41 research outputs found

    A low background Micromegas detector for the CAST experiment

    Full text link
    A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection (5×1055\times 10^{-5} counts keV1^{-1}cm2^{-2}s1^{-1}) thanks to its good spatial and energy resolution as well as the low radioactivity materials used in the construction of the detector. For the second phase of the experiment (2005-2007), the detector will be upgraded by adding a shielding and including focusing optics. These improvements should allow for a background rejection better than two orders of magnitude.Comment: 6 pages, 3 figures To appear on the proceedings of the 9th ICATPP Conference on AStroparticle, Particle, Space Physics, Detectors and Medical Physics Application

    The CLAS12 Forward Tagger

    Get PDF
    This document presents the technical layout and the performance of the CLAS12 Forward Tagger (FT). The FT, composed of an electromagnetic calorimeter based on PbWO4 crystals (FT-Cal), a scintillation hodoscope (FT-Hodo), and several layers of Micromegas trackers (FT-Trk), has been designed to detect electrons and photons scattered at polar angles from 2∘ to 5∘ and to meet the physics goals of the hadron spectroscopy program and other experiments running with the CLAS12 spectrometer in Hall B

    Micromegas at low pressure for beam tracking

    No full text
    International audienceNew facilities like FAIR at GSI or SPIRAL2 at GANIL, will provide radioactive ion beams at low energies (less than 10MeV/n). Such beams have generally a large emittance, which requires the use of beam tracking detectors to reconstruct the exact trajectories of the nuclei. To avoid the angular and energy straggling that classical beam tracking detectors would generate in the beam due to their thickness, we propose the use of SED (Secondary Electron Detectors). It consists of a low pressure gaseous detector placed outside the beam coupled to an emissive foil in the beam. Since 2008, different low pressure gaseous detectors (wire chambers and micromegas) have been constructed and tested. The performances achievable at low pressure are similar to or even better than the ones at atmospheric pressure. The fast charge collection leads to excellent timing properties as well as high counting rate capabilities. Several micromegas at low pressure were tested in the laboratory demonstrating a good time resolution, 130±30 ps, which is compatible with the results obtained with wire chambers

    Development of a Tracking System of Exotic Nuclear Beams for FAIR

    No full text
    International audienceNew accelerators like SPIRAL2 (GANIL, France) or FAIR (GSI, Germany) will be soon constructed, and they will be able to produce radioactive ion beams (RIB) with high intensities of current (>=106 pps). These beams, at low energy, lower than 20 MeV/n, usually have high emittance, which imposes the use of tracking detectors before the target in order to reconstruct the trajectory of the ions. The group of Nuclear Physics at CNA (Centro Nacional de Aceleradores), is in charge of developing a tracking system for the low energy branch of FAIR (the HISPEC/DESPEC project). A collaboration with CEA-SACLAY was established, with the aim of developing, building and testing low pressure Secondary electron Detectors (SeD). Within this proposal we have projected and constructed a new Nuclear Physics Line in the CNA in order to be able to receive any kind of detector tests and the associated nuclear instruments

    Secondary electrons detectors for beam tracking: micromegas and wire chamber

    No full text
    International audienceSPIRAL2 or FAIR will be able to deliver beams of radioactive isotopes of low energy (less than 10MeV/n). The emittance of these new beams will impose the use of beam tracking detectors to reconstruct the exact impact position of the nuclei on the experimental target. However, due to their thickness, the classical detectors will generate a lot of energy and angular straggling. A possible alternative is the SED principle (Secondary Electron Detector). It consists of an emissive foil placed in beam and a detector for the secondary electrons ejected by the passing of the nuclei through the foil. An R&D program has been initiated at CEA Saclay to study the possibility to use low pressure gaseous detectors as SED for beam tracking. Some SED have been already used on the VAMOS spectrometer at GANIL since 2004. We have constructed new detectors on this model to measure their performances in time and spatial resolution, and counting rate. Other detector types are also under study. For the first time, a test with different micromegas detectors at 4 Torr has been realized. A comparison on the time resolution has been performed between wire chamber and micromegas at very low pressure. The use of micromegas could be promising to improve the counting rate capability and the robustness of beam tracking detectors

    Large resistive 2D Micromegas with genetic multiplexing and some imaging applications

    No full text
    International audienceThe performance of the first large resistive Micromegas detectors with 2D readout and genetic multi-plexing is presented. These detectors have a × 50 50cm 2 active area and are equipped with 1024 strips both in X-and Y-directions. The same genetic multiplexing pattern is applied on both coordinates, resulting in the compression of signals on × 2 61 readout channels. Four such detectors have been built at CERN, and extensively tested with cosmics. The resistive strip film allows for very high gain operation, compensating for the charge spread on the 2 dimensions as well as the S N / loss due to the huge, 1 nF input capacitance. This film also creates a significantly different signal shape in the X-and Y-coordinates due to the charge evacuation along the resistive strips. All in all a detection efficiency above 95% is achieved with a 1 cm drift gap. Though not yet optimal, the measured 300 mm spatial resolution allows for very precise imaging in the field of muon tomography, and some applications of these detectors are presented

    A Micromegas-based telescope for muon tomography: The WatTo experiment

    No full text
    International audienceThis paper reports about the first Micromegas-based telescope built for applications in muon tomo-graphy. The telescope consists of four, 50 Â 50 cm 2 resistive multiplexed Micromegas with a 2D layout and a self-triggering electronics based on the Dream chip. Thanks to the multiplexing, the four detectors were readout with a single Front-End Unit. The high voltages were provided by a dedicated card using low consumption CAEN miniaturized modules. A nano-PC (Hummingboard) ensured the HV control and monitoring coupled with a temperature feedback as well as the data acquisition and storage. The overall consumption of the instrument yielded 30 W only, i.e. the equivalent of a standard bulb. The telescope was operated outside during 3.5 months to image the water tower of the CEA-Saclay research center, including a 1.5-month campaign with solar panels. The development of autonomous, low consumption muon telescopes with unprecedented accuracy opens new applications in imaging as well as in the field of muon metrology
    corecore