385 research outputs found

    Neuraxial modulation for treatment of VT storm.

    Get PDF
    In the hyperadrenergic state of VT storm where shocks are psychologically and physiologically traumatizing, suppression of sympathetic outflow from the organ level of the heart up to higher braincenters plays a significant role in reducing the propensity for VT recurrence. The autonomic nervous system continuously receives input from the heart (afferent signaling), integrates them, and sends efferent signals to modify or maintain cardiac function and arrhythmogenesis. Spinal anesthesia with thoracic epidural infusion of bupivicaine and surgical removal of the sympathetic chain including the stellate ganglion has been shown to decrease recurrences of VT. Excess sympathetic outflow with catecholamine release can be modified with catheter-based renal denervation. The insights provided from animal experiments and in patients that are refractory to conventional therapy have significantly improved our working understanding of the heart as an end organ in the autonomic nervous system

    High speed synchrotron X-ray imaging studies of the ultrasound shockwave and enhanced flow during metal solidification processes

    Get PDF
    The highly dynamic behaviour of ultrasonic bubble implosion in liquid metal, the multiphase liquid metal flow containing bubbles and particles, and the interaction between ultrasonic waves and semisolid phases during solidification of metal were studied in situ using the complementary ultrafast and high speed synchrotron X-ray imaging facilities housed respectively at the Advanced Photon Source, Argonne National Laboratory, US, and Diamond Light Source, UK. Real-time ultrafast X-ray imaging of 135,780 frames per second (fps) revealed that ultrasonic bubble implosion in a liquid Bi-8 wt. %Zn alloy can occur in a single wave period (30 kHz), and the effective region affected by the shockwave at implosion was 3.5 times the original bubble diameter. Furthermore, ultrasound bubbles in liquid metal move faster than the primary particles, and the velocity of bubbles is 70 ~ 100% higher than that of the primary particles present in the same locations close to the sonotrode. Ultrasound waves can very effectively create a strong swirling flow in a semisolid melt in less than one second. The energetic flow can detach solid particles from the liquid-solid interface and redistribute them back into the bulk liquid very effectively

    On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of His-SYNC

    Get PDF
    Background The His-SYNC pilot trial was the first randomized comparison between His bundle pacing in lieu of a left ventricular lead for cardiac resynchronization therapy (His-CRT) and biventricular pacing (BiV-CRT), but was limited by high rates of crossover. Objective To evaluate the results of the His-SYNC pilot trial utilizing treatment-received (TR) and per-protocol (PP) analyses. Methods The His-SYNC pilot was a multicenter, prospective, single-blinded, randomized, controlled trial comparing His-CRT vs BiV-CRT in patients meeting standard indications for CRT (eg, NYHA II–IV patients with QRS >120 ms). Crossovers were required based on prespecified criteria. The primary endpoints analyzed included improvement in QRS duration, left ventricular ejection fraction (LVEF), and freedom from cardiovascular (CV) hospitalization and mortality. Results Among 41 patients enrolled (aged 64 ± 13 years, 38% female, LVEF 28%, QRS 168 ± 18 ms), 21 were randomized to His-CRT and 20 to BiV-CRT. Crossover occurred in 48% of His-CRT and 26% of BiV-CRT. The most common reason for crossover from His-CRT was inability to correct QRS owing to nonspecific intraventricular conduction delay (n = 5). Patients treated with His-CRT demonstrated greater QRS narrowing compared to BiV (125 ± 22 ms vs 164 ± 25 ms [TR], P < .001;124 ± 19 ms vs 162 ± 24 ms [PP], P < .001). A trend toward higher echocardiographic response was also observed (80 vs 57% [TR], P = .14; 91% vs 54% [PP], P = .078). No significant differences in CV hospitalization or mortality were observed. Conclusions Patients receiving His-CRT on-treatment demonstrated superior electrical resynchronization and a trend toward higher echocardiographic response than BiV-CRT. Larger prospective studies may be justifiable with refinements in patient selection and implantation techniques to minimize crossovers
    corecore