1,746 research outputs found
Discrete structures in continuum descriptions of defective crystals
I discuss various mathematical constructions that combine together to provide a natural setting for discrete and continuum geometric models of defective crystals. In particular I provide a quite general list of `plastic strain variables', which quantifies inelastic behaviour, and exhibit rigorous connections between discrete and continuous mathematical structures associated with crystalline materials that have a correspond-ingly general constitutive specification
Ruptured renal artery aneurysm during pregnancy, a clinical dilemma
BACKGROUND: Rupture of a renal artery aneurysm (RAA) during pregnancy is a rare event, with a high mortality rate for both mother and fetus. Increased blood flow and intra-abdominal pressure, and vascular changes secondary to increased steroid production are postulated as contributory to the increased risk of rupture during pregnancy. CASE PRESENTATION: We present here a case report of total avulsion of solitary kidney secondary to rupture of RAA in a pregnant patient with congenital absence of the contralateral kidney. The main indication for nephrectomy was severely damaged kidney. Diagnosis was made during operation and both mother and fetus were saved. There are no previous reports of an intact renal artery aneurysm diagnosed either antepartum or postpartum. CONCLUSION: The possibility of a ruptured RAA should be considered in pregnant women with evidence of retroperitoneal hemorrhage. This case was unusual because it occurred in a solitary kidney, during the third trimester of pregnancy
Reduction of low- and high-grade cervical abnormalities associated with high uptake of the HPV bivalent vaccine in Scotland
In Scotland, a national HPV immunisation programme began in 2008 for 12-13 year olds, with a catch-up campaign from 2008-2011 for those under the age of 18. To monitor the impact of HPV immunisation on cervical disease at the population level, a programme of national surveillance was established. We analysed colposcopy data from a cohort of women born between 1988-1992 who entered the Scottish Cervical Screening Programme (SCSP) and were aged 20-21 in 2008-2012. By linking datasets from the SCSP and colposcopy services, we observed a significant reduction in diagnoses of cervical intraepithelial neoplasia 1 (CIN 1) (RR 0.71, 95% CI 0.58 to 0.87, p=0.0008), CIN 2 (RR 0.5, 95% CI 0.4, 0.63, p<0.0001) and CIN 3 (RR 0.45, 95% CI 0.35 to 0.58, p< 0.0001) for women who received 3 doses of vaccine compared with unvaccinated women. To our knowledge, this is one of the first studies to show a reduction of low and high grade cervical intraepithelial neoplasia associated with high uptake of the HPV bivalent vaccine at the population level. These data are very encouraging for countries that have achieved high HPV vaccine uptake
The flipped classroom: for active, effective and increased learning – especially for low achievers
Dimensionality of Carbon Nanomaterials Determines the Binding and Dynamics of Amyloidogenic Peptides: Multiscale Theoretical Simulations
Experimental studies have demonstrated that nanoparticles can affect the rate of protein self-assembly, possibly interfering with the development of protein misfolding diseases such as Alzheimer's, Parkinson's and prion disease caused by aggregation and fibril formation of amyloid-prone proteins. We employ classical molecular dynamics simulations and large-scale density functional theory calculations to investigate the effects of nanomaterials on the structure, dynamics and binding of an amyloidogenic peptide apoC-II(60-70). We show that the binding affinity of this peptide to carbonaceous nanomaterials such as C60, nanotubes and graphene decreases with increasing nanoparticle curvature. Strong binding is facilitated by the large contact area available for π-stacking between the aromatic residues of the peptide and the extended surfaces of graphene and the nanotube. The highly curved fullerene surface exhibits reduced efficiency for π-stacking but promotes increased peptide dynamics. We postulate that the increase in conformational dynamics of the amyloid peptide can be unfavorable for the formation of fibril competent structures. In contrast, extended fibril forming peptide conformations are promoted by the nanotube and graphene surfaces which can provide a template for fibril-growth
Precision Measurement of the Mass of the h_c(1P1) State of Charmonium
A precision measurement of the mass of the h_c(1P1) state of charmonium has
been made using a sample of 24.5 million psi(2S) events produced in e+e-
annihilation at CESR. The reaction used was psi(2S) -> pi0 h_c, pi0 -> gamma
gamma, h_c -> gamma eta_c, and the reaction products were detected in the
CLEO-c detector.
Data have been analyzed both for the inclusive reaction and for the exclusive
reactions in which eta_c decays are reconstructed in fifteen hadronic decay
channels. Consistent results are obtained in the two analyses. The averaged
results of the present measurements are M(h_c)=3525.28+-0.19 (stat)+-0.12(syst)
MeV, and B(psi(2S) -> pi0 h_c)xB(h_c -> gamma eta_c)= (4.19+-0.32+-0.45)x10^-4.
Using the 3PJ centroid mass, Delta M_hf(1P)= - M(h_c) =
+0.02+-0.19+-0.13 MeV.Comment: 9 pages, available through http://www.lns.cornell.edu/public/CLNS/,
submitted to PR
Precision Measurement of B(D+ -> mu+ nu) and the Pseudoscalar Decay Constant fD+
We measure the branching ratio of the purely leptonic decay of the D+ meson
with unprecedented precision as B(D+ -> mu+ nu) = (3.82 +/- 0.32 +/-
0.09)x10^(-4), using 818/pb of data taken on the psi(3770) resonance with the
CLEO-c detector at the CESR collider. We use this determination to derive a
value for the pseudoscalar decay constant fD+, combining with measurements of
the D+ lifetime and assuming |Vcd| = |Vus|. We find fD+ = (205.8 +/- 8.5 +/-
2.5) MeV. The decay rate asymmetry [B(D+ -> mu+ nu)-B(D- -> mu- nu)]/[B(D+ ->
mu+ nu)+B(D- -> mu- nu)] = 0.08 +/- 0.08, consistent with no CP violation. We
also set 90% confidence level upper limits on B(D+ -> tau+ nu) < 1.2x10^(-3)
and B(D+ -> e+ nu) < 8.8x10^(-6).Comment: 24 pages, 11 figures and 6 tables, v2 replaced some figure vertical
axis scales, v3 corrections from PRD revie
J/psi and psi(2S) Radiative Transitions to eta_c
Using 24.5 million psi(2S) decays collected with the CLEO-c detector at CESR
we present the most precise measurements of magnetic dipole transitions in the
charmonium system. We measure B(psi(2S)->gamma eta_c) =
(4.32+/-0.16+/-0.60)x10^-3, B(J/psi->gamma eta_c)/B(psi(2S)->gamma eta_c) =
4.59+/-0.23+/-0.64, and B(J/psi->gamma eta_c) = (1.98+/-0.09+/-0.30)%. We
observe a distortion in the eta_c line shape due to the photon-energy
dependence of the magnetic dipole transition rate. We find that measurements of
the eta_c mass are sensitive to the line shape, suggesting an explanation for
the discrepancy between measurements of the eta_c mass in radiative transitions
and other production mechanisms.Comment: 11 pages, 3 figure
Inclusive chi_bJ(nP) Decays to D0 X
Using Upsilon(2S) and Upsilon(3S) data collected with the CLEO III detector
we have searched for decays of chi_bJ to final states with open charm. We fully
reconstruct D0 mesons with p_D0 > 2.5 GeV/c in three decay modes (K-pi+,
K-pi+pi0, and K-pi-pi+pi+) in coincidence with radiative transition photons
that tag the production of one of the chi_bJ(nP) states. We obtain significant
signals for the two J=1 states. Recent NRQCD calculations of chi_{bJ}(nP) --> c
cbar X depend on one non-perturbative parameter per chi_bJ triplet. The
extrapolation from the observed D0 X rate over a limited momentum range to a
full c cbar X rate also depends on these same parameters. Using our data to fit
for these parameters, we extract results which agree well with NRQCD
predictions, confirming the expectation that charm production is largest for
the J=1 states. In particular, for J=1, our results are consistent with c cbar
g accounting for about one-quarter of all hadronic decays.Comment: Version 2 updates include corrections to important errors in Table V
and VII column headers which summarize results, and additional minor edits.
17 pages, available through http://www.lns.cornell.edu/public/CLNS
CMB Telescopes and Optical Systems
The cosmic microwave background radiation (CMB) is now firmly established as
a fundamental and essential probe of the geometry, constituents, and birth of
the Universe. The CMB is a potent observable because it can be measured with
precision and accuracy. Just as importantly, theoretical models of the Universe
can predict the characteristics of the CMB to high accuracy, and those
predictions can be directly compared to observations. There are multiple
aspects associated with making a precise measurement. In this review, we focus
on optical components for the instrumentation used to measure the CMB
polarization and temperature anisotropy. We begin with an overview of general
considerations for CMB observations and discuss common concepts used in the
community. We next consider a variety of alternatives available for a designer
of a CMB telescope. Our discussion is guided by the ground and balloon-based
instruments that have been implemented over the years. In the same vein, we
compare the arc-minute resolution Atacama Cosmology Telescope (ACT) and the
South Pole Telescope (SPT). CMB interferometers are presented briefly. We
conclude with a comparison of the four CMB satellites, Relikt, COBE, WMAP, and
Planck, to demonstrate a remarkable evolution in design, sensitivity,
resolution, and complexity over the past thirty years.Comment: To appear in: Planets, Stars and Stellar Systems (PSSS), Volume 1:
Telescopes and Instrumentatio
- …