197 research outputs found

    Analysis of bearing wear, whole blood and synovial fluid metal ion concentrations and histopathological findings in patients with failed ASR hip resurfacings

    Get PDF
    Background Adverse Reaction to Metal Debris (ARMD) is still a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. ARMD consists of a wide range of alterations in periprosthetic tissues, most important of which are metallosis, inflammation, pseudotumors and necrosis. Studies investigating histopathological findings and their association to implant wear or indirect measures of wear have yielded inconsistent results. Therefore, we aimed to investigate bearing surface wear volume, whole blood and synovial fluid metal ion concentrations, histopathological findings in periprosthetic tissues and their associations. Methods Seventy-eight patients with 85 hips revised for ARMD were included in the study. Prior to revision surgery, all patients had whole blood chromium and cobalt ion levels assessed. In revision surgery, a synovial fluid sample was taken and analyzed for chromium and cobalt. Periprosthetic tissue samples were taken and analyzed for histopathological findings. Explanted implants were analyzed for bearing wear volume of both acetabular cup and femoral head components. Results Volumetric wear of the failed components was highly variable. The total wear volume of the head and cup had a strong correlation with whole blood chromium and cobalt ion concentrations (Cr: ρ = 0.80, p < 0.001 and Co: ρ = 0.84, p < 0.001) and a bit weaker correlation with fluid chromium and cobalt ion concentrations (Cr: ρ = 0.50, p < 0.01 and Co: ρ = 0.41, p = 0.027). Most tissues displayed only low-to-moderate amounts of macrophages and lymphocytes. Total wear volume correlated with macrophage sheet thickness (ρ = 0.25, p = 0.020) and necrosis (ρ = 0.35, p < 0.01). Whole blood chromium and cobalt ion concentrations had similar correlations. Lymphocyte cuff thickness did not correlate with either total wear volume or whole blood metal ion concentrations, but correlated with the grade of necrosis. Conclusions Bearing wear volume correlated with blood metal ion levels and the degree of necrosis and macrophage infiltration in periprosthetic tissues suggesting a dose-response relationship. Whole blood metal ion levels are a useful tool for clinician to estimate bearing wear and subsequent tissue response

    Scheduled Emergency Trauma Operation : The Green Line Orthopedic Trauma Surgery Process Of Care

    Get PDF
    Background and Aims: Traditionally, patients requiring an orthopedic emergency operation were admitted to an inpatient ward to await surgery. This often led to congestion of wards and operation rooms while, for less urgent traumas, the time spent waiting for the operation often became unacceptably long. The purpose of this study was to evaluate the flow of patients coded green in a traffic light-based coding process aimed at decreasing the burden on wards and enabling a scheduled emergency operation in Central Finland Hospital. Materials and Methods: Operation urgency was divided into three categories: green (>48 h), yellow (8-48 h), and red (Peer reviewe

    Lack of evidence-the anti-stepwise introduction of metal-on-metal hip replacements: A systematic review and a comparative assessment of the literature and registry data

    Get PDF
    Background and purpose - Orthopedics and especially joint replacement surgery have had more than their fair share of unsuccessful innovations that have violated widely endorsed principles for the introduction of new surgical innovations. We aimed to investigate (1) the trends in the use of the Birmingham Hip Resurfacing (BHR), the ASR hip resurfacing (ASR HRA) and the ASR XL total hip replacement (ASR XL THR) system with very different market approval processes and (2) whether their use was corroborated by clinical trials published in the peer-reviewed literature.Methods - The literature was searched for any clinical studies that reported outcomes of the BHR, ASR HRA and ASR XL THRs. Data from 7 national hip arthroplasty registers were collected and the number of annually implanted devices was matched to those reported in the literature.Results - The cumulative number of implanted and published BHRs grew proportionally with a small lag. The growth of implanted BHRs started to decline at the same time as the ASR HR was introduced. With regard to ASR HRAs, the cumulative proportion of implanted hips and those included in the published studies grew disproportionately after the introduction of the ASR in 2003. For ASR XL THRs, the disproportionality is even higher.Interpretation - The adoption of ASR hip replacements did not follow the proposed stepwise introduction of orthopedic implants. The adoption and use of any new implant should follow a strict guideline and algorithm even if the theoretical basis or the results of preclinical studies are excellent

    The MEV project: design and testing of a new high-resolution telescope for Muography of Etna Volcano

    Get PDF
    The MEV project aims at developing a muon telescope expressly designed for the muography of Etna Volcano. In particular, one of the active craters in the summit area of the volcano would be a suitable target for this experiment. A muon tracking telescope with high imaging resolution was built and tested during 2017. The telescope is a tracker based on extruded scintillating bars with WLS fibres and featuring an innovative read-out architecture. It is composed of three XY planes with a sensitive area of \SI{1}{m^2}; the angular resolution does not exceeds \SI{0.4}{\milli\steradian} and the total angular aperture is about ±\pm\SI{45}{\degree}. A special effort concerned the design of mechanics and electronics in order to meet the requirements of a detector capable to work in a hostile environment such as the top of a tall volcano, at a far distance from any facility. The test phase started in January 2017 and ended successfully at the end of July 2017. An extinct volcanic crater (the Monti Rossi, in the village of Nicolosi, about 15km from Catania) is the target of the measurement. The detector acquired data for about 120 days and the preliminary results are reported in this work

    Changes in operative treatment of tibia fractures in Finland between 2000 and 2018: A nationwide study

    Get PDF
    Introduction:Incidences of different tibia fractures are not well reported. Possible changes in the operative treatment methods have also not been studied. The aim of this nationwide registry study is to determine the incidence of operatively treated tibia fractures and investigate the possible changes in treatment methods in Finland between 2000 and 2018.Methods:All patients aged 16 years or older with operatively treated tibia fractures in Finland from 2000 to 2018 were included. The incidence of operatively treated proximal, diaphyseal, and distal tibia fractures per 100,000 person years by age, sex, mechanism of injury, and study year was calculated. Data were extracted from the Finnish National Hospital Discharge Register.Results:A total of 5996 proximal, 6874 diaphyseal, and 5658 distal tibia fractures were reported during the 18-year study period, resulting in incidences of 7.2/100,000, 8.1/100,000, and 6.9/100,000 person years for operatively treated proximal, diaphyseal, and distal tibia fractures, respectively. Over the study period, a clear change in fixation method in distal tibia fractures was found as plating became popular in the beginning of the 21st century. During the last 5 years of the study period, nailing and plating were equally used.Conclusions:Operatively treated proximal tibia fractures are most common among older females while diaphyseal fractures are most frequent in young male patients. Distal tibia fractures occur most often among middle-aged people.</p

    Changes in operative treatment of tibia fractures in Finland between 2000 and 2018 : A nationwide study

    Get PDF
    Introduction: Incidences of different tibia fractures are not well reported. Possible changes in the operative treatment methods have also not been studied. The aim of this nationwide registry study is to determine the incidence of operatively treated tibia fractures and investigate the possible changes in treatment methods in Finland between 2000 and 2018. Methods: All patients aged 16 years or older with operatively treated tibia fractures in Finland from 2000 to 2018 were included. The incidence of operatively treated proximal, diaphyseal, and distal tibia fractures per 100,000 person years by age, sex, mechanism of injury, and study year was calculated. Data were extracted from the Finnish National Hospital Discharge Register. Results: A total of 5996 proximal, 6874 diaphyseal, and 5658 distal tibia fractures were reported during the 18-year study period, resulting in incidences of 7.2/100,000, 8.1/100,000, and 6.9/100,000 person years for operatively treated proximal, diaphyseal, and distal tibia fractures, respectively. Over the study period, a clear change in fixation method in distal tibia fractures was found as plating became popular in the beginning of the 21st century. During the last 5 years of the study period, nailing and plating were equally used. Conclusions: Operatively treated proximal tibia fractures are most common among older females while diaphyseal fractures are most frequent in young male patients. Distal tibia fractures occur most often among middle-aged people.publishedVersionPeer reviewe

    Repeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement

    Get PDF
    Background and purpose - Whole blood (WB) cobalt (Co) and chromium (Cr) ion levels have a major role in the follow-up of metal-on-metal total hip replacement (MoM THR). We investigated, first, if there was a change in WB Co or Cr levels over repeated measurements in patients with ReCap-M2A-Magnum THR, and, second, determined how many patients had WB Co or Cr levels that exceeded the safe upper limits (SUL) in the repeated whole blood metal ion assessment. Patients and methods - A Recap-M2A-Magnum THR was used in 1,329 operations (1,188 patients) at our institution between 2005 and 2012. We identified all patients (n = 319) with unilateral ReCap-M2A-Magnum implants who had undergone at least 2 repeated metal ion measurements with the first blood sample taken mean 5.5 years (1.8-9.3) after surgery and the second taken mean 2 years (0.5-3) after the first. Results - The median WB Co and Cr ion levels decreased in repeated measurements from 1.40 (0.40-63) ppb to 1.10 (0.20-68) ppb and from 1.60 (0.60-13.0) ppb to 1.10 (0.30-19.0) ppb, respectively. 7% of the Co ion values exceeded SUL at the initial measurement, and 7% at the control measurement. The proportion of Cr ion values exceeding the safe upper limit (SUL) decreased during the measurement interval from 5% to 4%. Interpretation - Repeated metal ion measurements in unilateral ReCap-M2A-Magnum patients in a mean 2-year time interval did not show any increase. Long-term ion levels are, however, not yet known

    Host-specific factors affect the pathogenesis of adverse reaction to metal debris

    Get PDF
    BACKGROUND: Adverse Reaction to Metal Debris (ARMD) is a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. Most failures are related to excessively wearing implant producing harmful metal debris (extrinsic factor). As ARMD may also occur in patients with low-wearing implants, it has been suggested that there are differences in host-specific intrinsic factors contributing to the development of ARMD. However, there are no studies that have directly assessed whether the development of ARMD is actually affected by these intrinsic factors. METHODS: We included all 29 patients (out of 33 patients) with sufficient data who had undergone bilateral revision of ASR MoM hips (58 hips) at our institution. Samples of the inflamed synovia and/or pseudotumour were obtained perioperatively and sent to histopathological analysis. Total wear volumes of the implants were assessed. Patients underwent MARS-MRI imaging of the hips preoperatively. Histological findings, imaging findings and total wear volumes between the hips of each patient were compared. RESULTS: The difference in wear volume between the hips was clinically and statistically significant (median difference 15.35 mm^{3}, range 1 to 39 mm^{3}, IQR 6 to 23 mm^{3}) (p  0.05 for all comparisons). These features included macrophage sheet thickness, perivascular lymphocyte cuff thickness, presence of plasma cells, presence of diffuse lymphocytic infiltration and presence of germinal centers. CONCLUSIONS: Despite the significantly differing amounts of wear (extrinsic factor) seen between the sides, majority of the histological findings were similar in both hips and the presence of pseudotumour was symmetrical in most hips. As a direct consequence, it follows that there must be intrinsic factors which contribute to the symmetry of the findings, ie. the pathogenesis of ARMD, on individual level. This has been hypothesized in the literature but no studies have been conducted to confirm the hypothesis. Further, as the threshold of metal debris needed to develop ARMD appears to be largely variable based on the previous literature, it is likely that there are between-patient differences in these intrinsic factors, ie. the host response to metal debris is individual

    Smoking is a predictor of complications in all types of surgery : a machine learning-based big data study

    Get PDF
    Background: Machine learning algorithms are promising tools for smoking status classification in big patient data sets. Smoking is a risk factor for postoperative complications in major surgery. Whether this applies to all surgery is unknown. The aims of this retrospective cohort study were to develop a machine learning algorithm for clinical record-based smoking status classification and to determine whether smoking and former smoking predict complications in all surgery types. Methods: All surgeries performed in a Finnish hospital district from 1 January 2015 to 31 December 2019 were analysed. Exclusion criteria were age below 16 years, unknown smoking status, and unknown ASA class. A machine learning algorithm was developed for smoking status classification. The primary outcome was 90-day overall postoperative complications in all surgeries. Secondary outcomes were 90-day overall complications in specialties with over 10 000 surgeries and critical complications in all surgeries. Results: The machine learning algorithm had precisions of 0.958 for current smokers, 0.974 for ex-smokers, and 0.95 for never-smokers. The sample included 158 638 surgeries. In adjusted logistic regression analyses, smokers had increased odds of overall complications (odds ratio 1.17; 95 per cent c.i. 1.14 to 1.20) and critical complications (odds ratio 1.21; 95 per cent c.i. 1.14 to 1.29). Corresponding odds ratios of ex-smokers were 1.09 (95 per cent c.i. 1.06 to 1.13) and 1.09 (95 per cent c.i. 1.02 to 1.17). Smokers had increased odds of overall complications in all specialties with over 10 000 surgeries. ASA class was the most important complication predictor. Conclusion: Machine learning algorithms are feasible for smoking status classification in big surgical data sets. Current and former smoking predict complications in all surgery types.Peer reviewe
    corecore