2,075 research outputs found

    Adherence to medication in bipolar disorder: a qualitative study exploring the role of patients' beliefs about the condition and its treatment.

    Get PDF
    Patients' perceptions of illness and treatment have been found to predict adherence to medication in many chronic conditions. This has not yet been fully explored in bipolar disorder (BD). The aim was to use a qualitative methodology to explore in depth the beliefs about BD and its treatment that are associated with adherence to medication prescribed for BD

    Patients' perceptions of information received about medication prescribed for bipolar disorder: Implications for informed choice

    Get PDF
    Background: Previous research suggests that patients are dissatisfied with information provided about medication prescribed for mental illness, but has not identified which aspects of information provision are unsatisfactory. Methods: 223 members of the Manic Depression Fellowship (MDF) completed the Satisfaction with Information about Medicines Scale (SIMS), a validated measure of patients' satisfaction with various aspects of information provision. Results Patients reported highest dissatisfaction with information about potential problems associated with medication; over 60% of participants reported dissatisfaction with information about the risks of side effects and whether the medication would affect their sex lives. Participants were significantly less satisfied with information about potential problems associated with their medication than people prescribed medication for HIV in a previously reported study (p < .01). Those reporting low adherence to medication had significantly lower satisfaction with information scores than those reporting high adherence (p < .05). Limitations: The sample could be prone to selection bias; participants were members of an organisation for people affected by bipolar disorder, whilst the comparator group was a NHS HIV clinic sample. Furthermore, the objective amount and type of information provided was not assessed, therefore the cause of patients' dissatisfaction is not known. Conclusions: Perceived satisfaction with information is low, particularly in relation to possible drug side-effects. Health practitioners need to elicit individuals' information requirements and tailor information to meet their needs, in order to facilitate informed choice and adherence to treatment. Moreover, they need to provide information in a manner appropriate for a patient's cognitive functioning at different illness phases

    The case for interoperability in global research

    No full text
    ”This Discussion Paper, focussing on defining interoperability in a global research sense, is the first of two that will capture the main threads of discussion from a recent symposium hosted jointly by FEAST and The University of Queensland (UQ) on Enhancing interoperability in the emerging global research order." - page 2Australian National Universit

    Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams

    Get PDF
    Background: The possible emergence of the FLASH effect—the sparing of normal tissue while maintaining tumor control—after irradiations at dose-rates exceeding several tens of Gy per second, has recently spurred a surge of studies attempting to characterize and rationalize the phenomenon. Investigating and reporting the dose and instantaneous dose-rate of ultra-high dose-rate (UHDR) particle radiotherapy beams is crucial for understanding and assessing the FLASH effect, towards pre-clinical application and quality assurance programs. Purpose: The purpose of the present work is to investigate a novel diamond-based detector system for dose and instantaneous dose-rate measurements in UHDR particle beams. Methods: Two types of diamond detectors, a microDiamond (PTW 60019) and a diamond detector prototype specifically designed for operation in UHDR beams (flashDiamond), and two different readout electronic chains, were investigated for absorbed dose and instantaneous dose-rate measurements. The detectors were irradiated with a helium beam of 145.7 MeV/u under conventional and UHDR delivery. Dose-rate delivery records by the monitoring ionization chamber and diamond detectors were studied for single spot irradiations. Dose linearity at 5&nbsp;cm depth and in-depth dose response from 2 to 16&nbsp;cm were investigated for both measurement chains and both detectors in a water tank. Measurements with cylindrical and plane-parallel ionization chambers as well as Monte-Carlo simulations were performed for comparisons. Results: Diamond detectors allowed for recording the temporal structure of the beam, in good agreement with the one obtained by the monitoring ionization chamber. A better time resolution of the order of few μs was observed as compared to the approximately 50 μs of the monitoring ionization chamber. Both diamonds detectors show an excellent linearity response in both delivery modalities. Dose values derived by integrating the measured instantaneous dose-rates are in very good agreement with the ones obtained by the standard electrometer readings. Bragg peak curves confirmed the consistency of the charge measurements by the two systems. Conclusions: The proposed novel dosimetric system allows for a detailed investigation of the temporal evolution of UHDR beams. As a result, reliable and accurate determinations of dose and instantaneous dose-rate are possible, both required for a comprehensive characterization of UHDR beams and relevant for FLASH effect assessment in clinical treatments

    Infrared receivers for low background astronomy: Incoherent detectors and coherent devices from one micrometer to one millimeter

    Get PDF
    The status of incoherent detectors and coherent receivers over the infrared wavelength range from one micrometer to one millimeter is described. General principles of infrared receivers are included, and photon detectors, bolometers, coherent receivers, and important supporting technologies are discussed, with emphasis on their suitability for low background astronomical applications. Broad recommendations are presented and specific opportunities are identified for development of improved devices

    Climacteric Lowers Plasma Levels of Platelet-Derived Microparticles: A Pilot Study in Pre-versus Postmenopausal Women

    Get PDF
    Background: Climacteric increases the risk of thrombotic events by alteration of plasmatic coagulation. Up to now, less is known about changes in platelet-(PMP) and endothelial cell-derived microparticles (EMP). Methods: In this prospective study, plasma levels of microparticles (MP) were compared in 21 premenopausal and 19 postmenopausal women. Results: No altered numbers of total MP or EMP were measured within the study groups. However, the plasma values of CD61-exposing MP from platelets/megakaryocytes were higher in premenopausal women (5,364 x 10(6)/l, range 4,384-17,167) as compared to postmenopausal women (3,808 x 10(6)/l, range 2,009-8,850; p = 0.020). This differentiation was also significant for the subgroup of premenopausal women without hormonal contraceptives (5,364 x 10(6)/l, range 4,223-15,916; p = 0.047; n = 15). Furthermore, in premenopausal women, higher plasma levels of PMP exposing CD62P were also present as compared to postmenopausal women (288 x 10(6)/l, range 139-462, vs. 121 x 10(6)/l, range 74-284; p = 0.024). This difference was also true for CD63+ PMP levels (281 x 10(6)/l, range 182-551, vs. 137 x 10(6)/l, range 64-432; p = 0.015). Conclusion: Climacteric lowers the level of PMP but has no impact on the number of EMP in women. These data suggest that PMP and EMP do not play a significant role in enhancing the risk of thrombotic events in healthy, postmenopausal women. Copyright (C) 2012 S. Karger AG, Base

    Gauge Boson Masses in the 3-d, SU(2) Gauge-Higgs Model

    Get PDF
    We study gauge boson propagators in the symmetric and symmetry broken phases of the 3-d, SU(2)SU(2) gauge-Higgs model. Correlation functions for the gauge fields are calculated in Landau gauge. They are found to decay exponentially at large distances leading to a non-vanishing mass for the gauge bosons. We find that the W-boson screening mass drops in the symmetry broken phase when approaching the critical temperature. In the symmetric phase the screening mass stays small and is independent of the scalar--gauge coupling (the hopping parameter). Numerical results coincide with corresponding calculations performed for the pure gauge theory. We find mw=0.35(1)g2Tm_w = 0.35(1)g^2T in this phase which is consistent with analytic calculations based on gap equations. This is, however, significantly smaller than masses extracted from gauge invariant vector boson correlation functions. As internal consistency check we also have calculated correlation functions for gauge invariant operators leading to scalar and vector boson masses. Finite lattice size effects have been systematically analyzed on lattices of size L2×LzL^2\times L_z with L=424L=4-24 and Lz=16128L_z = 16 - 128.Comment: 20 pages, LaTeX2e File, 8 Postscript figure

    An upper limit on the evolution of carbon monoxide from Comet Kohoutek

    Get PDF
    The rate of evolution of CO from Comet Kohoutex is presented. The observations were made approximately two months after perihelion. The rate of evolution of CO at that time was apparently less than that of CH3CN observed before perihelion
    corecore