165 research outputs found

    Thermal Performance Expectations of the Advanced Stirling Convertor Over a Range of Operating Scenarios

    Get PDF
    The Advanced Stirling Radioisotope Generator (ASRG) will enable various missions such as small body sample return, atmospheric missions around Venus, as well as long - duration deep space missions. Analysis of the temperature distributions are performed on an Advanced Stirling Convertor, and the results are compared with available experimental measurements. This analysis includes applied environmental conditions that are similar to those that will be experienced while the convertor is in operation. The applied conditions represent a potential mission profile including pre-takeoff sterilization, launch, transit, and return. The results focus on the anticipated peak temperatures of the magnets in the linear alternator. These results confirm that the ASC can support future missions to deep space targets, extreme environment landers, as well as more conventional goals

    Two-Step Multi-Physics Analysis of an Annular Linear Induction Pump for Fission Power Systems

    Get PDF
    One of the key technologies associated with fission power systems (FPS) is the annular linear induction pump (ALIP). ALIPs are used to circulate liquid-metal fluid for transporting thermal energy from the nuclear reactor to the power conversion device. ALIPs designed and built to date for FPS project applications have not performed up to expectations. A unique, two-step approach was taken toward the multi-physics examination of an ALIP using ANSYS Maxwell 3D and Fluent. This multi-physics approach was developed so that engineers could investigate design variations that might improve pump performance. Of interest was to determine if simple geometric modifications could be made to the ALIP components with the goal of increasing the Lorentz forces acting on the liquid-metal fluid, which in turn would increase pumping capacity. The multi-physics model first calculates the Lorentz forces acting on the liquid metal fluid in the ALIP annulus. These forces are then used in a computational fluid dynamics simulation as (a) internal boundary conditions and (b) source functions in the momentum equations within the Navier-Stokes equations. The end result of the two-step analysis is a predicted pump pressure rise that can be compared with experimental data

    Overview of Heat Addition and Efficiency Predictions for an Advanced Stirling Convertor

    Get PDF
    The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. Microporous bulk insulation is used in the ground support test hardware to minimize the loss of thermal energy from the electric heat source to the environment. The insulation package is characterized before operation to predict how much heat will be absorbed by the convertor and how much will be lost to the environment during operation. In an effort to validate these predictions, numerous tasks have been performed, which provided a more accurate value for net heat input into the ASCs. This test and modeling effort included: (a) making thermophysical property measurements of test setup materials to provide inputs to the numerical models, (b) acquiring additional test data that was collected during convertor tests to provide numerical models with temperature profiles of the test setup via thermocouple and infrared measurements, (c) using multidimensional numerical models (computational fluid dynamics code) to predict net heat input of an operating convertor, and (d) using validation test hardware to provide direct comparison of numerical results and validate the multidimensional numerical models used to predict convertor net heat input. This effort produced high fidelity ASC net heat input predictions, which were successfully validated using specially designed test hardware enabling measurement of heat transferred through a simulated Stirling cycle. The overall effort and results are discussed

    NASA Low Power Stirling Convertor for Small Landers, Probes, and Rovers Operating in Darkness

    Get PDF
    A variety of mission concepts have been studied by NASA and the U. S. Department of Energy that would utilize low power Radioisotope Power Systems (RPS) for probes, landers rovers, and repeaters. These missions would contain science instruments distributed across planetary surfaces or near objects of interest where solar flux is insufficient for using solar cells. Landers could be used to provide data like radiation, temperature, pressure, seismic activity, and other surface measurements for planetary science and to inform future mission planners. The studies proposed using fractional versions of the General Purpose Heat Source (GPHS) or multiple Light Weight Radioisotope Heater Units (LWRHU) to heat power conversion technologies for science instruments and communication. Dynamic power systems are capable of higher conversion efficiencies, which could enable equal power using less fuel or more power using equal fuel, when compared to less efficient static power conversion technologies. Providing spacecraft with more power would decrease duty cycling of basic functions and, therefore, increase the quality and abundance of science data. Low power Stirling convertors are being developed at NASA Glenn Research Center (GRC) to provide future micro spacecraft with electrical power by converting heat from one or more LWRHUs. An initial design converts multiple watts of heat to one watt of electrical power output using a Stirling convertor. Development of the concept includes maturation of convertor and controller designs, performance evaluation of an evacuated metal foil insulation, and development of system interfaces. Demonstration of the convertor is planned and represents a new class of RPS with power levels an order of magnitude lower than previous practical designs

    The Chromospheric Activity and Ages of M Dwarf Stars in Wide Binary Systems

    Get PDF
    We investigate the relationship between age and chromospheric activity for 139 M dwarf stars in wide binary systems with white dwarf companions. The age of each system is determined from the cooling age of its white dwarf component. The current limit for activity-age relations found for M dwarfs in open clusters is 4 Gyr. Our unique approach to finding ages for M stars allows for the exploration of this relationship at ages older than 4 Gyr. The general trend of stars remaining active for a longer time at later spectral type is confirmed. However, our larger sample and greater age range reveals additional complexity in assigning age based on activity alone. We find that M dwarfs in wide binaries older than 4 Gyr depart from the log-linear relation for clusters and are found to have activity at magnitudes, colors and masses which are brighter, bluer and more massive than predicted by the cluster relation. In addition to our activity-age results, we present the measured radial velocities and complete space motions for 161 white dwarf stars in wide binaries.Comment: 22 pages including 9 figures and 5 tables. Accepted for publication in The Astronomical Journa

    NASA Low-Power Stirling Convertor for Small Landers, Probes, and Rovers Operating in Darkness

    Get PDF
    A variety of mission concepts have been studied by NASA and the U. S. Department of Energy that would utilize low power Radioisotope Power Systems (RPS) for landers, probes, and rovers. These missions would contain science measuring instruments distributed across planetary surfaces or near objects of interest where solar flux is insufficient for using solar cells. Landers could be used to provide data like wind, temperature, pressure, seismic activity, and other planetary measurements to mission planners or future explorers. The studies proposed using fractional versions of the General Purpose Heat Source (GPHS) or multiple Light Weight Radioisotope Heater Units (LWRHU) to heat power conversion technologies for science instruments and communication. Dynamic power systems are capable of higher conversion efficiencies, which could enable equal power using less fuel or more power using equal fuel, when compared to less efficient static power conversion technologies. Providing spacecraft with more power would decrease duty cycling of basic functions and, therefore, increase the quality and abundance of science data. Low power Stirling convertors are being developed at NASA Glenn Research Center (GRC) to provide future micro spacecraft with electrical power by converting heat from one or more LWRHUs. An initial design converts multiple Watts of heat to one Watt of electrical power output using a Stirling convertor. Development of the concept includes maturation of convertor and controller designs, performance evaluation of an evacuated metal foil insulation, and development of system interfaces

    A Computational Methodology for Simulating Thermal Loss Testing of the Advanced Stirling Convertor

    Get PDF
    Convertor and generator testing is carried out in tests designed to characterize convertor performance when subjected to environments intended to simulate launch and space conditions. The value of net heat input must be known in order to calculate convertor efficiency and to validate convertor performance. Specially designed test hardware was used to verify and validate a two step methodology for the prediction of net heat input. This lessons learned from these simulations have been applied to previous convertor simulations. As heat is supplied to the convertors, electric power is produced and measured. Net heat input to the convertor is one parameter that will contribute to the calculation of efficiency. This parameter is not measured directly. Insulation Loss. Determine the current status of the thermal conductivity of the micro-porous insulation. - Match heat source and hot end temperatures. - Match temperature difference across Kaowool insulatio

    Effect of exercise therapy on lipid profile and oxidative stress indicators in patients with type 2 diabetes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Yoga has been shown to be a simple and economical therapeutic modality that may be considered as a beneficial adjuvant for type 2 diabetes mellitus. This study investigated the impact of Hatha yoga and conventional physical training (PT) exercise regimens on biochemical, oxidative stress indicators and oxidant status in patients with type 2 diabetes.</p> <p>Methods</p> <p>This prospective randomized study consisted of 77 type 2 diabetic patients in the Hatha yoga exercise group that were matched with a similar number of type 2 diabetic patients in the conventional PT exercise and control groups. Biochemical parameters such as fasting blood glucose (FBG), serum total cholesterol (TC), triglycerides, low-density lipoprotein (LDL), very low-density lipoproteins (VLDL) and high-density lipoprotein (HDL) were determined at baseline and at two consecutive three monthly intervals. The oxidative stress indicators (malondialdehyde – MDA, protein oxidation – POX, phospholipase A2 – PLA2 activity) and oxidative status [superoxide dismutase (SOD) and catalase activities] were measured.</p> <p>Results</p> <p>The concentrations of FBG in the Hatha yoga and conventional PT exercise groups after six months decreased by 29.48% and 27.43% respectively (P < 0.0001) and there was a significant reduction in serum TC in both groups (P < 0.0001). The concentrations of VLDL in the managed groups after six months differed significantly from baseline values (P = 0.036). Lipid peroxidation as indicated by MDA significantly decreased by 19.9% and 18.1% in the Hatha yoga and conventional PT exercise groups respectively (P < 0.0001); whilst the activity of SOD significantly increased by 24.08% and 20.18% respectively (P = 0.031). There was no significant difference in the baseline and 6 months activities of PLA2 and catalase after six months although the latter increased by 13.68% and 13.19% in the Hatha yoga and conventional PT exercise groups respectively (P = 0.144).</p> <p>Conclusion</p> <p>The study demonstrate the efficacy of Hatha yoga exercise on fasting blood glucose, lipid profile, oxidative stress markers and antioxidant status in patients with type 2 diabetes and suggest that Hatha yoga exercise and conventional PT exercise may have therapeutic preventative and protective effects on diabetes mellitus by decreasing oxidative stress and improving antioxidant status.</p> <p>Trial Registration</p> <p>Australian New Zealand Clinical Trials Registry (ANZCTR): ACTRN12608000217303</p