106 research outputs found

    Low temperature pyrolysis of thin film composite polyphosphazene membranes for hot gas separation

    Get PDF
    Highly selective thin-film composite membranes for hot hydrogen sieving are prepared via the pyrolysis of thin cyclomatric polyphenoxy phosphazene films that are prepared via a non-conventional interfacial polymerization of hexachlorocyclotriphosphazene with 1,3,5-trihydroxybenzene or m-dihydroxybenzene. The presence of the cyclic phosphazene ring within the weakly branched polymer films gives rise to a distinct thermal degradation evolution, with an onset temperature of around 200 °C. For the trihydroxybenzene derived material, the hydrogen permselectivity of the films shows a maximum pyrolysis temperature of around 450 °C. At this temperature a compact atomic structure is obtained that comprises mostly disordered carbon and accommodates P–O–C and P–O–P bonds. During thermal treatment, these films reveal molecular sieving with permselectivities exceeding 100 for H2/N2, H2/CH4, and H2/CO2, and a hydrogen permeance of 2 × 10−10 to 1.5 × 10−8 mol/m2/s/Pa (0.6-44.8GPU), at 200 °C. At ambient temperatures, thin films are very effective barriers for small gas molecules. Because of the inexpensive facile synthesis and low- temperature pyrolysis, the polyphosphazene films have the potential for use in high-temperature industrial gas separations, as well as for use as barriers such as liners in high- pressure hydrogen storage vessels at ambient temperature.</p

    A compound current limiter and circuit breaker

    Get PDF
    © 2019 by the authors. Licensee MDPI, Basel, Switzerland. The protection of sensitive loads against voltage drop is a concern for the power system. A fast fault current limiter and circuit breaker can be a solution for rapid voltage recovery of sensitive loads. This paper proposes a compound type of current limiter and circuit breaker (CLCB) which can limit fault current and fast break to adjust voltage sags at the protected buses. In addition, it can act as a circuit breaker to open the faulty line. The proposed CLCB is based on a series L-C resonance, which contains a resonant transformer and a series capacitor bank. Moreover, the CLCB includes two anti-parallel power electronic switches (a diode and an IGBT) connected in series with bus couplers. In order to perform an analysis of CLCB performance, the proposed structure was simulated using MATLAB. In addition, an experimental prototype was built, tested, and the experimental results were reported. Comparisons show that experimental results were in fair agreement with the simulation results and confirm CLCB’s ability to act as a fault current limiter and a circuit breaker

    Fibroblast growth factor-23 in patients with systemic sclerosis: A case–control study

    Get PDF
    AbstractBackgroundFibroblast growth factor-23 (FGF-23) is actively involved in phosphate homeostasis and skeletogenesis.Aim of the workTo assess the serum level of FGF-23 in systemic sclerosis (SSc) patients (both diffuse dSSc and limited lSSc subtypes) in order to find if it has a role in the pathogenesis of the disease and study its relation to the clinical manifestations.Patients and methodsThe study included 30 dSSc patients, 30 lSSc and 28 age and sex matched controls. In patients, clinical examination and laboratory investigations were performed and Medsger severity scale assessed. Serum FGF-23 was measured using ELISA.ResultsThe age of dSSc patients was 36.94±9.89years and the lSSc 38.36±10.04years. The serum FGF-23 level was 23.44±14.86pg/ml in dSSc patients, 20.01±13.92pg/ml in lSSc patients and 23.09±11.45pg/ml in the control (p=0.58). No significant difference in the FGF-23 level was found according to the presence of lung fibrosis (p=0.6). There was no significant difference in FGF levels among patients according to the severity (p=0.39). In SSc patients there was a significant correlation between FGF and serum phosphorus especially in dSSc patients (r=0.6, p=0.003). Serum urea significantly correlated with FGF-23 in those with dSSc (r=0.46, p=0.037). There was no significant difference in the FGF-23 levels (p=0.18) between those with a normal and impaired glomerular filtration rate.ConclusionThe mean serum level of FGF-23 in this study showed no significant difference between systemic sclerosis patients and their subtypes with the normal subjects. It seems to have no role in the clinical manifestations of the disease

    Nonaqueous Interfacial Polymerization-Derived Polyphosphazene Films for Sieving or Blocking Hydrogen Gas

    Get PDF
    A series of cyclomatrix polyphosphazene films have been prepared by nonaqueous interfacial polymerization (IP) of small aromatic hydroxyl compounds in a potassium hydroxide dimethylsulfoxide solution and hexachlorocyclotriphosphazene in cyclohexane on top of ceramic supports. Via the amount of dissolved potassium hydroxide, the extent of deprotonation of the aromatic hydroxyl compounds can be changed, in turn affecting the molecular structure and permselective properties of the thin polymer networks ranging from hydrogen/oxygen barriers to membranes with persisting hydrogen permselectivities at high temperatures. Barrier films are obtained with a high potassium hydroxide concentration, revealing permeabilities as low as 9.4 × 10-17 cm3 cm cm-2 s-1 Pa-1 for hydrogen and 1.1 × 10-16 cm3 cm cm-2 s-1 Pa-1 for oxygen. For films obtained with a lower concentration of potassium hydroxide, single gas permeation experiments reveal a molecular sieving behavior, with a hydrogen permeance of around 10-8 mol m-2 s-1 Pa-1 and permselectivities of H2/N2 (52.8), H2/CH4 (100), and H2/CO2 (10.1) at 200 °C.</p

    A multi-inductor h bridge fault current limiter

    Get PDF
    © 2019 by the authors. Current power systems will suffer from increasing pressure as a result of an upsurge in demand and will experience an ever-growing penetration of distributed power generation, which are factors that will contribute to a higher of incidence fault current levels. Fault current limiters (FCLs) are key power electronic devices. They are able to limit the prospective fault current without completely disconnecting in cases in which a fault occurs, for instance, in a power transmission grid. This paper proposes a new type of FCL capable of fault current limiting in two steps. In this way, the FCLs’ power electronic switches experience significantly less stress and their overall performance will significantly increase. The proposed device is essentially a controllable H bridge type fault current limiter (HBFCL) that is comprised of two variable inductances, which operate to reduce current of main switch in the first stage of current limiting. In the next step, the main switch can limit the fault current while it becomes open. Simulation studies are carried out using MATLAB and its prototype setup is built and tested. The comparison of experimental and simulation results indicates that the proposed HBFCL is a promising solution to address protection issues

    Comparing amine- and ammonium functionalized silsesquioxanes for large scale synthesis of hybrid polyimide high-temperature gas separation membranes

    Get PDF
    PolyPOSS-imide membranes are promising for separating H2 from larger molecules (CO2, N2, CH4) at temperatures up to 300 °C. Their fabrication involves two steps: interfacial polymerization of POSS and 6FDA, followed by thermal imidization. This work provides a systematic study of the effects of cations on membrane properties and performance. For this, two distinct POSS molecules were used: functionalized with -NH3+Cl− or, so far unexplored, -NH2. The ammonium groups are partially deprotonated by using three different bases, LiOH, NaOH, and KOH. We demonstrate that the introduced cations affect the film thickness but not the molecular composition of the polyamic acid. All polyamic acids can be imidized, but the cations reduce the imidization kinetics as well as the loss of organic crosslinkers. For flat disc membranes, at 200 °C, the absence of cations results in comparable permeability combined with higher selectivity for H2/N2. This, and the possibility to discard adding a base, motivated a scale-up study of the new POSS. For tubular membranes, much higher ideal and mixed gas selectivities are found than for membranes where NaOH was added. Results indicate that the new route allows more reproducible production of defect free membranes and has potential for larger-scale polyPOSSimide fabrication.publishedVersio

    A combined fMRI and DTI examination of functional language lateralization and arcuate fasciculus structure: Effects of degree versus direction of hand preference Author links open overlay panel

    Get PDF
    The present study examined the relationship between hand preference degree and direction, functional language lateralization in Broca’s and Wernicke’s areas, and structural measures of the arcuate fasciculus. Results revealed an effect of degree of hand preference on arcuate fasciculus structure, such that consistently-handed individuals, regardless of the direction of hand preference, demonstrated the most asymmetric arcuate fasciculus, with larger left versus right arcuate, as measured by DTI. Functional language lateralization in Wernicke’s area, measured via fMRI, was related to arcuate fasciculus volume in consistent-left-handers only, and only in people who were not right hemisphere lateralized for language; given the small sample size for this finding, the future investigation is warranted. Results suggest handedness degree may be an important variable to investigate in the context of neuroanatomical asymmetries

    Stability investigation of polyPOSS-imide membranes for H2 purification and their application in the steel industry

    Get PDF
    In the present work, the high-temperature and long-term hydrothermal stability of novel polyPOSS-imide membranes for high-temperature hydrogen separation is investigated. The polyPOSS-imide membranes are found to exhibit an appropriate stability up to 300 C. Above this temperature the membrane selectivity rapidly decreases, which is seemingly related to changes in the molecular structure coupled to silanol condensation forming siloxane groups. Surprisingly, the exposure of the membrane to temperatures of up to 300 C even increases the H2 permeance together with the selective feature of the polyPOSS-imide layer. Subsequently, the long-term hydrothermal stability of the polyPOSS-imide membranes was investigated over a period of close to 1000 h at 250 C exposing the membrane to 10 mol% steam in the feed. An increase in H2/CH4 selectivity was observed upon water addition, and even though a minor drop was noticed over time during the hydrothermal operation, the selectivity exceeds the initial selectivity obtained in the dry feed atmosphere. After the removal of steam from the feed, the performance returns to its original state prior to the exposure to any steam showing appropriate steam stability of the polyPOSS-imide membranes. A conceptual process design and assessment was performed for application of these membranes involving a combination of carbon reuse and electrification of the steel making process with co-production of hydrogen. The results indicate a CO2 avoidance of 14%. The CO2 reduction achieved using renewable electricity in the proposed scheme is a factor 2.76 higher compared to a situation where the same renewable electricity would be fed in the electricity grid.publishedVersio
    corecore