30 research outputs found

    Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research

    Get PDF
    AIMS The Valve Academic Research Consortium (VARC), founded in 2010, was intended to (i) identify appropriate clinical endpoints and (ii) standardize definitions of these endpoints for transcatheter and surgical aortic valve clinical trials. Rapid evolution of the field, including the emergence of new complications, expanding clinical indications, and novel therapy strategies have mandated further refinement and expansion of these definitions to ensure clinical relevance. This document provides an update of the most appropriate clinical endpoint definitions to be used in the conduct of transcatheter and surgical aortic valve clinical research.METHODS AND RESULTS Several years after the publication of the VARC-2 manuscript, an in-person meeting was held involving over 50 independent clinical experts representing several professional societies, academic research organizations, the US Food and Drug Administration (FDA), and industry representatives to (i) evaluate utilization of VARC endpoint definitions in clinical research, (ii) discuss the scope of this focused update, and (iii) review and revise specific clinical endpoint definitions. A writing committee of independent experts was convened and subsequently met to further address outstanding issues. There were ongoing discussions with FDA and many experts to develop a new classification schema for bioprosthetic valve dysfunction and failure. Overall, this multi-disciplinary process has resulted in important recommendations for data reporting, clinical research methods, and updated endpoint definitions. New definitions or modifications of existing & nbsp;definitions are being proposed for repeat hospitalizations, access site-related complications, bleeding events, conduction disturbances, cardiac structural complications, and bioprosthetic valve dysfunction and failure (including valve leaflet thickening and thrombosis). A more granular 5-class grading scheme for paravalvular regurgitation (PVR) is being proposed to help refine the assessment of PVR. Finally, more specific recommendations on quality-of-life assessments have been included, which have been targeted to specific clinical study designs.CONCLUSIONS Acknowledging the dynamic and evolving nature of less-invasive aortic valve therapies, further refinements of clinical research processes are required. The adoption of these updated and newly proposed VARC-3 endpoints and definitions will ensure homogenous event reporting, accurate adjudication, and appropriate comparisons of clinical research studies involving devices and new therapeutic strategies.Cardiolog

    Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research

    Get PDF
    Aims The Valve Academic Research Consortium (VARC), founded in 2010, was intended to (i) identify appropriate clinical endpoints and (ii) standardize definitions of these endpoints for transcatheter and surgical aortic valve clinical trials. Rapid evolution of the field, including the emergence of new complications, expanding clinical indications, and novel therapy strategies have mandated further refinement and expansion of these definitions to ensure clinical relevance. This document provides an update of the most appropriate clinical endpoint definitions to be used in the conduct of transcatheter and surgical aortic valve clinical research.Methods and results Several years after the publication of the VARC-2 manuscript, an in-person meeting was held involving over 50 independent clinical experts representing several professional societies, academic research organizations, the US Food and Drug Administration (FDA), and industry representatives to (i) evaluate utilization of VARC endpoint definitions in clinical research, (ii) discuss the scope of this focused update, and (iii) review and revise specific clinical endpoint definitions. A writing committee of independent experts was convened and subsequently met to further address outstanding issues. There were ongoing discussions with FDA and many experts to develop a new classification schema for bioprosthetic valve dysfunction and failure. Overall, this multi-disciplinary process has resulted in important recommendations for data reporting, clinical research methods, and updated endpoint definitions. New definitions or modifications of existing definitions are being proposed for repeat hospitalizations, access site-related complications, bleeding events, conduction disturbances, cardiac structural complications, and bioprosthetic valve dysfunction and failure (including valve leaflet thickening and thrombosis). A more granular 5-class grading scheme for paravalvular regurgitation (PVR) is being proposed to help refine the assessment of PVR. Finally, more specific recommendations on quality-of-life assessments have been included, which have been targeted to specific clinical study designs.Conclusions Acknowledging the dynamic and evolving nature of less-invasive aortic valve therapies, further refinements of clinical research processes are required. The adoption of these updated and newly proposed VARC-3 endpoints and definitions will ensure homogenous event reporting, accurate adjudication, and appropriate comparisons of clinical research studies involving devices and new therapeutic strategies.Cardiolog

    Is heart rate variability related to gait impairment in patients with Parkinson's disease? A pilot study.

    No full text
    Contains fulltext : 80070.pdf (publisher's version ) (Closed access)BACKGROUND AND PURPOSE: Impairments in gait and autonomic function are common in patients with Parkinson's disease (PD). These are likely independent symptoms, based on different etiologic mechanisms. However, a few recent reports have observed an association between motor function, in particular gait impairment, and autonomic function in PD. In those studies, the Unified Parkinson's Disease Rating Scale (UPDRS) was used to evaluate gait and motor function. The present study was performed to further examine this putative relationship using quantitative measures of autonomic function and gait in order to shed light on the underlying pathophysiology of these symptoms. METHODS: Nine healthy young, 15 healthy elderly and 18 PD patients were studied. Heart rate variability (HRV) measures were collected during rest. Gait speed, swing time and swing time variability were measured during a 1-min walk at comfortable speed. The motor portion of the UPDRS was also evaluated in all subjects. RESULTS: HRV values were highest in the young adults, intermediate in the healthy elderly controls, and lowest in the PD patients. Gait measures tended to deteriorate with age and were significantly worse in the PD patients, compared to the elderly controls. HRV was not correlated with any measure of gait performance (p>0.129) nor with the UPDRS-motor score (p>0.147). DISCUSSION AND CONCLUSIONS: The present findings support the idea that gait and autonomic function impairments co-exist in PD, but their etiology is based on distinct pathophysiological pathways, with minimal overlap

    Research principles for developing country food value chains

    No full text
    Item does not contain fulltextFood value chains (FVCs) comprise all activities required to bring farm products to consumers, including agricultural production, processing, storage, marketing, distribution, and consumption. FVCs are changing rapidly in developing countries (DCs), because of population and income growth; urbanization; and the expansion, globally and domestically, of modern food retailing, distribution, and wholesaling firms (1, 2). One such change is that consumers and regulators increasingly demand product-specific characteristics beyond price—including nutrient content; food safety certification; and indicators of impacts on natural resources, greenhouse gas emissions, and farmworkers. To accommodate these multidimensional demands, regulators and firms are developing new multiattribute product labeling and production standards. We outline below ways in which scientists must integrate existing disciplinary evidence into rigorous models and must develop measures and methods to evaluate the multidimensional performance of FVCs.2 p