20 research outputs found

    Assessment of Electronic Health Information System Use and Need in US Adult Congenital Heart Disease Centersc hd_498 134..138

    Get PDF
    A B S T R A C T Objectives. Efforts to improve care for adult congenital heart disease (ACHD) patients necessitates collection of accurate, detailed, longitudinal data. We sought to document what electronic health record systems are currently available at ACHD centers and to assess national interest in a uniform ACHD-focused system. Design. Directors of ACHD centers in the United States were invited to complete an online questionnaire regarding current health information systems at their institution both for general cardiology and for ACHD. Topics that were surveyed included utility and perceived limitations of currently available systems. The survey also assessed the level of interest in an ACHD-specific system, and its optimal functions. Results. Thirty-four centers responded, representing both pediatric and adult institutions that care for patients with ACHD. Of these, 80% reported using a variety of commercially supported electronic medical record products, whereas only 50% employed an ACHD-specific noncommercial database to supplement their institutional system. Comparison of the two systems revealed that most clinical activities are pursued through the institutional electronic medical record system. Research and tracking of clinical activities were the primary uses of ACHD-specific systems, which have several noted limitations. Strong interest in an integrated ACHD-specific system was found among responders. Conclusions. There is both an unmet need and a strong interest in an ACHD-oriented electronic health record that could facilitate research, outcome tracking, quality assurance, and inter-institutional collaboration, all functions that are lacking in electronic health systems currently in use

    Ionizing radiation doses during lower limb torsion and anteversion measurements by EOS stereoradiography and computed tomography

    No full text
    International audienceObjectives To calculate and compare the doses of ionizing radiation delivered to the organs by computed tomography (CT) and stereoradiography (SR) during measurements of lower limb torsion and anteversion. Materials and methods A Rando anthropomorphic phantom (Alderson RANDO phantom, Alderson Research Laboratories Inc., Stanford, Conn) was used for the dose measurements. The doses were delivered by a Somatom 16-slice CT-scanner (Siemens, Erlangen) and an EOS stereoradiography unit (EOS-Imaging, Paris) according to the manufacturers' acquisition protocols. Doses to the surface and deeper layers were calculated with thermoluminiscent GR207P dosimeters. Dose uncertainties were evaluated and assessed at 6% at k = 2 (that is, two standard deviations). Results The absorbed doses for the principal organs assessed were as follows for the ovaries, 0.1 mGy to the right ovary and 0.5 mGy to the left ovary with SR versus1.3 mGy and 1.1 mGy with CT, respectively; testes, 0.3 mGy on the right and 0.4 mGy on the left with SR versus 8.5 mGy and 8.4 mGy with CT; knees, 0.4 mGy to the right knee and 0.8 mGy to the left knee with SR versus 11 mGy and 10.4 mGy with CT; ankles, 0.5 mGy to the right ankle and 0.8 mGy to the left with SR versus 15 mGy with CT. Conclusion The SR system delivered substantially lower doses of ionizing radiation doses than CT to all the organs studied CT doses were 4.1 times higher to the ovaries, 24 times higher for the testicles, and 13-30 times higher for the knees and ankles. The use of the SR system to study the torsion of lower limbs makes it possible to reduce the amount of medical irradiation that patients accumulate. © 2013 Elsevier Ireland Ltd

    Predicted cancer risks induced by computed tomography examinations during childhood, by a quantitative risk assessment approach

    No full text
    International audienceThe potential adverse effects associated with exposure to ionizing radiation from computed tomography (CT) in pediatrics must be characterized in relation to their expected clinical benefits. Additional epidemiological data are, however, still awaited for providing a lifelong overview of potential cancer risks. This paper gives predictions of potential lifetime risks of cancer incidence that would be induced by CT examinations during childhood in French routine practices in pediatrics. Organ doses were estimated from standard radiological protocols in 15 hospitals. Excess risks of leukemia, brain/central nervous system, breast and thyroid cancers were predicted from dose-response models estimated in the Japanese atomic bomb survivors' dataset and studies of medical exposures. Uncertainty in predictions was quantified using Monte Carlo simulations. This approach predicts that 100,000 skull/brain scans in 5-year-old children would result in eight (90 % uncertainty interval (UI) 1-55) brain/CNS cancers and four (90 % UI 1-14) cases of leukemia and that 100,000 chest scans would lead to 31 (90 % UI 9-101) thyroid cancers, 55 (90 % UI 20-158) breast cancers, and one (90 % UI <0.1-4) leukemia case (all in excess of risks without exposure). Compared to background risks, radiation-induced risks would be low for individuals throughout life, but relative risks would be highest in the first decades of life. Heterogeneity in the radiological protocols across the hospitals implies that 5-10 % of CT examinations would be related to risks 1.4-3.6 times higher than those for the median doses. Overall excess relative risks in exposed populations would be 1-10 % depending on the site of cancer and the duration of follow-up. The results emphasize the potential risks of cancer specifically from standard CT examinations in pediatrics and underline the necessity of optimization of radiological protocols. © 2013 Springer-Verlag Berlin Heidelberg

    Radiation exposure from CT in early childhood A French large-scale multicentre study

    No full text
    International audienceObjectives The increasing use of CT scans in the paediatric population raises the question of a possible health impact of ionising radiation exposure associated with CT scans. The aim of this study was to describe the pattern of CT use in early childhood. Methods In 14 major French paediatric radiology departments, children undergoing at least 1 CT scan before age 5, between 2000 and 2006, were included. For each examination, absorbed organ doses were calculated. Results 43% of the 27 362 children in the cohort were aged less than 1 year during their first exposure, with 9% being aged less than 1 month. The mean number of examinations per child was 1.6 (range 1-43). The examinations included head in 63% of the cases, chest in 21%, abdomen and pelvis in 8% and others in 8%. Brain and eye lenses received the highest cumulative doses from head examinations, with mean organ dose values of 22 mGy (maximum 1107 mGy) and 26 mGy (maximum 1392 mGy), respectively. The mean cumulative effective dose was 3.2 mSv (range 0.1-189 mSv). Conclusion CT scan exposure in childhood is responsible for relatively high doses to radiosensitive organs. The rather large dose range according to the protocols used requires their optimisation. The cohort follow-up will study the risk of long-term radiation-induced cancer. © 2012 The British Institute of Radiology

    Are the studies on cancer risk from CT scans biased by indication? Elements of answer from a large-scale cohort study in France

    No full text
    International audienceBackground Recent epidemiological results suggested an increase of cancer risk after receiving computed tomography (CT) scans in childhood or adolescence. Their interpretation is questioned due to the lack of information about the reasons for examination. Our objective was to estimate the cancer risk related to childhood CT scans, and examine how cancer-predisposing factors (PFs) affect assessment of the radiation-related risk. Methods The cohort included 67 274 children who had a first scan before the age of 10 years from 2000 to 2010 in 23 French departments. Cumulative X-rays doses were estimated from radiology protocols. Cancer incidence was retrieved through the national registry of childhood cancers; PF from discharge diagnoses. Results During a mean follow-up of 4 years, 27 cases of tumours of the central nervous system, 25 of leukaemia and 21 of lymphoma were diagnosed; 32% of them among children with PF. Specific patterns of CT exposures were observed according to PFs. Adjustment for PF reduced the excess risk estimates related to cumulative doses from CT scans. No significant excess risk was observed in relation to CT exposures. Conclusions This study suggests that the indication for examinations, whether suspected cancer or PF management, should be considered to avoid overestimation of the cancer risks associated with CT scans. © 2015 Cancer Research UK
    corecore