16 research outputs found

    Various simulated body fluids lead to significant differences in collagen tissue engineering scaffolds

    Get PDF
    This study aims to point out the main drawback with respect to the design of simulated body environments. Three media commonly used for the simulation of the identical body environment were selected, i.e., Kokubo's simulated body fluid that simulates the inorganic component of human blood plasma, human blood plasma, and phosphate buffer saline. A comparison was performed of the effects of the media on collagen scaffolds. The mechanical and structural effects of the media were determined via the application of compression mechanical tests, the determination of mass loss, and image and micro-CT analyses. The adsorption of various components from the media was characterized employing energy-dispersive spectrometry. The phase composition of the materials before and after exposure was determined using X-ray diffraction. Infrared spectroscopy was employed for the interpretation of changes in the collagen secondary structure. Major differences in terms of the mechanical properties and mass loss were observed between the three media. Conversely, only minor structural changes were detected. Since no general recommendation exists for selecting the simulated body environment, it is necessary to avoid the simplification of the results and, ideally, to utilize alternative methods to describe the various aspects of degradation processes that occur in the media.Web of Science1416art. no. 438

    není uveden

    No full text
    In the thesis the author deals with the surgical technique of the genioglossus advancement and hyoid myotomy (GAHM) in the obstructive sleep apnoea syndrome (OSAS) therapy. He focuses in particular on methods used to widen the upper airway by surgical modification of facial bones. Following the definition of the research objective in Chapter 1 and the general introduction in Chapter 2, we can find in Chapter 3 the description and definition of OSAS as well as physiological, pathophysiological and epidemiological notes on sleep, ventilation in sleep and OSAS. In Chapter 4 the author recommends some new methods of examining the upper airway that can be applied in an ordinary dental surgery to predict the risk of development or occurrence of OSAS in some patients. Chapter 5 includes an overview of therapeutic options for OSAS and a detailed description of different GAHM techniques. In accordance with the research objectives and the methodology described in Chapter 6, the results in Chapter 7 show, for a large sample of examined patients, the dependence of obesity (as expressed by the BMI) on the severity of OSAS, along with some cephalometric values in which such dependence has not been published so far. Then the chapter documents a high success rate of GAHM treatment of OSAS in operated patients. This is so,..

    Note on the use of different approaches to determine the pore sizes of tissue engineering scaffolds: what do we measure?

    No full text
    Abstract Background Collagen-based scaffolds provide a promising option for the treatment of bone defects. One of the key parameters of such scaffolds consists of porosity, including pore size. However, to date, no agreement has been found with respect to the methodology for pore size evaluation. Since the determination of the exact pore size value is not possible, the comparison of the various methods applied is complicated. Hence, this study focuses on the comparison of two widely-used methods for the characterization of porosity—scanning electron microscopy (SEM) and micro-computed tomography (micro-CT). Methods 7 types of collagen-based composite scaffold models were prepared by means of lyophilization and collagen cross-linking. Micro-CT analysis was performed in 3D and in 2D (pore size parameters were: major diameter, mean thickness, biggest inner circle diameter and area-equivalent circle diameter). Afterwards, pore sizes were analyzed in the same specimens by an image analysis of SEM microphotographs. The results were statistically evaluated. The comparison of the various approaches to the evaluation of pore size was based on coefficients of variance and the semi-quantitative assessment of selected qualities (e.g. the potential for direct 3D analysis, whole specimen analysis, non-destructivity). Results The pore size values differed significantly with respect to the parameters applied. Median values of pore size values were ranging from 20 to 490 µm. The SEM values were approximately 3 times higher than micro-CT 3D values for each specimen. The Mean thickness was the most advantageous micro-CT 2D approach. Coefficient of variance revealed no differences among pore size parameters (except major diameter). The semi-quantitative comparison approach presented pore size parameters in descending order with regard to the advantages thereof as follows: (1) micro-CT 3D, (2) mean thickness and SEM, (3) biggest inner circle diameter, major diameter and area equivalent circle diameter. Conclusion The results indicated that micro-CT 3D evaluation provides the most beneficial overall approach. Micro-CT 2D analysis (mean thickness) is advantageous in terms of its time efficacy. SEM is still considered as gold standard for its widespread use and high resolution. However, exact comparison of pore size analysis in scaffold materials remains a challenge

    Osteoarthrosis of Temporomandibular Joint Related to the Defects of Posterior Dentition: A Retrospective Study

    No full text
    Osteoarthrosis (OA) of temporomandibular joint (TMJ) is a progressive degenerative disease, gradually affecting cartilage, synovial membrane and bone structures. OA of TMJ clinically manifests with joint noises, pain and restricted mouth opening. In late stages, it results in severe damage of TMJ structures and development of ankylosis. Osteoarthrosis is a multifactorial disease; the occurrence is associated with TMJ overloading. The cohort included 619 patients [538 women (87%) and 81 men (13%), with average age 40.6 years (age range 8–89 years)] with TMJ disorder, who were examined in the year 2014 in Department of Dental Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic. The aim of this retrospective study was to analyse, if the lack of posterior teeth (supporting teeth zones) is the main etiologic factor of osteoarthrosis of TMJ. Diagnosis of OA was established on the clinical signs and the panoramic X-ray signs. Simultaneously other etiologic factors of OA were assessed. The presence of OA changes on X-ray had 171 patients (i.e. 27.6% of the total number of 619). 17.5% from these patients with OA had defect in posterior dentition. Other aetiological factors (stress, skeletal or vertebrogenous disorders) showed higher incidence of OA changes on X-ray. Defect of posterior dentition is not negligible, but it is not the main aetiological factor for osteoarthrosis of TMJ

    Intrusion of overerupted molars with temporary anchorage devices before prosthetic reconstruction: A case report

    No full text
    Abstract Extraction of teeth without adequate prosthetic rehabilitation frequently can lead to overeruption of opposing teeth, which may cause occlusal disturbances and complicate dental restoration. Equilibration with consequent need of endodontic treatment, surgical intrusion or extraction are often indicated as a remedy in such cases. The article proposes a method of orthodontic intrusion with the use of temporary anchorage devices as a predictable and less invasive option. Important clinical aspects of molar intrusion with respect to surrounding anatomical structures are also discussed

    Keratocystic Odontogenic Tumour with Extraosseal Spread: Evaluation of the Effect Carnoy’s Solution

    No full text
    Keratocystic odontogenic tumour is relatively rare benign tumour. It is characterized by its fast aggressive growth and high risk of recurrence. Treatment is always surgical: conservative (enucleation, marsupialization) or aggressive (enucleation followed by application of Carnoy’s solution, cryotherapy; peripheral ostectomy or en block resection of the jaw). Authors analysed retrospectively 22 patients who fulfilled inclusion criteria, i.e. had odontogenic keratocystic tumour of mandible, wherein antero-posterior dimension was at least 30 mm, and the tumour penetrated into the surrounding soft tissues. All patients underwent tumour enucleation, in 11 patients Carnoy’s solution was given into the bone cavity after enucleation. The recurrence rate in the evaluation at least 36 months after surgery was both patient groups the same: 45.4%

    Keratocystic Odontogenic Tumour with Extraosseal Spread: Evaluation of the Effect Carnoy's Solution

    No full text
    Abstract: Keratocystic odontogenic tumour is relatively rare benign tumour. It is characterized by its fast aggressive growth and high risk of recurrence. Treatment is always surgical: conservative (enucleation, marsupialization) or aggressive (enucleation followed by application of Carnoy's solution, cryotherapy; peripheral ostectomy or en block resection of the jaw). Authors analysed retrospectively 22 patients who fulfilled inclusion criteria, i.e. had odontogenic keratocystic tumour of mandible, wherein antero-posterior dimension was at least 30 mm, and the tumour penetrated into the surrounding soft tissues. All patients underwent tumour enucleation, in 11 patients Carnoy's solution was given into the bone cavity after enucleation. The recurrence rate in the evaluation at least 36 months after surgery was both patient groups the same: 45.4%

    The use of sentinel skin islands for monitoring buried and semi-buried micro-vascular flaps. Part I: Summary and brief description of monitoring methods

    No full text
    Micro-vascular flaps have been used for the repair of challenging defects for over 45 years. The risk of failure is reported to be around 5-10% which despite medical and technical advances in recent years remains essentially unchanged. Precise, continuous, sensitive and specific monitoring together with prompt notification of vascular compromise is crucial for the success of the procedure. In this review, we provide a classification and brief description of the reported methods for monitoring the micro-vascular flap and a summary of the benefits over direct visual monitoring. Over 40 different monitoring techniques have been reported but their comparative merits are not always obvious. One looks for early detection of a flap's compromise, improved flap salvage rate and a minimal false-positive or false-negative rate. The cost-effectiveness of any method should also be considered. Direct visualisation of the flap is the method most generally used and still seems to be the simplest, cheapest and most reliable method for flap monitoring. Considering the alternatives, only implantable Doppler ultrasound probes, near infrared spectroscopy and laser Doppler flowmetry have shown any evidence of improved flap salvage rates over direct visual monitoring

    Zn–0.8Mg–0.2Sr (wt.%) Absorbable Screws—An In-Vivo Biocompatibility and Degradation Pilot Study on a Rabbit Model

    No full text
    In this pilot study, we investigated the biocompatibility and degradation rate of an extruded Zn–0.8Mg–0.2Sr (wt.%) alloy on a rabbit model. An alloy screw was implanted into one of the tibiae of New Zealand White rabbits. After 120 days, the animals were euthanized. Evaluation included clinical assessment, microCT, histological examination of implants, analyses of the adjacent bone, and assessment of zinc, magnesium, and strontium in vital organs (liver, kidneys, brain). The bone sections with the implanted screw were examined via scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS). This method showed that the implant was covered by a thin layer of phosphate-based solid corrosion products with a thickness ranging between 4 and 5 µm. Only negligible changes of the implant volume and area were observed. The degradation was not connected with gas evolution. The screws were fibrointegrated, partially osseointegrated histologically. We observed no inflammatory reaction or bone resorption. Periosteal apposition and formation of new bone with a regular structure were frequently observed near the implant surface. The histological evaluation of the liver, kidneys, and brain showed no toxic changes. The levels of Zn, Mg, and Sr after 120 days in the liver, kidneys, and brain did not exceed the reference values for these elements. The alloy was safe, biocompatible, and well-tolerated
    corecore