758 research outputs found

    Spatial interference from well-separated condensates

    Get PDF
    We use magnetic levitation and a variable-separation dual optical plug to obtain clear spatial interference between two condensates axially separated by up to 0.25 mm -- the largest separation observed with this kind of interferometer. Clear planar fringes are observed using standard (i.e. non-tomographic) resonant absorption imaging. The effect of a weak inverted parabola potential on fringe separation is observed and agrees well with theory.Comment: 4 pages, 5 figures - modified to take into account referees' improvement

    Frictional quantum decoherence

    Full text link
    The dynamics associated with a measurement-based master equation for quantum Brownian motion are investigated. A scheme for obtaining time evolution from general initial conditions is derived. This is applied to analyze dissipation and decoherence in the evolution of both a Gaussian and a Schr\"{o}dinger cat initial state. Dependence on the diffusive terms present in the master equation is discussed with reference to both the coordinate and momentum representations.Comment: 18 pages, 7 figure

    Ultra-low noise, bi-polar, programmable current sources

    Get PDF
    We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the device specifications make them potentially useful in a range of applications. The devices feature a bi-directional current range of ±\pm~10~mA and ±\pm~250~mA respectively on three independent channels with 16-bit resolution. Both devices feature narrow 1/f noise bandwidth of 1~Hz, enabling magnetic field manipulation for high-performance OPMs. They exhibit low noise of 146.3~pA/Hz\sqrt{\mathrm{Hz}} and 4114~pA/Hz\sqrt{\mathrm{Hz}} which translates to 14.57~ppb/Hz\sqrt{\mathrm{Hz}} and 16.46~ppb/Hz\sqrt{\mathrm{Hz}} noise relative to full scale.Comment: 9 pages, 9 figure

    Parameterized bounded-depth Frege is not optimal

    Get PDF
    A general framework for parameterized proof complexity was introduced by Dantchev, Martin, and Szeider [9]. There the authors concentrate on tree-like Parameterized Resolution-a parameterized version of classical Resolution-and their gap complexity theorem implies lower bounds for that system. The main result of the present paper significantly improves upon this by showing optimal lower bounds for a parameterized version of bounded-depth Frege. More precisely, we prove that the pigeonhole principle requires proofs of size n in parameterized bounded-depth Frege, and, as a special case, in dag-like Parameterized Resolution. This answers an open question posed in [9]. In the opposite direction, we interpret a well-known technique for FPT algorithms as a DPLL procedure for Parameterized Resolution. Its generalization leads to a proof search algorithm for Parameterized Resolution that in particular shows that tree-like Parameterized Resolution allows short refutations of all parameterized contradictions given as bounded-width CNF's

    It Must be Awful for Them: Perspective and Task Context Affects Ratings for Health Conditions

    Get PDF
    When survey respondents rate the quality of life (QoL) associated with a health condition, they must not only evaluate the health condition itself, but must also interpret the meaning of the rating scale in order to assign a specific value. The way that respondents approach this task depends on subjective interpretations, resulting in inconsistent results across populations and tasks. In particular, patients and non-patients often give very different ratings to health conditions, a discrepancy that raises questions about the objectivity of either groups\u27 evaluations. In this study, we found that the perspective of the raters (i.e., their own current health relative to the health conditions they rated) influences the way they distinguish between different health states that vary in severity. Consistent with prospect theory, a mild and a severe lung disease scenario were rated quite differently by lung disease patients whose own health falls between the two scenarios, whereas healthy non-patients, whose own health was better than both scenarios, rated the two scenarios as much more similar. In addition, we found that the context of the rating task influences the way participants distinguish between mild and severe scenarios. Both patients and non-patients gave less distinct ratings to the two scenarios when each were presented in isolation than when they were presented alongside other scenarios that provided contextual information about the possible range of severity for lung disease. These results raise continuing concerns about the reliability and validity of subjective QoL ratings, as these ratings are highly sensitive to differences between respondent groups and the particulars of the rating task

    A note on light velocity anisotropy

    Get PDF
    It is proved that in experiments on or near the Earth, no anisotropy in the one-way velocity of light may be detected. The very accurate experiments which have been performed to detect such an effect are to be considered significant tests of both special relativity and the equivalence principleComment: 8 pages, LaTex, Gen. Relat. Grav. accepte

    Design and fabrication of diffractive atom chips for laser cooling and trapping

    Get PDF
    It has recently been shown that optical reflection gratings fabricated directly into an atom chip provide a simple and effective way to trap and cool substantial clouds of atoms [1,2]. In this article we describe how the gratings are designed and micro-fabricated and we characterise their optical properties, which determine their effectiveness as a cold atom source. We use simple scalar diffraction theory to understand how the morphology of the gratings determines the power in the diffracted beams

    Optical characterisation of micro-fabricated Fresnel zone plates for atomic waveguides

    Get PDF
    We optically assess Fresnel zone plates (FZPs) that are designed to guide cold atoms. Imaging of various ring patterns produced by the FZPs gives an average RMS error in the brightest part of the ring of 3% with respect to trap depth. This residue is attributed to the imaging system, incident beam shape and FZP manufacturing tolerances. Axial propagation of the potentials is presented experimentally and through numerical simulations, illustrating prospects for atom guiding without requiring light sheets
    corecore