9 research outputs found

    EVALUACI脫N DE PROBLEMAS DE CORROSI脫N EN REACTORES ANAEROBIOS PARA DEPURACI脫N DE AGUAS RESIDUALES

    Get PDF
    Corrosion problems presented in Rio Frio Wastewater Treatment Plant (PTAR), which belong to the Regional Autonomous Corporation, and are in charge of treatment of the wastewater of Bucaramanga's south zone, were analyzed in this study. A preliminary inspection was carried out to the PTAR, for determining test zones and the advance of corrosion in the structure of UASB reactors. Carbonation, chlorides concentration and sulphate tests were determined in two of three UASB reactors existing in the plant, inside and in the top corresponding to settlers zone. The time in that the carbonatation and chloride ions will reach the reactors reinforcement, was predicted and from the profile of chlorides concentration measured in every sample the diffusion coefficients of chloride and sulphate ions in the structure were calculated. Diffusion tests and injection cells were carried out; in the laboratory; cement mortar type V was used in the former and simulated solutions of concrete with CI" and S04= ions. In the injection cells was used steel rod type A-37 and PDR-60 and Polarization Resistance (Rp) curves were carried out daily.En esta investigaci贸n se analizaron los problemas de corrosi贸n presentados en la Planta de Tratamiento de Aguas Residuales (PTAR) de R铆o Fr铆o, perteneciente a la Corporaci贸n Aut贸noma Regional, que es la encargada de tratar las aguas residuales de la zona sur de Bucaramanga, Colombia. Se realiz贸 una inspecci贸n preliminar a la PTAR, para definir zonas a muestrear y avance de la corrosi贸n en la estructura de los reactores UASB. Se hicieron pruebas de carbonataci贸n, concentraci贸n de cloruros y sulfatos en dos de los tres reactores UASB existentes en la planta, en su interior y en la parte superior correspondiente a la zona de sedimentadores. Adem谩s se hizo la predicci贸n del tiempo en el que la carbonataci贸n y los iones cloruro alcanzar谩n la armadura de los reactores, y con el perfil de concentraci贸n medido en cada testigo se calcularon los coeficientes de difusi贸n de los iones cloruro y sulfato a trav茅s de la estructura. A nivel de laboratorio se realizaron pruebas de celdas de difusi贸n y celdas de inyecci贸n; en la primera se utilizaron morteros de cemento tipo V y soluciones simuladas de concreto con iones CI" y S04". En las celdas de inyecci贸n se utilizaron varillas de acero tipo A-37 y PDR-60 y se realizaron ensayos de resistencia a la polarizaci贸n (Rp) diariamente. El problema que se ha trabajado en este caso ha sido poco tratado en la literatura y el desarrollo de la metodolog铆a para abordarlo es una contribuci贸n importante a la ingenier铆a de la corrosi贸n. &nbsp

    EVALUACI脫N DE PROBLEMAS DE CORROSI脫N EN REACTORES ANAEROBIOS PARA DEPURACI脫N DE AGUAS RESIDUALES

    No full text
    Corrosion problems presented in Rio Frio Wastewater Treatment Plant (PTAR), which belong to the Regional Autonomous Corporation, and are in charge of treatment of the wastewater of Bucaramanga's south zone, were analyzed in this study. A preliminary inspection was carried out to the PTAR, for determining test zones and the advance of corrosion in the structure of UASB reactors. Carbonation, chlorides concentration and sulphate tests were determined in two of three UASB reactors existing in the plant, inside and in the top corresponding to settlers zone. The time in that the carbonatation and chloride ions will reach the reactors reinforcement, was predicted and from the profile of chlorides concentration measured in every sample the diffusion coefficients of chloride and sulphate ions in the structure were calculated. Diffusion tests and injection cells were carried out; in the laboratory; cement mortar type V was used in the former and simulated solutions of concrete with CI" and S04= ions. In the injection cells was used steel rod type A-37 and PDR-60 and Polarization Resistance (Rp) curves were carried out daily.En esta investigaci贸n se analizaron los problemas de corrosi贸n presentados en la Planta de Tratamiento de Aguas Residuales (PTAR) de R铆o Fr铆o, perteneciente a la Corporaci贸n Aut贸noma Regional, que es la encargada de tratar las aguas residuales de la zona sur de Bucaramanga, Colombia. Se realiz贸 una inspecci贸n preliminar a la PTAR, para definir zonas a muestrear y avance de la corrosi贸n en la estructura de los reactores UASB. Se hicieron pruebas de carbonataci贸n, concentraci贸n de cloruros y sulfatos en dos de los tres reactores UASB existentes en la planta, en su interior y en la parte superior correspondiente a la zona de sedimentadores. Adem谩s se hizo la predicci贸n del tiempo en el que la carbonataci贸n y los iones cloruro alcanzar谩n la armadura de los reactores, y con el perfil de concentraci贸n medido en cada testigo se calcularon los coeficientes de difusi贸n de los iones cloruro y sulfato a trav茅s de la estructura. A nivel de laboratorio se realizaron pruebas de celdas de difusi贸n y celdas de inyecci贸n; en la primera se utilizaron morteros de cemento tipo V y soluciones simuladas de concreto con iones CI" y S04". En las celdas de inyecci贸n se utilizaron varillas de acero tipo A-37 y PDR-60 y se realizaron ensayos de resistencia a la polarizaci贸n (Rp) diariamente. El problema que se ha trabajado en este caso ha sido poco tratado en la literatura y el desarrollo de la metodolog铆a para abordarlo es una contribuci贸n importante a la ingenier铆a de la corrosi贸n. &nbsp
    corecore