74 research outputs found

    False-negative PD-L1 immunostaining in ethanol-fixed EBUS-TBNA specimens of non-small cell lung cancer patients

    Get PDF
    Aims Programmed death-ligand 1 (PD-L1) immunostaining is used to predict which non-small-cell lung cancer (NSCLC) patients will respond best to treatment with programmed cell death protein 1/PD-L1 inhibitors. PD-L1 immunostaining is sometimes performed on alcohol-fixed cytological specimens instead of on formalin-fixed paraffin-embedded (FFPE) biopsies or resections. We studied whether ethanol prefixation of clots from endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) results in diminished PD-L1 immunostaining as compared with formalin fixation. Methods and results FFPE cell blocks from EBUS-TBNA specimens of 54 NSCLC patients were identified. For each case, paired samples were available, consisting of clots directly immersed in formalin and clots prefixed in Fixcyt (50% ethanol). Serial sections were immunostained for PD-L1 by use of the standardised SP263 assay and the 22C3 antibody as a laboratory-developed test (LDT). PD-L1 positivity was determined with two cut-offs (1% and 50%). Concordance of PD-L1 positivity between the formalin-fixed (gold standard) and ethanol-prefixed material was assessed. When the 22C3 LDT was used, 30% and 36% of the ethanol-prefixed specimens showed false-negative results at the 1% and 50% cut-offs, respectively (kappa 0.64 and 0.68). When SP263 was used, 22% of the ethanol-prefixed specimens showed false-negative results at the 1% cut-off (kappa 0.67). At the 50% cut-off, concordance was higher (kappa 0.91), with 12% of the ethanol-prefixed specimens showing false-negative results. Conclusion Ethanol fixation of EBUS-TBNA specimens prior to formalin fixation can result in a considerable number of false-negative PD-L1 immunostaining results when a 1% cut-off is used and immunostaining is performed with SP263 or the 22C3 LDT. The same applies to use of the 50% cut-off when immunostaining is performed with the 22C3 LDT

    Ecological Guild Evolution and the Discovery of the World's Smallest Vertebrate

    Get PDF
    Living vertebrates vary drastically in body size, yet few taxa reach the extremely minute size of some frogs and teleost fish. Here we describe two new species of diminutive terrestrial frogs from the megadiverse hotspot island of New Guinea, one of which represents the smallest known vertebrate species, attaining an average body size of only 7.7 mm. Both new species are members of the recently described genus Paedophryne, the four species of which are all among the ten smallest known frog species, making Paedophryne the most diminutive genus of anurans. This discovery highlights intriguing ecological similarities among the numerous independent origins of diminutive anurans, suggesting that minute frogs are not mere oddities, but represent a previously unrecognized ecological guild

    Observation of gravitational waves from the coalescence of a 2.5–4.5 M ⊙ compact object and a neutron star

    Get PDF
    We report the observation of a coalescing compact binary with component masses 2.5–4.5 M ⊙ and 1.2–2.0 M ⊙ (all measurements quoted at the 90% credible level). The gravitational-wave signal GW230529_181500 was observed during the fourth observing run of the LIGO–Virgo–KAGRA detector network on 2023 May 29 by the LIGO Livingston observatory. The primary component of the source has a mass less than 5 M ⊙ at 99% credibility. We cannot definitively determine from gravitational-wave data alone whether either component of the source is a neutron star or a black hole. However, given existing estimates of the maximum neutron star mass, we find the most probable interpretation of the source to be the coalescence of a neutron star with a black hole that has a mass between the most massive neutron stars and the least massive black holes observed in the Galaxy. We provisionally estimate a merger rate density of 55−47+127Gpc−3yr−1 for compact binary coalescences with properties similar to the source of GW230529_181500; assuming that the source is a neutron star–black hole merger, GW230529_181500-like sources may make up the majority of neutron star–black hole coalescences. The discovery of this system implies an increase in the expected rate of neutron star–black hole mergers with electromagnetic counterparts and provides further evidence for compact objects existing within the purported lower mass gap

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Overall survival with adjuvant atezolizumab after chemotherapy in resected stage II-IIIA non-small-cell lung cancer (IMpower010): a randomised, multicentre, open-label, phase III trial.

    No full text
    BACKGROUND: IMpower010 (NCT02486718) demonstrated significantly improved disease-free survival (DFS) with adjuvant atezolizumab versus best supportive care (BSC) following platinum-based chemotherapy in the programmed death-ligand 1 (PD-L1)-positive and all stage II-IIIA non-small-cell lung cancer (NSCLC) populations, at the DFS interim analysis. Results of the first interim analysis of overall survival (OS) are reported here. PATIENT AND METHODS: The design, participants, and primary-endpoint DFS outcomes have been reported for this phase III, open-label, 1 : 1 randomised study of atezolizumab (1200 mg q3w; 16 cycles) versus BSC after adjuvant platinum-based chemotherapy (1-4 cycles) in adults with completely resected stage IB (≄4 cm)-IIIA NSCLC (per the Union Internationale Contre le Cancer and American Joint Committee on Cancer staging system, 7th edition). Key secondary endpoints included OS in the stage IB-IIIA intent-to-treat (ITT) population and safety in randomised treated patients. The first pre-specified interim analysis of OS was conducted after 251 deaths in the ITT population. Exploratory analyses included OS by baseline PD-L1 expression level (SP263 assay). RESULTS: At a median of 45.3 months\u27 follow-up on 18 April 2022, 127 of 507 patients (25%) in the atezolizumab arm and 124 of 498 (24.9%) in the BSC arm had died. The median OS in the ITT population was not estimable; the stratified hazard ratio (HR) was 0.995 [95% confidence interval (CI) 0.78-1.28]. The stratified OS HRs (95% CI) were 0.95 (0.74-1.24) in the stage II-IIIA (n = 882), 0.71 (0.49-1.03) in the stage II-IIIA PD-L1 tumour cell (TC) ≄1% (n = 476), and 0.43 (95% CI 0.24-0.78) in the stage II-IIIA PD-L1 TC ≄50% (n = 229) populations. Atezolizumab-related adverse event incidences remained unchanged since the previous analysis [grade 3/4 in 53 (10.7%) and grade 5 in 4 (0.8%) of 495 patients, respectively]. CONCLUSIONS: Although OS remains immature for the ITT population, these data indicate a positive trend favouring atezolizumab in PD-L1 subgroup analyses, primarily driven by the PD-L1 TC ≄50% stage II-IIIA subgroup. No new safety signals were observed after 13 months\u27 additional follow-up. Together, these findings support the positive benefit-risk profile of adjuvant atezolizumab in this setting
    • 

    corecore