370 research outputs found

    Spectroscopy-based thrust sensor for high-speed gaseous flows

    Get PDF
    A system and method for non-intrusively obtaining the thrust value of combustion by-products of a jet engine is disclosed herein. The system includes laser elements for inducing absorption for use in determining the axial velocity and density of the jet flow stream and elements for calculating the thrust value therefrom

    Diode Laser Sensors for Arc-Jet Characterization

    Get PDF
    The development and application of tunable diode laser (TDL) absorption sensors to monitor the health and operating conditions in the large-scale 60 MW arc-heated- plasma wind-tunnel at NASA Ames Research Center is reported. The interactive heating facility (THF) produces re-entry flow conditions by expanding the gas heated in a constricted plasma arc-heater to flow at high velocity over a model located in a test cabin. This facility provides the conditions needed to test thermal protective systems for spacecraft re-entering the earth s atmosphere. TDL sensors are developed to monitor gas flows in both the high-temperature constricted flow and the supersonic expansion flow into test cabin. These sensors utilize wavelength-tuned diode lasers to measure absorption transitions of atomic oxygen near 777.2 nm, atomic nitrogen near 856.8 nm, and atomic copper near 793.3 nm. The oxygen and nitrogen sensors measure the population density in exited electronic states of these atoms. The measurements combined with the assumption of local thermal and chemical equilibrium yield gas temperature (typically near 7,000K). The nitrogen and oxygen population temperatures are redundant, and their close agreement provides an important test of the local thermal equilibrium assumption. These temperature sensors provide time-resolved monitors of the operating conditions of the arc-heater and can be used to verify and control the test conditions. An additional TDL sensor was developed to monitor the copper concentration in the arc-heater flow yielding values as high as 13 ppm. Measurements of copper in the flow can identify flow conditions with unacceptably rapid electrode erosion, and hence this sensor provides valuable information needed to schedule maintenance to avoid costly arc-heater failure. TDL sensors were also developed for measurements in the test cabin, where absorption measurements of the populations of argon and molecular nitrogen in excited metastable electronic states established that the number density of these excited species is much lower than estimated using frozen-chemistry approximations. This key finding suggests that in the post-expansion region there is not a significant energy sequestration in electronically excited species. Finally, TDL measurements of atomic potassium seeded into the test cabin flow were used to directly measure the static temperature of the test gas. The results of this study illustrate the high potential of time-resolved TDL measurements for routine and economical sensing of arc-heater health (gas temperature and electrode erosion) as well as the time-resolved test-cabin-flow conditions in front of the model

    AST Combustion Workshop: Diagnostics Working Group Report

    Get PDF
    A workshop was convened under NASA's Advanced Subsonics Technologies (AST) Program. Many of the principal combustion diagnosticians from industry, academia, and government laboratories were assembled in the Diagnostics/Testing Subsection of this workshop to discuss the requirements and obstacles to the successful implementation of advanced diagnostic techniques to the test environment of the proposed AST combustor. The participants, who represented the major relevant areas of advanced diagnostic methods currently applied to combustion and related fields, first established the anticipated AST combustor flowfield conditions. Critical flow parameters were then examined and prioritized as to their importance to combustor/fuel injector design and manufacture, environmental concerns, and computational interests. Diagnostic techniques were then evaluated in terms of current status, merits and obstacles for each flow parameter. All evaluations are presented in tabular form and recommendations are made on the best-suited diagnostic method to implement for each flow parameter in order of applicability and intrinsic value

    Tutorial: Remote entanglement protocols for stationary qubits with photonic interfaces

    Full text link
    Generating entanglement between distant quantum systems is at the core of quantum networking. In recent years, numerous theoretical protocols for remote entanglement generation have been proposed, of which many have been experimentally realized. Here, we provide a modular theoretical framework to elucidate the general mechanisms of photon-mediated entanglement generation between single spins in atomic or solid-state systems. Our framework categorizes existing protocols at various levels of abstraction and allows for combining the elements of different schemes in new ways. These abstraction layers make it possible to readily compare protocols for different quantum hardware. To enable the practical evaluation of protocols tailored to specific experimental parameters, we have devised numerical simulations based on the framework with our codes available online

    Entanglement between a diamond spin qubit and a photonic time-bin qubit at telecom wavelength

    Full text link
    We report on the realization and verification of quantum entanglement between an NV electron spin qubit and a telecom-band photonic qubit. First we generate entanglement between the spin qubit and a 637 nm photonic time-bin qubit, followed by photonic quantum frequency conversion that transfers the entanglement to a 1588 nm photon. We characterize the resulting state by correlation measurements in different bases and find a lower bound to the Bell state fidelity of F = 0.77 +/- 0.03. This result presents an important step towards extending quantum networks via optical fiber infrastructure

    Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

    Get PDF
    A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions

    In situ measurements of HCl during plasma etching of poly-silicon using a diode laser absorption sensor

    Full text link
    Tunable diode laser absorption spectroscopy is used to monitor hydrogen chloride (HCl) concentration in a commercial, high-density, low-pressure plasma reactor during plasma etching. A near-infrared diode laser is used to scan the P(4) transition in the first overtone of HCl near 1.79 µm to measure changes in HCl levels. A variety of HBr and Cl2 feedstock recipes are investigated at a process pressure of 10 mTorr as a function of rf power transformer coupled plasma, bias power and the total flow rate. Using 50 ms averaging and a signal modulation technique, we estimate a minimum detectivity of 4 × 10−6 in peak absorbance, which corresponds to an HCl number density of ∼2 × 1011 cm−3. The diode-laser based HCl sensor is sufficiently sensitive to detect small concentration variations and HCl concentration correlates with poly-Si etch rate for the conditions studied. These measurements demonstrate the feasibility of a real-time diode laser-based sensor for etch rate monitoring and the potential for process control.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/49064/2/e30918.pd
    • …
    corecore