394 research outputs found

    Prospective Evaluation of Patient Satisfaction, and Surgeon and Patient Trainer Assessment of the Coloplast Titan One Touch Release Three‐Piece Inflatable Penile Prosthesis

    Full text link
    Introduction.  A single‐armed, prospective, multicenter international study evaluated the redesigned Coloplast Titan One Touch Release (OTR) pump inflatable penile prosthesis. The OTR pump has a unique release valve that permits deflation of the implant with one squeeze of opposing touch pads. Aims.  To assess the impact of a new penile prosthesis design, the Titan OTR, on patient ease of operation. Furthermore, to assess patient satisfaction, surgeon acceptance, and the ease with which patients were trained in device operation in the clinic setting. Methods.  A total of 113 eligible patients from eight centers were recruited from men presenting with erectile dysfunction without prior prosthetic implantation. The subjects had a mean age of 61 years, and had a number of comorbidities, including diabetes (31.9%), hypertension (34.5%), and Peyronie's disease (23.9%). All underwent implantation of the study device. Main Outcome Measures.  Questionnaires were used to capture patient satisfaction as well as physician feedback on ease of implantation and patient education. A paired analysis was completed for patient satisfaction at 6 (N = 96) and 12 (N = 90) months. Results.  Overall satisfaction with the device was 90.6% and 90.0% at 6 and 12 months, respectively. The primary end point, ease of deflation, was seen in 70.8% and 73.3% at these two time points, with the 12‐month value statistically better than historical controls. Physicians overwhelmingly reported straightforward/simple intraoperative product preparation (97.3%) and equivalent or easier training compared with their previous pump of choice (96.4%). Adverse events for all subjects (N = 113) included removal of the device in four cases (3.5%) for infection and one case for chronic pain (0.8%). Conclusions.  The Titan OTR represents an advance in penile prosthetic technology that is well accepted by patients and physicians. The study design allowed for realistic evaluation of the new technology aimed at enhancing clinical outcomes. Ohl DA, Brock G, Ralph D, Bogache W, Jones L, Munarriz R, Levine L, and Ritenour C. Prospective evaluation of patient satisfaction, and surgeon and patient trainer assessment of the Coloplast Titan One Touch Release three‐piece inflatable penile prosthesis. J Sex Med 2012;9:2467–2474.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/93661/1/j.1743-6109.2012.02819.x.pd

    Detection of early antiangiogenic effects in human colon adenocarcinoma xenografts: in vivo changes of tumor blood volume in response to experimental VEGFR tyrosine kinase inhibitor

    Get PDF
    Antiangiogenesis is emerging as efficient strategy for targeting and potentially eliminating neoplastic tumor vessels. The main goal of this study was to establish whether absolute tumor blood volume (V(b)) change could be used as an early predictor of antiangiogenesis in ectopic and orthotopic colon carcinomas. To assess therapy-induced changes of V(b), we did comparative analysis of signal intensities in tumors and muscle using steady-state magnetic resonance imaging (MRI) assisted with an intravascular paramagnetic contrast agent [gadolinium-labeled protected graft copolymer (PGC-Gd)]. Athymic mice with implanted human MV522 tumors were treated with vascular endothelial growth factor type 2 receptor tyrosine kinase inhibitor (VEGFR2-TKI) that has been shown to inhibit VEGFR2 phosphorylation and tumor growth in vivo. Animals were imaged either after a single day or after a 1-week course of treatments. The measured V(b) in ectopic tumors was 2.5 +/- 1.5% of total tissue volume 1 week after the implantation (n = 8). Two doses of VEGFR2-TKI (25 mg/kg, p.o., b.i.d.) resulted in a decrease of V(b) to 1.3 +/- 0.3%. In orthotopic tumors, the measured V(b) was initially higher (11.9 +/- 2.0%); however, VEGFR2-TKI treatment also resulted in a statistically significant decrease of V(b). The absolute V(b) was not affected in the muscle as a result of treatments. MRI measurements were corroborated by using isotope and correlative histology experiments. Our results show that steady-state MRI is highly sensitive to early antiangiogenic effects caused by small molecule drugs
    corecore