102 research outputs found

    You swallowed what?

    Get PDF

    Chief Complaint: Ingested Button Battery

    Get PDF

    Calibration of Pasture Forage Mass to Plate Meter Compressed Height is a Second-order Response with a Zero Intercept

    Get PDF
    Discusses how plant canopy structure effects the calibration between plate meter compressed height (CHt) and pasture forage mas

    Initial United States experience with the Paracor HeartNet⁎⁎Paracor Medical, Inc, Sunnyvale, Calif. myocardial constraint device for heart failure

    Get PDF
    ObjectiveThis study was undertaken to review the initial results and surgical safety data for the US Food and Drug Administration safety and feasibility trial of the Paracor HeartNet (Paracor Medical, Inc, Sunnyvale, Calif.) myocardial constraint device.MethodsPatients with New York Heart Association functional class II or III heart failure underwent device implantation (n = 21) through a left minithoracotomy.ResultsThe average age was 53 years (31–72 years). There were 18 men and 3 women, and 17 patients had nonischemic etiology of heart failure. Mean heart failure duration was 8.3 years (1.4-18.8 years). Average ejection fraction was 22% (11%-33%), with an average left ventricular end-diastolic dimension of 74 mm (55-94 mm). Previous medical therapy included angiotensin-converting enzyme inhibitors, Ξ²-blockers, diuretics, digoxin, and aldosterone receptor blockers. At implantation, 17 patients had implantable electronic devices: 1 biventricular pacemaker, 11 biventricular pacemakers with cardioverter-defibrillators, and 5 implantable cardioverter-defibrillators. Patient comorbidities included hypertension in 10 cases, diabetes mellitus in 8, myocardial infarction in 1, and ventricular tachycardia in 8. Mean operative time was 68 minutes (42–102 minutes), and implantation time averaged 15 minutes (5–51 minutes). The average time to ambulation was 1.6 days (1–4 days). The intensive care unit stay averaged 3.3 days (1–16 days), and hospital stay averaged 6.3 days (4–16 days). Atrial fibrillation occurred in 2 patients, and there were 2 in-hospital deaths.ConclusionsThe Paracor device can be implanted in patients with heart failure and reduced left ventricular function with a high degree of success. Significant surgical complications were infrequent. The initial US experience supports the conduct of a randomized, controlled, pivotal trial

    Out-of-hospital cardiac arrest volumes and characteristics during the COVID-19 pandemic

    Get PDF
    This article is made available for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.Aim The COVID-19 pandemic has significantly impacted Emergency Medical Services (EMS) operations throughout the country. Some studies described variation in total volume of out-of-hospital cardiac arrests (OHCA) during the pandemic. We aimed to describe the changes in volume and characteristics of OHCA patients and resuscitations in one urban EMS system. Methods We performed a retrospective cohort analysis of all recorded atraumatic OHCA in Marion County, Indiana, from January 1, 2019 to June 30, 2019 and from January 1, 2020 to June 30, 2020. We described patient, arrest, EMS response, and survival characteristics. We performed paired and unpaired t-tests to evaluate the changes in those characteristics during COVID-19 as compared to the prior year. Data were matched by month to control for seasonal variation. Results The total number of arrests increased from 884 in 2019 to 1034 in 2020 (p = 0.016). Comparing 2019 to 2020, there was little difference in age [median 62 (IQR 59–73) and 60 (IQR 47–72), p = 0.086], gender (38.5% and 39.8% female, p = 0.7466, witness to arrest (44.3% and 39.6%, p = 0.092), bystander AED use (10.1% and 11.4% p = 0.379), bystander CPR (48.7% and 51.4%, p = 0.242). Patients with a shockable initial rhythm (19.2% and 15.4%, p = 0.044) both decreased in 2020, and response time increased by 18 s [6.0 min (IQR 4.5–7.7) and 6.3 min (IQR 4.7–8.0), p = 0.008]. 47.7% and 54.8% (p = 0.001) of OHCA patients died in the field, 19.7% and 19.3% (p = 0.809) died in the Emergency Department, 21.8% and 18.5% (p = 0.044) died in the hospital, 10.8% and 7.4% (p = 0.012) were discharged from the hospital, and 9.3% and 5.9% (p = 0.005) were discharged with Cerebral Performance Category score ≀ 2. Conclusion Total OHCA increased during the COVID-19 pandemic when compared with the prior year. Although patient characteristics were similar, initial shockable rhythm, and proportion of patients who died in the hospital decreased during the pandemic. Further investigation will explore etiologies of those findings

    The Physical and Genetic Framework of the Maize B73 Genome

    Get PDF
    Maize is a major cereal crop and an important model system for basic biological research. Knowledge gained from maize research can also be used to genetically improve its grass relatives such as sorghum, wheat, and rice. The primary objective of the Maize Genome Sequencing Consortium (MGSC) was to generate a reference genome sequence that was integrated with both the physical and genetic maps. Using a previously published integrated genetic and physical map, combined with in-coming maize genomic sequence, new sequence-based genetic markers, and an optical map, we dynamically picked a minimum tiling path (MTP) of 16,910 bacterial artificial chromosome (BAC) and fosmid clones that were used by the MGSC to sequence the maize genome. The final MTP resulted in a significantly improved physical map that reduced the number of contigs from 721 to 435, incorporated a total of 8,315 mapped markers, and ordered and oriented the majority of FPC contigs. The new integrated physical and genetic map covered 2,120 Mb (93%) of the 2,300-Mb genome, of which 405 contigs were anchored to the genetic map, totaling 2,103.4 Mb (99.2% of the 2,120 Mb physical map). More importantly, 336 contigs, comprising 94.0% of the physical map (∼1,993 Mb), were ordered and oriented. Finally we used all available physical, sequence, genetic, and optical data to generate a golden path (AGP) of chromosome-based pseudomolecules, herein referred to as the B73 Reference Genome Sequence version 1 (B73 RefGen_v1)

    A Single Molecule Scaffold for the Maize Genome

    Get PDF
    About 85% of the maize genome consists of highly repetitive sequences that are interspersed by low-copy, gene-coding sequences. The maize community has dealt with this genomic complexity by the construction of an integrated genetic and physical map (iMap), but this resource alone was not sufficient for ensuring the quality of the current sequence build. For this purpose, we constructed a genome-wide, high-resolution optical map of the maize inbred line B73 genome containing >91,000 restriction sites (averaging 1 site/∼23 kb) accrued from mapping genomic DNA molecules. Our optical map comprises 66 contigs, averaging 31.88 Mb in size and spanning 91.5% (2,103.93 Mb/∼2,300 Mb) of the maize genome. A new algorithm was created that considered both optical map and unfinished BAC sequence data for placing 60/66 (2,032.42 Mb) optical map contigs onto the maize iMap. The alignment of optical maps against numerous data sources yielded comprehensive results that proved revealing and productive. For example, gaps were uncovered and characterized within the iMap, the FPC (fingerprinted contigs) map, and the chromosome-wide pseudomolecules. Such alignments also suggested amended placements of FPC contigs on the maize genetic map and proactively guided the assembly of chromosome-wide pseudomolecules, especially within complex genomic regions. Lastly, we think that the full integration of B73 optical maps with the maize iMap would greatly facilitate maize sequence finishing efforts that would make it a valuable reference for comparative studies among cereals, or other maize inbred lines and cultivars

    Research Communication Costs in Australia: Emerging Opportunities and Benefits

    Full text link
    • …
    corecore