5 research outputs found
Anchorage of lanthanum oxyhydroxides on activated carbon to increase its fluoride removal from water
Fluoride is beneficial to humans health at a
concentration of 0.7 mg L-1, but it is considered
dangerous when ingested at concentrations
above 1.5 mg L-1, which is the limit concentration
recommended by the World Health Organization
(WHO). Water pollution by fluorides occurs in many
places around the world. Therefore, more efficient
materials and technology are required to overcome
this environmental problem. The objective of this
research was to anchor lanthanum oxides on a
commercial granular activated carbon (GAC) to
remove fluorides from water. The modified GAC
was characterized by FT-IR, XRD, SEM, pKa’s
distribution, and point of zero charge (PZC) in order
to suggest how lanthanum anchors on the activated
carbon surface and also to propose the fluoride
adsorption mechanism on the modified carbon.
Adsorption experiments were carried out in batch
to study the effect of pH, presence of co-existing
anions, and the maximum adsorption capacity in
aqueous solution. These results showed that the
adsorption capacity of the modified carbon (GAC-La)
increased 5 times compared to the commercial GAC
at an initial concentration of 20 mg L-1 of F- at pH 7
and 25° C. Finally, the presence of co-existing anions
has no effect on the fluoride adsorption capacity at
concentrations below 30 mg L-1.El flúor es beneficioso para la salud humana a una
concentración de 0.7 mg L-1, pero se considera
peligroso cuando es ingerido a concentraciones
superiores a 1.5 mg L-1, el cual es el límite
recomendado por la Organización Mundial de la Salud
(OMS). La contaminación del agua por fluoruros es un
problema que se encuentra presente a nivel mundial.
Por lo tanto, se requiere invertir en el desarrollo de
nuevos materiales y tecnología más eficientes para
la remoción de contaminantes prioritarios. El objetivo
de esta investigación fue anclar óxidos de lantano
sobre un carbón activado granular (CAG) comercial
para remover fluoruros presentes en el agua. El CAG
modificado con lantano se caracterizó mediante
FT-IR, XRD, SEM, distribución de pKa´s y punto
de carga cero (PCC) con la finalidad de elucidar el
posible mecanismo de anclaje del lantano sobre la
superficie del carbón activado y el mecanismo de
adsorción de fluoruros en el carbón modificado. realizaron experimentos de adsorción en batch para
estudiar el efecto del pH, de la presencia de aniones
co-existentes, y la capacidad máxima de adsorción
en solución acuosa. Los resultados mostraron que la
capacidad de adsorción del carbón modificado con
lantano (CAG-La) aumentó 5 veces con respecto al
CAG comercial a una concentración inicial de F- de
20 mg L-1, a pH 7 y 25 °C. La presencia de aniones
co-existentes no tiene ningún efecto en la capacidad
de adsorción del fluoruro a concentraciones menores
de 30 mg L-1
Iron-modified carbon paste electrodes and their application as sensors in As(V) detection
La detección electroquímica de arsénico(V) fue
evaluada en un electrodo de pasta de carbón
modificado con partículas de hidro(óxidos) de
hierro en medio electrolítico de NaNO3. El polvo
de grafito modificado se preparó fácilmente
utilizando el método “slurry”. El material resultante
fue caracterizado mediante la determinación de su
distribución de carga superficial y punto de carga
cero, distribución de pKa’s de los grupos funcionales
superficiales, área superficial y distribución de
tamaño del poro mediante la ecuación de Brunauer-
Emmett-Teller (BET) y la identificación de las formas
cristalinas de los compuestos de hidro(óxidos) de
hierro por difracción de rayos X. Adicionalmente,
se encontró que el material modificado exhibió una
buena capacidad de remoción de As(V), incluso en
el medio electrolítico. Para la detección de As(V),
se utilizó la técnica de voltamperometría de pulso
diferencial, para la cual se aplicó un potencial de
reducción/acumulación de -1.10 V(vs. Ag/AgCl/KCl
(sat.) por 180 segundos a pH 2.5. La caracterización
fisicoquímica de los materiales modificados y
el análisis electroquímico, permitió proponer
un mecanismo de reducción de As(V) sobre la
superficie del electrodo. El límite de detección (LOD) de As(V) alcanzado fue de 19.40 μg/L, por lo cual
este electrodo podría ser potencialmente aplicado
como sensor en la detección de este contaminante
en muestras de aguaThe electrochemical detection of arsenic (V)
[As(V)] was evaluated on a carbon paste electrode
modified with iron hydro(oxide) particles in the
presence of NaNO3 salt used as electrolytic media
in the experiments. The modified graphite powder
was easily prepared using the slurry method.
The resulting material was examined by surface
charge and pKa’s distribution, point of zero charge,
Brunauer-Emmett-Teller (BET) surface area and
pore size distribution, potentiometric titration and
X-ray diffraction. Adsorption experiments with the
modified materials exhibited good As(V) removal
capacity even in the presence of electrolytic media.
For the As(V) detection, differential pulse voltammetry
technique was used by the application of reduction
potential of -1.10 V for 180 s at pH 2.5. The detailed
physicochemical characterization of modified
materials and electrochemical analysis allowed to
propose a reduction mechanism of As(V) on the
electrode surface. Detection limit of 10 μg/L can be
achieved for As(V), therefore this electrode could
potentially be applied as a sensor for the detection of
this pollutant in water sample
Bioreactors packed with activated carbon fibers as redox mediators in the anaerobic biotransformation of 4-Nitrophenol to 4-Aminophenol
The role of functional groups on the surface of
activated carbons is of great interest in biological
redox processes because they could improve the
rate of biotransformation of toxic compounds and
reduce costs of water treatment. In this study, we
used activated carbon fibers (ACFs) as biological
supports and redox mediators for the continuous
biotransformation of 4-nitrophenol (4-NP) to
4-aminophenol (4-AP). Different ACFs were prepared
from the original material (AW), including HNO3-treated
ACF (AW-OX), and redox-active anthraquinone-2,6-
disulfonate anchored on ACF surface (AW-AQDS).
These ACFs were characterized by potentiometric
titrations (point of zero charge and Boehm), FT-IR,
and N2-adsorption (BET method). The ACF-packed
bed bioreactors (AW, AW-OX and AW-AQDS) with
anoxic granular biomass were evaluated for their
ability to reduce 4-NF to 4-AP under continuous
conditions, and compared to a control bioreactor with
only anoxic granular biomass. Our results show that
ACFs with a higher concentration of carbonyl groups
AW-OX > AW-AQDS > AW (1.3 > 1.0 > 0.8 meq/g)
improved the biotransformation of 4-NF by 2.11 >
1.97 > 1.47 – fold, respectively, as compared to the
control bioreactor.La función de los grupos funcionales superficiales
sobre los carbones activados es de gran interés
en procesos biológicos con actividad redox porque
tales grupos pueden incrementar la eficiencia de
biotransformación de compuestos tóxicos y con esto
reducir los costos del tratamiento de aguas. En este
estudio se usaron fibras de carbón activado (FCAs)
como soportes biológicos y mediadores redox para
la biotransformación contínua de 4-nitrofenol (4-NF)
hacia 4-aminofenol (4-AF) en condiciones anaerobias.
Diversas FCAs se prepararon a partir del material
original (AW) incluyendo FCAs tratadas con ácido
nítrico (AW-OX) y modificadas con antraquinina-
2,6-disulfonato (AW-AQDS). Éstas FCAs fueron
caracterizadas por titulaciones potenciométricas
(punto de carga cero ó PCC, Boehm), FT-IR, y
adsorción de N2 a bajas temperaturas (método BET). Los reactores empacados con FCAs (AW, AW-OX
y AW-AQDS) y con biomasa granular anaerobia
fueron evaluados por su capacidad para reducir
continuamente el 4-NF a 4-AF. Estos resultados
se compararon con el reactor control que carecía
de FCAs en su interior y sólo contenía biomasa
anaerobia granular. Los resultados muestran que las
FCAs con una alta concentración de grupos carbonilo
AW-OX > AW-AQDS > AW (1.3 > 1.0 > 0.8 meq/g)
mejoraron la biotransformación de 4-NF por 2.11 >
1.97 > 1.47 – veces, respectivamente, comparando
con el reactor control
Adsorbentes híbridos oxihidróxidos metálicos-carbón para remover contaminantes prioritarios del agua: fluoruro y arsénico
Water polluted with fluoride (F-
) and arsenic (As) is
a problem of global relevance. The groundwater of
several countries exceeds the allowable concentration
limits for these compounds as recommended by the
World Health Organization (WHO), thus posing a
serious human health risk. For this reason, F-
and
As are considered priority pollutants that determine
water quality. To eliminate or reduce the concentration
of these contaminants, several processes have been
implemented such as: ion exchange, precipitation–
coagulation, electrodialysis, nano-filtration, reverse
osmosis, and Donnan dialysis. However, most of
these methods often involve high operating and
maintenance costs. The use of adsorbents that
are specifically designed for the removal of these
elements represent a viable alternative for future
water treatments system. An attractive option is
the use of activated carbon (AC) as an adsorbent
material. Nevertheless, limitations related to its
capacity and selectivity must be overcome. The
modification of the activated carbons surface with
metal oxyhydroxides nanoparticles has the potential
to selectively remove these contaminants. The
biggest challenge is controlling the anchorage of the
oxyhydroxide nanoparticles on the AC surface. Our
research group has contributed in recent years to
this research area by synthesizing hybrid adsorbents
based on metal oxyhydroxides nanoparticles-AC with
elevated adsorption capacities and chemical stability,
this considering the relationship among surface area,
charge distribution, functional groups, metal content,
and contaminant uptake.La contaminación del agua por fluoruros (F-
) y arsénico (As) es un problema de importancia mundial, ya que
el agua subterránea de varios países excede los
límites permisibles establecidos por la Organización
Mundial de la Salud (OMS), lo cual representa un
riesgo para la salud humana. Por esta razón, el
F- y el As se consideran contaminantes prioritarios
que determinan la calidad del agua. Para eliminar
o reducir la concentración de estos contaminantes
se han implementado diversos procesos, tales
como: intercambio iónico, precipitación-coagulación,
electrodiálisis, nanofiltración, ósmosis inversa, y
diálisis Donnan; sin embargo, la mayoría de estos
métodos a menudo implican costos de operación
elevados y mantenimiento continuo. El uso de
adsorbentes diseñados específicamente para
eliminar estos elementos representa una alternativa
con gran potencial para ser aplicados a corto plazo
en sistemas de tratamiento de agua. Una opción
atractiva para mitigar la contaminación del agua
por F-
y As es el uso de carbón activado (CA) como
material adsorbente. Sin embargo, este material
tiene algunas limitaciones relacionadas con su
capacidad y selectividad que deben ser superadas.
La modificación de carbón activado con partículas
de oxihidróxidos metálicos de tamaño nanométrico
tiene el potencial de eliminar selectivamente estos
contaminantes, sin embargo, el mayor reto es el
anclaje de estos metales en la superficie del CA.
Nuestro grupo de investigación ha contribuido en los
últimos años a esta área de investigación mediante
la síntesis de adsorbentes híbridos basados en
oxihidróxidos metálicos-carbón con capacidad de
adsorción elevada. Lo anterior considerando la
relación entre el área específica, distribución de
carga, grupos funcionales, contenido de metal y la
capacidad de adsorción
Study of the adsorption-desorption of Cu2+, Cd2+ and Zn2+ in single and binary aqueous solutions using oxygenated carbons prepared by Microwave Technology
In the present work was studied the adsorption-desorption of heavy metals from aqueous solutions using carbonaceous materials prepared with a technology that combines radiant and microwave heating. Three optimum carbons O-Cu, O-Cd and O-Zn were prepared and characterized using elemental analysis, potentiometric titration, nitrogen adsorption isotherms at - 196 °C, SEM/EDX analysis, and temperature programmed desorption (TPD). The three optimum carbons had very high oxygen contents mainly ascribed to surface functional groups of acidic nature. In contrast, the porosity of the carbons was very limited with specific surface areas being < 50 m2/g. Liquid adsorption isotherms were carried out and capacities of the three optimum carbons were 67, 26 and 24 mg/g for Cu2 +, Cd2 + and Zn2 +, respectively. The higher capacity of the O-Cu carbon was explained in terms of the higher electronegativity of metallic Cu and the theory of hard and soft acids and bases (HSAB) defined by Pearson, when compared with both Cd and Zn atoms. Additionally, the desorption percentage of heavy metals was lower than 10%