    Measurement of the Λ hyperon lifetime

    Get PDF
    A new, more precise measurement of the Lambda hyperon lifetime is performed using a large data sample of Pb-Pb collisions at root s(NN) = 5.02 TeV with ALICE. The Lambda and (Lambda)_bar hyperons are reconstructed at midrapidity using their two-body weak decay channel Lambda -> p + pi(-) and (Lambda)_bar -> (p )_bar + pi(+). The measured value of the Lambda lifetime is tau(Lambda) = [261.07 +/- 0.37(stat.) +/- 0.72o(syst)] ps. The relative difference between the lifetime of Lambda and (Lambda)_bar, which represents an important test of CPT invariance in the strangeness sector, is also measured. The obtained value (tau(Lambda) - tau((Lambda)_bar))/tau(Lambda) = (0.0013 +/- 0.0028(stat.) +/- 0.0021(syst.) is consistent with zero within the uncertainties. Both measurements of the. hyperon lifetime and of the relative difference between tau(Lambda) and tau((Lambda)_bar) are in agreement with the corresponding world averages of the Particle Data Group and about a factor of three more precise

    The Future of Dancefloors: Building More Flexible, Open and Innovative Clubbing Experiences

    Get PDF
    Nightclubs across the world are in a state of crisis due to COVID-19, and neither inaction or ‘business as usual’ are viable options if the industry is to survive it. It has never been more important to question, innovate and re-imagine the status quo

    Geometric Parameterization of J/ΚJ/\Psi Absorption in Heavy Ion Collisions

    Get PDF
    We calculate the survival probability of J/ΚJ/\Psi particles in various colliding systems using a Glauber model. An analysis of recent data has reported a J/ΚJ/\Psi-nucleon breakup cross section of 6.2±\pm0.7 mb derived from an exponential fit to the ratio of J/ΚJ/\Psi to Drell-Yan yields as a function of a simple, linearly-averaged mean path length through the nuclear medium. Our calculations indicate that, due to the nature of the calculation, this approach yields an apparent breakup cross section which is systematically lower than the actual value.Comment: LaTex, 7 pages, 2 figure

    A model-independent analysis of the dependence of the anomalous J/psi suppression on the number of participant nucleons

    Full text link
    A recently published experimental dependence of the J/psi to Drell-Yan ratio on the measured, by a zero degree calorimeter, forward energy E_ZDC in Pb+Pb collisions at the CERN SPS is analyzed. Using a model-independent approach it is shown that the data are at variance with an earlier published experimental dependence of the same quantity on the transverse energy of neutral hadrons E_T. The discrepancy is related to a moderate centrality region: 100 < N_p < 200 (N_p is the number of participant nucleons) and is peculiar only to the data obtained within the `minimum bias' analysis (using the `theoretical Drell-Yan'). This could result from systematic experimental errors in the minimum bias sample. A possible source of the errors is discussed.Comment: 10 pages, LaTeX, 3 PS-figures. V2: Misprints are correcte

    Dual energy imaging in mammography: Cross-talk study in a Si array detector

    Get PDF
    Abstract One of the main limitation to the extensive use of breast-cancer screening as a prevention method is the relatively high X-ray dose released to the patient. A new approach is under study in which two quasi-monochromatic beamswith mean energies of 18.0 and 36.0 keV -are produced simultaneously, starting from an X-ray tube, by means of a monochromator based on a pyrolytic graphite crystal. The two beams are superimposed in space. The removal of the energy components with low content of diagnostic information from the spectrum, leads to a reduction of the dose released to patients maintaining (or improving) the image quality. The two quasi-monochromatic beams impinge on the patient and then are detected with a solid-state array detector; the image results as the difference between the transmitted intensities of the two detected beams. In this work, the performances of two different electronic readouts and three pixel widths of a silicon position sensitive array detector are simulated and described in order to minimize cross-talk effects between adjacent pixels. The use of a detector with spectrometric capabilities is necessary to separate, by means of thresholds, the high energy photons from the low energy ones

    A new measurement of J/psi suppression in Pb-Pb collisions at 158 GeV per nucleon

    Full text link
    We present a new measurement of J/psi production in Pb-Pb collisions at 158 GeV/nucleon, from the data sample collected in year 2000 by the NA50 Collaboration, under improved experimental conditions with respect to previous years. With the target system placed in vacuum, the setup was better adapted to study, in particular, the most peripheral nuclear collisions with unprecedented accuracy. The analysis of this data sample shows that the (J/psi)/Drell-Yan cross-sections ratio measured in the most peripheral Pb-Pb interactions is in good agreement with the nuclear absorption pattern extrapolated from the studies of proton-nucleus collisions. Furthermore, this new measurement confirms our previous observation that the (J/psi)/Drell-Yan cross-sections ratio departs from the normal nuclear absorption pattern for semi-central Pb-Pb collisions and that this ratio persistently decreases up to the most central collisions.Comment: 19 pages, 10 figures. Submitted to Eur. Phys. J.

    X-ray grating interferometry design for the 4D GRAPH-X system

    Get PDF
    The 4D GRAPH-X (Dynamic GRAting-based PHase contrast x-ray imaging) project aims at developing a prototype of an x-ray grating-based phase-contrast imaging scanner in a laboratory setting, which is based on the Moire single-shot acquisition method in order to be optimized for analysing moving objects (in the specific case, a dynamic thorax phantom), that could evolve into a suitable tool for biomedical applications although it can be extended to other application fields. When designing an x-ray Talbot-Lau interferometer, high visibility and sensitivity are two important figures of merit, strictly related to the performance of the system in obtaining high quality phase contrast and dark-field images. Wave field simulations are performed to optimize the setup specifications and construct a high-resolution and high-sensitivity imaging system. In this work, the design of a dynamic imaging setup using a conventional milli-focus x-ray source is presented. Optimization by wave front simulations leads to a symmetric configuration with 5.25 mu m pitch at third Talbot order and 45 keV design energy. The simulated visibility is about 22%. Results from GATE based Monte Carlo simulations show a 19% transmission percentage of the incoming beam into the detector after passing through all the gratings and the sample. Such results are promising in view of building a system optimized for dynamic imaging

    Radiation damage of silicon strip detectors in the NA50 experiment

    Get PDF
    Abstract During operation of the multiplicity detector in the NA50 experiment the single sided AC-coupled p-on-n silicon strip detectors were exposed to charged particle fluences up to 10 14 eq n/cm 2 and ionising doses up to 20 Mrad, with a very non-uniform radiation spatial distribution. Radiation effects in the detectors observed during the '96 lead ion run as well as results of the post-run measurements are presented in this paper
    • 