2,425 research outputs found

    Charging Ultra-nanoporous Electrodes with Size-asymmetric Ions Assisted by Apolar Solvent

    Get PDF
    We develop a statistical theory of charging quasi single-file pores with cations and anions of different sizes as well as solvent molecules or voids. This is done by mapping the charging onto a one-dimensional Blume–Emery–Griffith model with variable coupling constants. The results are supported by three-dimensional Monte Carlo simulations in which many limitations of the theory are lifted. We explore the different ways of enhancing the energy storage which depend on the competitive adsorption of ions and solvent molecules into pores, the degree of ionophilicity and the voltage regimes accessed. We identify new solvent-related charging mechanisms and show that the solvent can play the role of an “ionophobic agent”, effectively controlling the pore ionophobicity. In addition, we demonstrate that the ion-size asymmetry can significantly enhance the energy stored in a nanopore

    Nonlinear magneto-optical rotation in optically thick media

    Full text link
    Nonlinear magneto-optical rotation is a sensitive technique for measuring magnetic fields. Here, the shot-noise-limited magnetometric sensitivity is analyzed for the case of optically-thick media and high light power, which has been the subject of recent experimental and theoretical investigations.Comment: 7 pages, 4 figure

    Influence of magnetic-field inhomogeneity on nonlinear magneto-optical resonances

    Get PDF
    In this work, a sensitivity of the rate of relaxation of ground-state atomic coherences to magnetic-field inhomogeneities is studied. Such coherences give rise to many interesting phenomena in light-atom interactions, and their lifetimes are a limiting factor for achieving better sensitivity, resolution or contrast in many applications. For atoms contained in a vapor cell, some of the coherence-relaxation mechanisms are related to magnetic-field inhomogeneities. We present a simple model describing relaxation due to such inhomogeneities in a buffer-gas-free anti-relaxation coated cell. A relation is given between relaxation rate and magnetic-field inhomogeneities including the dependence on cell size and atomic spices. Experimental results, which confirm predictions of the model, are presented. Different regimes, in which the relaxation rate is equally sensitive to the gradients in any direction and in which it is insensitive to gradients transverse to the bias magnetic field, are predicted and demonstrated experimentally.Comment: 6 pages, 4 figures, Submitted to Phys. Rev.

    Cancellation of nonlinear Zeeman shifts with light shifts

    Full text link
    Nonlinear Zeeman (NLZ) shifts arising from magnetic-field mixing of the two hyperfine ground-states in alkali atoms lead to splitting of magnetic-resonance lines. This is a major source of sensitivity degradation and the so-called "heading errors" of alkali-vapor atomic magnetometers operating in the geophysical field range (B approx. 0.2-0.7 G). Here, it is shown theoretically and experimentally that NLZ shifts can be effectively canceled by light shifts caused by a laser field of appropriate intensity, polarization and frequency, a technique that can be readily applied in practical situations.Comment: 5 pages, 5 figures, to be published in PR

    AC Stark shift noise in QND measurement arising from quantum fluctuations of light polarization

    Full text link
    In a recent letter [Auzinsh {\it{et. al.}} (physics/0403097)] we have analyzed the noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of NN atomic spins by detecting optical rotation of far-detuned probe light. Here we consider maximally squeezed probe light, and carry out a detailed derivation of the contribution to the noise in a magnetometric measurement due to the differential AC Stark shift between Zeeman sublevels arising from quantum fluctuations of the probe polarization.Comment: This is a companion note to physics/040309

    Artificial Intelligence

    Get PDF
    Contains a report on a research project.M.I.T. Research Laboratory of ElectronicsM.I.T. Computation Cente

    Can a quantum nondemolition measurement improve the sensitivity of an atomic magnetometer?

    Full text link
    Noise properties of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement are considered. Such a magnetometer measures spin precession of NN atomic spins by detecting optical rotation of far-detuned light. Fundamental noise sources include the quantum projection noise and the photon shot-noise. For measurement times much shorter than the spin-relaxation time observed in the absence of light (τrel\tau_{\rm rel}) divided by N\sqrt{N}, the optimal sensitivity of the magnetometer scales as N3/4N^{-3/4}, so an advantage over the usual sensitivity scaling as N1/2N^{-1/2} can be achieved. However, at longer measurement times, the optimized sensitivity scales as N1/2N^{-1/2}, as for a usual shot-noise limited magnetometer. If strongly squeezed probe light is used, the Heisenberg uncertainty limit may, in principle, be reached for very short measurement times. However, if the measurement time exceeds τrel/N\tau_{\rm rel}/N, the N1/2N^{-1/2} scaling is again restored.Comment: Some details of calculations can be found in a companion note: physics/040712

    Direct and indirect effects of attention and visual function on gait impairment in Parkinson’s disease: influence of task and turning

    Get PDF
    Gait impairment is a core feature of Parkinson’s disease (PD) which has been linked to cognitive and visual deficits, but interactions between these features are poorly understood. Monitoring saccades allows investigation of real-time cognitive and visual processes and their impact on gait when walking. This study explored; 1) saccade frequency when walking under different attentional manipulations of turning and dual-task; and 2) direct and indirect relationships between saccades, gait impairment, vision and attention. Saccade frequency (number of fast eye-movements per-second) was measured during gait in 60 PD and 40 age-matched control participants using a mobile eye-tracker. Saccade frequency was significantly reduced in PD compared to controls during all conditions. However, saccade frequency increased with a turn and decreased under dual-task for both groups. Poorer attention directly related to saccade frequency, visual function and gait impairment in PD, but not controls. Saccade frequency did not directly relate to gait in PD, but did in controls. Instead, saccade frequency and visual function deficit indirectly impacted gait impairment in PD, which was underpinned by their relationship with attention. In conclusion, our results suggest a vital role for attention with direct and indirect influences on gait impairment in PD. Attention directly impacted saccade frequency, visual function and gait impairment in PD, with connotations for falls. It also underpinned indirect impact of visual and saccadic impairment on gait. Attention therefore represents a key therapeutic target that should be considered in future research

    Detection of radio frequency magnetic fields using nonlinear magneto-optical rotation

    Get PDF
    We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. We demonstrate a sensitivity of 100pG/Hz(RMS)100\thinspace{\rm pG/\sqrt{Hz}\thinspace(RMS)} in a 3.5 cm diameter, paraffin coated cell. Based on detection at the photon shot-noise limit, we project a sensitivity of 20pG/Hz(RMS)20\thinspace{\rm pG/\sqrt{Hz}\thinspace(RMS)}.Comment: 6 pages, 6 figure