418 research outputs found

    From Practice to Policy to Practice

    Get PDF
    Recent molecular dynamics simulation results have increased conceptual understanding of the grazing and the ploughing friction at elevated temperatures, particularly near the substrate's melting point. In this commentary we address a major constraint concerning its experimental verification

    Atomistic aspects of ductile responses of cubic silicon carbide during nanometric cutting

    Get PDF
    Cubic silicon carbide (SiC) is an extremely hard and brittle material having unique blend of material properties which makes it suitable candidate for microelectromechanical systems and nanoelectromechanical systems applications. Although, SiC can be machined in ductile regime at nanoscale through single-point diamond turning process, the root cause of the ductile response of SiC has not been understood yet which impedes significant exploitation of this ceramic material. In this paper, molecular dynamics simulation has been carried out to investigate the atomistic aspects of ductile response of SiC during nanometric cutting process. Simulation results show that cubic SiC undergoes sp3-sp2 order-disorder transition resulting in the formation of SiC-graphene-like substance with a growth rate dependent on the cutting conditions. The disorder transition of SiC causes the ductile response during its nanometric cutting operations. It was further found out that the continuous abrasive action between the diamond tool and SiC causes simultaneous sp3-sp2 order-disorder transition of diamond tool which results in graphitization of diamond and consequent tool wear

    EPR-based ghost imaging using a single-photon-sensitive camera

    Get PDF
    Correlated photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments, two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated photon ghost imaging experiments have scanned a single-pixel detector through the field of view to obtain spatial information. However, scanning leads to poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work, we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far field of the photon pair source, taking advantage of the Einstein–Podolsky–Rosen-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing

    Patient specific modeling of palpation-based prostate cancer diagnosis: effects of pelvic cavity anatomy and intrabladder pressure.

    Get PDF
    Computational modeling has become a successful tool for scientific advances including understanding the behavior of biological and biomedical systems as well as improving clinical practice. In most cases, only general models are used without taking into account patient-specific features. However, patient specificity has proven to be crucial in guiding clinical practice because of disastrous consequences that can arise should the model be inaccurate. This paper proposes a framework for the computational modeling applied to the example of the male pelvic cavity for the purpose of prostate cancer diagnostics using palpation. The effects of patient specific structural features on palpation response are studied in three selected patients with very different pathophysiological conditions whose pelvic cavities are reconstructed from MRI scans. In particular, the role of intrabladder pressure in the outcome of digital rectal examination is investigated with the objective of providing guidelines to practitioners to enhance the effectiveness of diagnosis. Furthermore, the presence of the pelvic bone in the model is assessed to determine the pathophysiological conditions in which it has to be modeled. The conclusions and suggestions of this work have potential use not only in clinical practice and also for biomechanical modeling where structural patient-specificity needs to be considered. © 2015 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd

    Evaluating a new generation of wearable high-density diffuse optical tomography (HD-DOT) technology via retinotopic mapping in the adult brain

    Get PDF
    We investigated the performance of a novel HD-DOT system by replicating a series of classic visual stimulation paradigms. Haemodynamic response functions and cortical activation maps replicated the results obtained with larger fibre-based systems

    Quantitative mechanical assessment of the whole prostate gland ex vivo using dynamic instrumented palpation

    Get PDF
    An instrumented palpation sensor, designed for measuring the dynamic modulus of tissue in vivo, has been developed and trialled on ex vivo whole prostate glands. The sensor consists of a flexible membrane sensor/actuator with an embedded strain gauge and is actuated using a dynamically varying airflow at frequencies of 1 and 5 Hz. The device was calibrated using an indentation stiffness measurement rig and gelatine samples with a range of static modulus similar to that reported in the literature for prostate tissue. The glands were removed from patients with diagnosed prostate cancer scheduled for radical prostatectomy, and the stiffness was measured within 30 min of surgical removal. Each prostate was later examined histologically in a column immediately below each indentation point and graded into one of the four groups; normal, benign prostatic hyperplasia, cancerous and mixed cancer and benign prostatic hyperplasia. In total, 11 prostates were assessed using multiple point probing, and the complex modulus at 1 and 5 Hz was calculated on a point-by-point basis. The device yielded values of quasi-static modulus of 15 ± 0.5 kPa and dynamic modulus of 20 ± 0.5 kPa for whole prostates, and a sensitivity of up to 80% with slightly lower specificity was achieved on diagnosis of prostate cancer using a combination of mechanical measures. This assessment did not take into account some obvious factors such as edge effects, overlap and clinical significance of the cancer, all of which would improve performance. The device, as currently configured, is immediately deployable in vivo. A number of improvements are also identified which could improve the sensitivity and specificity in future embodiments of the probe
    • …
    corecore