293 research outputs found

    Factors Affecting Blood Pressure Variability: Lessons Learned from Two Systematic Reviews of Randomized Controlled Trials

    Get PDF
    Systematic reviews can often reveal much more than the original objective of the work. The objectives of this retrospective analysis were to answer three basic questions about blood pressure variability: 1) Does blood pressure entry criterion have an effect on baseline blood pressure variability? 2) Do thiazide diuretics have a significant effect on blood pressure variability? and 3) Does systolic blood pressure vary to the same degree as diastolic blood pressure? This analysis of blood pressure variability is based on resting standardized research setting BP readings from two systematic reviews evaluating blood pressure lowering efficacy of thiazide diuretics from double blind randomized controlled trials in 33,611 patients with primary hypertension. The standard deviation reported in trials was the focus of the research and the unit of analysis. When a threshold systolic or diastolic blood pressure value is used to determine entry into a trial, baseline variability is significantly decreased, systolic from 14.0 to 9.3 mmHg and diastolic from 8.4 to 5.3 mmHg. Thiazides do not change BP variability as the standard deviation and coefficient of variation of systolic blood pressure and diastolic blood pressure did not differ between thiazide and placebo groups at end of treatment. The coefficient of variation of systolic blood pressure was significantly greater than the coefficient of variation of diastolic blood pressure. Entry criterion decreases the baseline blood pressure variability. Treatment with a thiazide diuretic does not affect blood pressure variability. Systolic blood pressure varies to a greater degree than diastolic blood pressure

    Acute myocardial infarction incidence and hospital mortality: routinely collected national data versus linkage of national registers

    Get PDF
    Background and Objective To compare levels of and trends in incidence and hospital mortality of first acute myocardial infarction (AMI) based on routinely collected hospital morbidity data and on linked registers. Cases taken from routine hospital data are a mix of patients with recurrent and first events, and double counting occurs when cases are admitted for an event several times during 1 year. By linkage of registers, recurrent events and double counts can be excluded. Study Design and Setting In 1995 and 2000, 28,733 and 25,864 admissions for AMI were registered in the Dutch national hospital discharge register. Linkage with the population register yielded 21,565 patients with a first AMI in 1995 and 20,414 in 2000. Results In 1995 and 2000, the incidence based on the hospital register was higher than based on the linked registers in men (22% and 23% higher) and women (18% and 20% higher). In both years, hospital mortality based on the hospital register and on linked registers was similar. The decline in incidence between 1995 and 2000 was comparable whether based on standard hospital register data or linked data (18% and 20% in men, 15% and 17% in women). Similarly, the decline in hospital mortality was comparable using either approach (11% and 9% in both men and women). Conclusion Although the incidence based on routine hospital data overestimates the actual incidence of first AMI based on linked registers, hospital mortality and trends in incidence and hospital mortality are not changed by excluding recurrent events and double counts. Since trends in incidence and hospital mortality of AMI are often based on national routinely collected data, it is reassuring that our results indicate that findings from such studies are indeed valid and not biased because of recurrent events and double counts

    Mortality in Dutch hospitals: Trends in time, place and cause of death after admission for myocardial infarction and stroke. An observational study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Patterns in time, place and cause of death can have an important impact on calculated hospital mortality rates. Objective is to quantify these patterns following myocardial infarction and stroke admissions in Dutch hospitals during the period 1996–2003, and to compare trends in the commonly used 30-day in-hospital mortality rates with other types of mortality rates which use more extensive follow-up in time and place of death.</p> <p>Methods</p> <p>Discharge data for all Dutch admissions for index conditions (1996–2003) were linked to the death certification registry. Then, mortality rates within the first 30, 90 and 365 days following admissions were analyzed for deaths occurring within and outside hospitals.</p> <p>Results</p> <p>Most deaths within a year after admission occurred within 30 days (60–70%). No significant trends in this distribution of deaths over time were observed. Significant trends in the distribution over place of death were observed for both conditions. For myocardial infarction, the proportion of deaths after transfer to another hospital has doubled from 1996–2003. For stroke a significant rise of the proportion of deaths outside hospital was found. For MI the proportion of deaths attributed to a circulatory disease has significantly fallen ovtime. Seven types of hospital mortality indicators, different in scope and observation period, all show a drop of hospital mortality for both MI and stroke over the period 1996–2003. For stroke the observed absolute reduction in death rate increases for the first year after admission, for MI the observed drop in 365-day overall mortality almost equals the observed drop in 30-day in hospital mortality over 1996–2003.</p> <p>Conclusion</p> <p>Changes in the timing, place and causes of death following admissions for myocardial infarction and stroke have important implications for the definitions of in-hospital and post-admission mortality rates as measures of hospital performance. Although necessary for understanding mortality patterns over time, including within mortality rates deaths which occur outside hospitals and after longer periods following index admissions remain debatable and may not reflect actual hospital performance but probably mirrors transfer, efficiency, and other health care policies.</p

    Diagnostic accuracy of contrast-enhanced MR angiography in severe carotid stenosis: meta-analysis with metaregression of different techniques

    Get PDF
    Contrast-enhanced magnetic resonance angiography (CE-MRA) has become a well-established noninvasive imaging method for the assessment of severe carotid stenosis (70–99% by NASCET criteria). However, CE-MRA is not a standardised technique, but encompasses different concurrent techniques. This review analyses possible differences. A bivariate random effects meta-analysis of 17 primary diagnostic accuracy studies confirmed a high pooled sensitivity of 94.3% and specificity of 93.0% for carotid CE-MRA in severe carotid stenosis. Sensitivity was fairly uniform among the studies, while specificity showed significant variation (I2 = 73%). Metaregressions found significant differences for specificity with two covariates: specificity was higher when using not only maximum intensity projection (MIP) images, but also three-dimensional (3D) images (P = 0.01). Specificity was also higher with electronic images than with hardcopies (P = 0.02). The timing technique (bolus-timed, fluoroscopically triggered or time-resolved) did not result in any significant differences in diagnostic accuracy. Some nonsignificant trends were found for the percentages of severe carotid disease, acquisition time and voxel size. In conclusion, in CE-MRA of severe carotid stenosis the three major timing techniques yield comparably high diagnostic accuracy, electronic images are more specific than hardcopies, and 3D images should be used in addition to MIP images to increase the specificity

    Rapid Analysis of Vessel Elements (RAVE): A Tool for Studying Physiologic, Pathologic and Tumor Angiogenesis

    Get PDF
    Quantification of microvascular network structure is important in a myriad of emerging research fields including microvessel remodeling in response to ischemia and drug therapy, tumor angiogenesis, and retinopathy. To mitigate analyst-specific variation in measurements and to ensure that measurements represent actual changes in vessel network structure and morphology, a reliable and automatic tool for quantifying microvascular network architecture is needed. Moreover, an analysis tool capable of acquiring and processing large data sets will facilitate advanced computational analysis and simulation of microvascular growth and remodeling processes and enable more high throughput discovery. To this end, we have produced an automatic and rapid vessel detection and quantification system using a MATLAB graphical user interface (GUI) that vastly reduces time spent on analysis and greatly increases repeatability. Analysis yields numerical measures of vessel volume fraction, vessel length density, fractal dimension (a measure of tortuosity), and radii of murine vascular networks. Because our GUI is open sourced to all, it can be easily modified to measure parameters such as percent coverage of non-endothelial cells, number of loops in a vascular bed, amount of perfusion and two-dimensional branch angle. Importantly, the GUI is compatible with standard fluorescent staining and imaging protocols, but also has utility analyzing brightfield vascular images, obtained, for example, in dorsal skinfold chambers. A manually measured image can be typically completed in 20 minutes to 1 hour. In stark comparison, using our GUI, image analysis time is reduced to around 1 minute. This drastic reduction in analysis time coupled with increased repeatability makes this tool valuable for all vessel research especially those requiring rapid and reproducible results, such as anti-angiogenic drug screening

    Meta-DiSc: a software for meta-analysis of test accuracy data

    Get PDF
    BACKGROUND: Systematic reviews and meta-analyses of test accuracy studies are increasingly being recognised as central in guiding clinical practice. However, there is currently no dedicated and comprehensive software for meta-analysis of diagnostic data. In this article, we present Meta-DiSc, a Windows-based, user-friendly, freely available (for academic use) software that we have developed, piloted, and validated to perform diagnostic meta-analysis. RESULTS: Meta-DiSc a) allows exploration of heterogeneity, with a variety of statistics including chi-square, I-squared and Spearman correlation tests, b) implements meta-regression techniques to explore the relationships between study characteristics and accuracy estimates, c) performs statistical pooling of sensitivities, specificities, likelihood ratios and diagnostic odds ratios using fixed and random effects models, both overall and in subgroups and d) produces high quality figures, including forest plots and summary receiver operating characteristic curves that can be exported for use in manuscripts for publication. All computational algorithms have been validated through comparison with different statistical tools and published meta-analyses. Meta-DiSc has a Graphical User Interface with roll-down menus, dialog boxes, and online help facilities. CONCLUSION: Meta-DiSc is a comprehensive and dedicated test accuracy meta-analysis software. It has already been used and cited in several meta-analyses published in high-ranking journals. The software is publicly available at

    Estimating the Accuracy of Anal Cytology in the Presence of an Imperfect Reference Standard

    Get PDF
    Background: The study aim is to estimate sensitivity and specificity of anal cytology for histologic HSIL in analyses adjusted for the imperfect biopsy reference standard. Methods and Principal Findings: Retrospective cohort study of an anal dysplasia screening program for HIV infected adults. We estimated the prevalence of histologic HSIL by concurrent cytology category and the associated cytology ROC area. Cytology operating characteristics for HSIL were estimated and adjusted for the imperfect reference standard by 3 methodologies. The study cohort included 261 patients with 3 available measures: (1) referral cytology; (2) HRA cytology; and (3) HRA directed biopsy. The prevalence of biopsy HSIL varied according to the concurrent HRA cytology result: 64.5

    Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences

    Get PDF
    To assess the variability and systematic differences in polyp measurements on optical colonoscopy and CT colonography. Gastroenterologists measured 51 polyps by visual estimation, forceps comparison and linear probe. CT colonography observers randomly assessed polyp size two-dimensionally (abdominal and intermediate window) and three-dimensionally (manually and semi-automatically). Linear mixed models were used to assess the variability and systematic differences between CT colonography and optical colonoscopy techniques. The variability of forceps and linear probe measurements was comparable and both showed less variability than measurement by visual assessment. Measurements by linear probe were 0.7 mm smaller than measurements by visual assessment or by forceps. The variability of all CT colonography techniques was lower than for measurements by forceps or visual assessment and sometimes lower (only 2D intermediate window and manual 3D) compared with measurements by linear probe. All CT colonography measurements judged polyps to be larger than optical colonoscopy, with differences ranging from 0.7 to 2.3 mm. A linear probe does not reduce the measurement variability of endoscopists compared with the forceps. Measurement differences between observers on CT colonography were usually smaller than at optical colonoscopy. Polyps appeared larger when using various CT colonography techniques than when measured during optical colonoscop
    corecore