos-de-prova para cada combinação resina/ciclo de polimerização e que foram submetidos a 3 leituras para cada posição (A e B), com o auxílio do microscópio de mensuração (precisão de 0,001 mm), imediatamente após a polimerização e depois do período de imersão em água por 30 dias. Os resultados mostraram que todas as resinas, independendo do ciclo a que tenham sido submetidas e das medidas avaliadas, apresentaram expansão dimensional após terem sido mantidas em água; a composição da resina interferiu na expansão dimensional mais do que o ciclo de polimerização ao qual as resinas foram submetidas; a resina convencional, quando polimerizada com energia de microondas, apresentou alteração dimensional semelhante à resina desenvolvida para a polimerização em microondas.27828

    Alteração dimensional linear de resinas para bases de próteses polimerizadas com microondas

    Get PDF
    This study examined the influence of three polymerization cycles (1: heat cure - long cycle; 2: heat cure - short cycle; and 3: microwave activation) on the linear dimensions of three denture base resins, immediately after deflasking, and 30 days after storage in distilled water at 37± 2ºC. The acrylic resins used were: Clássico, Lucitone 550 and Acron MC. The first two resins were submitted to all three polymerization cycles, and the Acron MC resin was cured by microwave activation only. The samples had three marks, and dimensions of 65 mm in length, 10 mm in width and 3 mm in thickness. Twenty-one test specimens were fabricated for each combination of resin and cure cycle, and they were submitted to three linear dimensional evaluations for two positions (A and B). The changes were evaluated using a microscope. The results indicated that all acrylic resins, regardless of the cure cycle, showed increased linear dimension after 30 days of storage in water. The composition of the acrylic resin affected the results more than the cure cycles, and the conventional acrylic resin (Lucitone 550 and Clássico) cured by microwave activation presented similar results when compared with the resin specific for microwave activation.A proposta deste estudo foi comparar as alterações dimensionais de 3 resinas submetidas à polimerização com os seguintes ciclos: 1) banho d&#146;água em 73ºC durante 12 horas - ciclo longo, 2) banho d&#146;água durante 3 horas - ciclo curto, 3) energia de microondas por 3 minutos a potência de 500 W, após armazenamento em água destilada a 37 ± 2ºC durante 30 dias. As resinas usadas foram Clássico, Lucitone 550 e Acron MC. As resinas Clássico e Lucitone 550 foram submetidas aos três ciclos, enquanto a resina Acron-MC somente ao ciclo 3. Amostras medindo 65,0 x 10,0 x 3,0 mm e com marcas iguais em três pontos eqüidistantes foram confeccionadas a partir da inclusão de matrizes de aço em gesso-pedra tipo III. Foram confeccionados 21 corpos-de-prova para cada combinação resina/ciclo de polimerização e que foram submetidos a 3 leituras para cada posição (A e B), com o auxílio do microscópio de mensuração (precisão de 0,001 mm), imediatamente após a polimerização e depois do período de imersão em água por 30 dias. Os resultados mostraram que todas as resinas, independendo do ciclo a que tenham sido submetidas e das medidas avaliadas, apresentaram expansão dimensional após terem sido mantidas em água; a composição da resina interferiu na expansão dimensional mais do que o ciclo de polimerização ao qual as resinas foram submetidas; a resina convencional, quando polimerizada com energia de microondas, apresentou alteração dimensional semelhante à resina desenvolvida para a polimerização em microondas
    corecore