1,147 research outputs found

    State of the body in disorders of diurnal physiological rhythms and long-term hypokinesia

    Get PDF
    In order to study the effects of hypokinesia and circadian rhythm restructuring on the morphological and functional status of the hypothalamo-hypophysic-adrenal system, young male Wistar rats were placed in small cages for varying periods. The animals were decapitated and preparations were made from sections of the brain and adrenals and numerous destructive changes were noted in the investigated regions of the brain, indicating that the condition of these areas is directly affected by disruption of established rhythms in physiological processes

    Wire GEM detector

    Full text link
    A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by perforation the plastic plate metalized on both sides the WGEM does not suffer from breakdowns between its electrodes and the effect of accumulation of charges on holes walls is absent. As a result the WGEM has high reliability and stability.Comment: Presented at the RD51 Collaboration Meeting, CERN, November 2009, submitted to the Prib. Tech. Expe

    RETGEM with polyvinylchloride (PVC) electrodes

    Full text link
    This paper presents a new design of the RETGEM (Resistive Electrode Thick GEM) based on electrodes made of a polyvinylchloride material (PVC). Our device can operate with gains of 10E5 as a conventional TGEM at low counting rates and as RPC in the case of high counting rates without of the transit to the violent sparks. The distinct feature of present RETGEM is the absent of the metal coating and lithographic technology for manufacturing of the protective dielectric rms. The electrodes from PVC permit to do the holes by a simple drilling machine. Detectors on a RETGEM basis could be useful in many fields of an application requiring a more cheap manufacturing and safe operation, for example, in a large neutrino experiments, in TPC, RICH systems.Comment: Presented at the RD51 Collaboration Meeting, CERN, November 200

    Formation of Multicharged Ions at Quasi-Gasdynamic Plasma Confinement in a Mirror trap

    Get PDF
    It was shown in [1] that an increase in plasma density Ne in sources of multicharged ions leads to a substantial increase of ion current and improves slightly the ion distribution over charge states. Validity of this statement was verified in experiments with plasma densities not exceeding several units of 1012 cm-3. It was revealed [2] that, for the electron densities exceeding 1013 cm-3, the regime of plasma confinement in a trap changes significantly, the scaling described in [1] is no longer valid, and the quasi-gasdynamic regime of plasma confinement is realized. The plasma confinement time ti in this regime weakly depends on electron density. Consequently, the parameter governing formation of multicharged ions, Neti , grows as the electron density is increased. This means that an increase in plasma density results not only in an increase in the total ion current but also in the shift of the ion charge state distribution towards higher charge states. The present work concerns experimental investigation of the quasi-gasdynamic regime of confinement of a hot plasma in a direct magnetic trap and formation of multicharged ions in this regime. Experiments were conducted on the setup described in detail in [3]. Millimeter wave radiation with maximum power W=130 kW, frequency f=37.5 GHz, and pulse duration up to 1.5 ms was focused along magnetic field lines into a simple mirror trap with mirror ratio 3.4, length 25 cm, and maximum magnetic field 2.5 T. The temperature and density of the electrons were determined from spectral analysis of X-ray bremsstrahlung of plasma in the 2-20 keV range and from the transmission factor of diag-nostic microwave radiation through the plasma. It is concluded that a quasi-gasdynamic regime of plasma confinement is realized. Ion distribution over charge states in the quasi-gasdynamic regime is calculated and the re-sults obtained are compared with experimental data. A strong effect of anisotropy of the electron distribution function over energies on the efficiency of plasma confinement and formation of multicharged ions is considered. Problems of plasma stability in an axisymmetric mirror trap un-der powerful microwave pumping are addressed

    Radio Emission and Particle Acceleration in SN 1993J

    Get PDF
    The radio light curves of SN 1993J are found to be well fit by a synchrotron spectrum, suppressed by external free-free absorption and synchrotron self-absorption. A standard r^-2 circumstellar medium is assumed, and found to be adequate. The magnetic field and number density of relativistic electrons behind the shock are determined. The strength of the magnetic field argues strongly for turbulent amplification behind the shock. The ratio of the magnetic and thermal energy density behind the shock is ~0.14. Synchrotron and Coulomb cooling dominate the losses of the electrons. The injected electron spectrum has a power law index -2.1, consistent with diffusive shock acceleration, and the number density scales with the thermal electron energy density. The total energy density of the relativistic electrons is, if extrapolated to gamma ~ 1, ~ 5x10^-4 of the thermal energy density. The free-free absorption required is consistent with previous calculations of the circumstellar temperature of SN 1993J, T_e ~ (2-10)x10^5 K. The relative importance of free-free absorption, Razin suppression, and the synchrotron self-absorption effect for other supernovae are briefly discussed. Guidelines for the modeling and interpretation of VLBI observations are given.Comment: accepted for Ap.

    RPC with low-resistive phosphate glass electrodes as a candidate for the CBM TOF

    Get PDF
    Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes made of phosphate glass, which has bulk resistivity in the order of 10^10 Ohm cm, has been studied with MIP beam for TOF applications. The tests have yielded satisfactory results: the efficiency remains above 95% and the time resolution stays within 120 ps up to the particle rate of 18 kHz/cm2. The increase in rate from 2.25 to 18 kHz/cm2 leads to an increase of estimated "tails" fraction in the time spectrum from 1.5% to 4%.Comment: 8 pages, 6 figures, submitted to Elsevier Scienc

    Semi-Hard Scattering Unraveled from Collective Dynamics by Two-Pion Azimuthal Correlations in 158 A GeV/c Pb + Au Collisions

    Full text link
    Elliptic flow and two-particle azimuthal correlations of charged hadrons and high-pTp_T pions (pT>p_T> 1 GeV/cc) have been measured close to mid-rapidity in 158A GeV/cc Pb+Au collisions by the CERES experiment. Elliptic flow (v2v_2) rises linearly with pTp_T to a value of about 10% at 2 GeV/cc. Beyond pTp_T\approx 1.5 GeV/cc, the slope decreases considerably, possibly indicating a saturation of v2v_2 at high pTp_T. Two-pion azimuthal anisotropies for pT>p_T> 1.2 GeV/cc exceed the elliptic flow values by about 60% in mid-central collisions. These non-flow contributions are attributed to near-side and back-to-back jet-like correlations, the latter exhibiting centrality dependent broadening.Comment: Submitted to Phys. Rev. Letters, 4 pages, 5 figure

    Low-mass e+e- pair production in 158 A GeV Pb-Au collisions at the CERN SPS, its dependence on multiplicity and transverse momentum

    Full text link
    We report a measurement of low-mass electron pairs observed in 158 GeV/nucleon Pb-Au collisions. The pair yield integrated over the range of invariant masses 0.2 < m < 2.0 GeV is enhanced by a factor of 3.5 +/- 0.4 (stat) +/- 0.9 (syst) over the expectation from neutral meson decays. As observed previously in S-Au collisions, the enhancement is most pronounced in the invariant-mass region 300-700 MeV. For Pb-Au we find evidence for a strong increase of the enhancement with centrality. In addition, we show that the enhancement covers a wide range in transverse momentum, but is largest at the lowest observed pt.Comment: 17 pages, 4 figures, submitted to Phys.Lett.

    Recent results from Pb-Au collisions at 158 GeV/c per nucleon obtained with the CERES spectrometer

    Full text link
    During the 1996 lead run time, CERES has accumulated 42 million events, corresponding to a factor of 5 more statistics than in 1995 and 2.5 million events of a special photon-run. We report on the results of the low-mass e+^+e^--pair analysis. Since the most critical item is the poor signal-to-background ratio we also discuss the understanding of this background, in absolute terms, with the help of a detailed Monte Carlo simulation. We show preliminary results of the photon analysis and summarize the results of the hadron analysis preliminarily reported on already at QM'97Comment: 10 pages, 9 figures, Proceedings of the XIV Int. Conf. on Nucleus-Nucleus Collisions,Quark Matter 99, Torino, Italy, May 10 - 15, 199
    corecore