375 research outputs found

    Food proteins and peptides

    Get PDF
    The qualitative and quantitative determination of proteins and peptides in raw or processed food is experiencing a growing interest and importance from both scientific and economic point of view. Proteomics and peptidomics are relatively new entries in the field of food security, safety and authenticity, and themselves can contribute to the emergence of new branches of the science of food, such as foodomics and the just born nutriomics, digestomics, and gut metagenomics/metaproteomics. Mass spectrometry, in combination with a wide variety of separation methods and bioinformatic tools, is the principal methodology for proteomics. Both the so-called "in-gel" and "gel-free shotgun" bottom-up approaches are widely used.Among the arguments described in this chapter there are: stress effects on gene expression, postharvest (plant) and postmortem (livestock) protein modification, food safety, quality and authentication, food processing and quality control, frauds discovery, food peptidomics and digestomics. © 2015 Elsevier B.V

    Development of a rapid LC-MS/MS Method for the determination of emerging fusarium mycotoxins enniatins and beauvericin in human biological fluids

    Get PDF
    A novel method for the simultaneous determination of enniatins A, A1, B and B1 and beauvericin, both in human urine and plasma samples, was developed and validated. The method consisted of a simple and easy pretreatment, specific for each matrix, followed by solid phase extraction (SPE) and detection by high performance liquid chromatography-tandem mass spectrometry with an electrospray ion source. The optimized SPE method was performed on graphitized carbon black cartridges after suitable dilution of the extracts, which allowed high mycotoxin absolute recoveries (76%-103%) and the removal of the major interferences from the matrix. The method was extensively evaluated for plasma and urine samples separately, providing satisfactory results in terms of linearity (R² of 0.991-0.999), process efficiency (>81%), trueness (recoveries between 85% and 120%), intra-day precision (relative standard deviation, RSD < 18%), inter-day precision (RSD < 21%) and method quantification limits (ranging between 20 ng·L(-)¹ and 40 ng·L(-)¹ in plasma and between 5 ng·L(-)¹ and 20 ng·L(-)¹ in urine). Finally, the highly sensitive validated method was applied to some urine and plasma samples from different donors

    Optical Time-Frequency Packing: Principles, Design, Implementation, and Experimental Demonstration

    Full text link
    Time-frequency packing (TFP) transmission provides the highest achievable spectral efficiency with a constrained symbol alphabet and detector complexity. In this work, the application of the TFP technique to fiber-optic systems is investigated and experimentally demonstrated. The main theoretical aspects, design guidelines, and implementation issues are discussed, focusing on those aspects which are peculiar to TFP systems. In particular, adaptive compensation of propagation impairments, matched filtering, and maximum a posteriori probability detection are obtained by a combination of a butterfly equalizer and four 8-state parallel Bahl-Cocke-Jelinek-Raviv (BCJR) detectors. A novel algorithm that ensures adaptive equalization, channel estimation, and a proper distribution of tasks between the equalizer and BCJR detectors is proposed. A set of irregular low-density parity-check codes with different rates is designed to operate at low error rates and approach the spectral efficiency limit achievable by TFP at different signal-to-noise ratios. An experimental demonstration of the designed system is finally provided with five dual-polarization QPSK-modulated optical carriers, densely packed in a 100 GHz bandwidth, employing a recirculating loop to test the performance of the system at different transmission distances.Comment: This paper has been accepted for publication in the IEEE/OSA Journal of Lightwave Technolog

    Surgical treatment of gastrointestinal stromal tumors of the duodenum. A literature review

    Get PDF
    Background: Gastrointestinal stromal tumors (GIST) are the most frequent mesenchymal tumours in the digestive tract. The duodenal GIST (dGIST) is the rarest subtype, representing only 4–5% of all GIST, but up to 21% of the resected ones. The diagnostic and therapeutic management of dGIST may be difficult due to the rarity of this tumor, its anatomical location, and the clinical behavior that often mimic a variety of conditions; moreover, there is lack of consent for their treatment. This study has evaluated the scientific literature to provide consensus on the diagnosis of dGIST and to outline possible options for surgical treatment. Methods: An extensive research has been carried out on the electronic databases MEDLINE, Scopus, EMBASE and Cochrane to identify all clinical trials that report an event or case series of dGIST. Results: Eighty-six studies that met the inclusion criteria were identified with five hundred forty-nine patients with dGIST: twenty-seven patients were treated with pancreatoduodenectomy and ninety-six with only local resection (segmental/wedge resections); in four hundred twenty-six patients it is not possible identify the type of treatment performed (pancreatoduodenectomy or segmental/wedge resections). Conclusions: dGISTs are a very rare subset of GISTs. They may be asymptomatic or may involve symptoms of upper GI bleeding and abdominal pain at presentation. Because of the misleading clinical presentation the differential diagnosis may be difficult. Tumours smaller than 2 cm have a low biological aggressiveness and can be followed annually by endoscopic ultrasound. The biggest ones should undergo radical surgical resection (R0). In dGIST there is no uniformly adopted surgical strategy because of the low incidence, lack of experience, and the complex anatomy of the duodenum. Therefore, individually tailored surgical approach is recommended. R0 resection with 1–2 cm clear margin is required. Lymph node dissection is not recommended due to the low incidence of lymphatic metastases. Tumor rupture should be avoided

    Current status of the self-expandable metal stent as a bridge to surgery versus emergency surgery in colorectal cancer. Results from an updated systematic review and meta-analysis of the literature

    Get PDF
    Background: The current use of endoscopic stenting as a bridge to surgery is not always accepted in standard clinical practice to treat neoplastic colonic obstructions. Objectives: The role of colonic self-expandable metal stent (SEMS) positioning as a bridge to resective surgery versus emergency surgery (ES) for malignant obstruction, using all new data and available variables, was studied and we focused on short- and long-term results. Materials and Methods: A systematic review with meta-analysis was performed. PubMed, SCOPUS and Web of Science databases were included. The search comprised only randomized controlled trials (RCTs) investigating the interventions that included SEMS positioning versus ES. The primary outcomes were the rates of overall postoperative mortality, clinical and technical success. The secondary outcomes were the short- and long-term results. Results: A total of 12 studies were eligible for further analyses. A laparoscopic colectomy was the most common operation performed in the SEMS group, whereas the traditional open approach was commonly used in the ES group. Intraoperative colonic lavage was seldomly performed during ES. There were no differences in mortality rates between the two groups (RR 1.06, 95% CI 0.55 to 2.04; I2 = 0%). In the SEMS group, the rate of successful primary anastomosis was significantly higher in of SEMS (69.75%) than in the ES (55.07%) (RR 1.26, 95% 245 CI 1.01 to 1.57; I2 = 86%). Conversely, the upfront Hartmann procedure was performed more frequently in the ES (39.1%) as compared to the SEMS group (23.4%) (RR 0.61, 95% CI 0.45 to 0.85; I2 = 23%). The overall postoperative complications rate was significantly lower in the SEMS group (32.74%) than in the ES group (48.25%) (RR 0.61, 95% CI 0.41 to 0.91; I2 = 65%). Conclusions: In the presence of malignant colorectal obstruction, SEMS is safe and associated with the same mortality and significantly lower morbidity than the ES group. The rate of successful primary anastomosis was significantly higher than the ES group. Nevertheless, recurrence and survival outcomes are not significantly different between the two groups. The analysis of short- and long-term results can suggest the use of SEMS as a bridge to resective surgery when it is performed by an endoscopist with adequate expertise in both colonoscopy and fluoroscopic techniques and who performed commonly colonic stenting

    Compression of the inferior vena cava in bowel obstruction

    Get PDF
    INTRODUCTION: We investigated whether (a) the inferior vena cava (IVC) is compressed in bowel obstruction and (b) some tracts are more compressed than others. METHODS: Two groups of abdominal computed tomography (CT) examinations were collected retrospectively. Group O (N = 69) scans were positive for bowel obstruction, group C (N = 50) scans were negative for diseases. IVC anteroposterior and lateral diameters (APD, LAD) were assessed at seven levels. RESULTS: In group C, IVC section had an elliptic shape (APD/LAD: .76 \ub1 .14), the area of which increased gradually from 1.9 (confluence of the iliac veins) to 3.1\u2009cm\ub2/m\ub2 of BSA (confluence of the hepatic veins) with a significant narrowing in the hepatic section. In group O, bowel obstruction caused a compression of IVC (APD/LAD: .54 \ub1 .17). Along its course, IVC section area increased from 1.3 to 2.5\u2009cm\ub2/m\ub2. At ROC curve analysis, an APD/LAD ratio lower than 0.63 above the confluence of the iliac veins discriminated between O and C groups with sensitivity of 74% and specificity of 96%. CONCLUSIONS: Bowel obstruction caused a compression of IVC, which involved its entire course except for the terminal section. APD/LAD ratio may be useful to monitor the degree of compression
    • …
    corecore