1,864 research outputs found
What is required in terms of mass drug administration to interrupt the transmission of schistosome parasites in regions of endemic infection?
Supplementary information. (PDF 445 kb
Noninvasive genetic population survey of snow leopards (Panthera uncia) in Kangchenjunga conservation area, Shey Phoksundo National Park and surrounding buffer zones of Nepal
<p>Abstract</p> <p>Background</p> <p>The endangered snow leopard is found throughout major mountain ranges of Central Asia, including the remote Himalayas. However, because of their elusive behavior, sparse distribution, and poor access to their habitat, there is a lack of reliable information on their population status and demography, particularly in Nepal. Therefore, we utilized noninvasive genetic techniques to conduct a preliminary snow leopard survey in two protected areas of Nepal.</p> <p>Results</p> <p>A total of 71 putative snow leopard scats were collected and analyzed from two different areas; Shey Phoksundo National Park (SPNP) in the west and Kangchanjunga Conservation Area (KCA) in the east. Nineteen (27%) scats were genetically identified as snow leopards, and 10 (53%) of these were successfully genotyped at 6 microsatellite loci. Two samples showed identical genotype profiles indicating a total of 9 individual snow leopards. Four individual snow leopards were identified in SPNP (1 male and 3 females) and five (2 males and 3 females) in KCA.</p> <p>Conclusions</p> <p>We were able to confirm the occurrence of snow leopards in both study areas and determine the minimum number present. This information can be used to design more in-depth population surveys that will enable estimation of snow leopard population abundance at these sites.</p
Recommended from our members
The biomechanics of amnion rupture: an X-ray diffraction study
Pre-term birth is the leading cause of perinatal and neonatal mortality, 40% of which are attributed to the pre-term premature rupture of amnion. Rupture of amnion is thought to be associated with a corresponding decrease in the extracellular collagen content and/or increase in collagenase activity. However, there is very little information concerning the detailed organisation of fibrillar collagen in amnion and how this might influence rupture. Here we identify a loss of lattice like arrangement in collagen organisation from areas near to the rupture site, and present a 9% increase in fibril spacing and a 50% decrease in fibrillar organisation using quantitative measurements gained by transmission electron microscopy and the novel application of synchrotron X-ray diffraction. These data provide an accurate insight into the biomechanical process of amnion rupture and highlight X-ray diffraction as a new and powerful tool in our understanding of this process
A powerful bursting radio source towards the Galactic Centre
Transient astronomical sources are typically powered by compact objects and
usually signify highly explosive or dynamic events. While radio astronomy has
an impressive record of obtaining high time resolution observations, usually it
is achieved in quite narrow fields-of-view. Consequently, the dynamic radio sky
is poorly sampled, in contrast to the situation in the X- and gamma-ray bands
in which wide-field instruments routinely detect transient sources. Here we
report a new transient source, GCRT J1745-3009, detected in 2002 during a
moderately wide-field radio transient monitoring program of the Galactic center
(GC) region at 0.33 GHz. The characteristics of its bursts are unlike those
known for any other class of radio transient. If located in or near the GC, its
brightness temperature (~10^16 K) and the implied energy density within GCRT
J1745-3009 vastly exceeds that observed in most other classes of radio
astronomical sources, and is consistent with coherent emission processes rarely
observed. We conclude that GCRT J1745-3009 is the first member of a new class
of radio transient sources, the first of possibly many new classes to be
identified through current and upcoming radio surveys.Comment: 16 pages including 3 figures. Appears in Nature, 3 March 200
Sampling strategies for monitoring and evaluation of morbidity targets for soil-transmitted helminths
Background The current World Health Organization (WHO) target for the three major soil-transmitted helminth (STH) infections is to reduce prevalence of moderate-to-heavy infections to below 1% by 2020. In terms of monitoring and evaluation (M&E), the current WHO guidelines for control of STHs recommend evaluation of infection levels in school-age children (SAC) after five to six years of preventive chemotherapy (PC), using the standard Kato-Katz faecal smear. Here, we assess the predictive performance of various sampling designs for the evaluation of the morbidity target. Methodology/Principal findings Using two mathematical models for STH transmission and control, we simulate how the number of villages and SAC sampled affect the ability of survey results in sentinel villages to predict the achievement of the morbidity target in PC implementation units (e.g. districts). As PC is stopped when the prevalence of infection in SAC in sentinel villages is less than 1%, we estimate the positive predictive value (PPV) of this indicator for meeting the morbidity target in the whole district. The PPV varies by species and PC strategy, and it is generally higher in areas with lower pre-control prevalence. Sampling a fixed number of SAC spread out over 10 instead of 5 sentinel villages may increase the PPV by up to 20 percentage points. If every SAC in a village is tested, a higher number of villages may increase the PPV by up to 80 percentage points. Increasing the proportion of SAC tested per village does not result in a relevant increase of PPV. Conclusions/Significance Although the WHO guidelines provide a combined strategy to control the three STH species, the efficacy of PC strategies clearly differs by species. There is added value in considering more villages within implementation units for M&E of morbidity targets, the extent varying by STH species. A better understanding of pre- and post-control local STH prevalence levels is essential for an adequate M&E strategy including the definition of morbidity targets at the appropriate geographical scale
Analysis of factors influencing the ultrasonic fetal weight estimation
Objective: The aim of our study was the evaluation of sonographic fetal weight estimation taking into consideration 9 of the most important factors of influence on the precision of the estimation. Methods: We analyzed 820 singleton pregnancies from 22 to 42 weeks of gestational age. We evaluated 9 different factors that potentially influence the precision of sonographic weight estimation ( time interval between estimation and delivery, experts vs. less experienced investigator, fetal gender, gestational age, fetal weight, maternal BMI, amniotic fluid index, presentation of the fetus, location of the placenta). Finally, we compared the results of the fetal weight estimation of the fetuses with poor scanning conditions to those presenting good scanning conditions. Results: Of the 9 evaluated factors that may influence accuracy of fetal weight estimation, only a short interval between sonographic weight estimation and delivery (0-7 vs. 8-14 days) had a statistically significant impact. Conclusion: Of all known factors of influence, only a time interval of more than 7 days between estimation and delivery had a negative impact on the estimation
Obstetric professionalsâ perceptions of non-invasive prenatal testing for Down syndrome: clinical usefulness compared with existing tests and ethical implications
Background: While non-invasive prenatal testing (NIPT) for fetal aneuploidy is commercially available in many countries, little is known about how obstetric professionals in non-Western populations perceive the clinical usefulness of NIPT in comparison with existing first-trimester combined screening (FTS) for Down syndrome (DS) or invasive prenatal diagnosis (IPD), or perceptions of their ethical concerns arising from the use of NIPT. Methods: A cross-sectional survey among 327 obstetric professionals (237 midwives, 90 obstetricians) in Hong Kong. Results: Compared to FTS, NIPT was believed to: provide more psychological benefits and enable earlier consideration of termination of pregnancy. Compared to IPD, NIPT was believed to: provide less psychological stress for high-risk women and more psychological assurance for low-risk women, and offer an advantage to detect chromosomal abnormalities earlier. Significant differences in perceived clinical usefulness were found by profession and healthcare sector: (1) obstetricians reported more certain views towards the usefulness of NIPT than midwives and (2) professionals in the public sector perceived less usefulness of NIPT than the private sector. Beliefs about earlier detection of DS using NIPT were associated with ethical concerns about increasing abortion. Participants believing that NIPT provided psychological assurance among low-risk women were less likely to be concerned about ethical issues relating to informed decision-making and pre-test consultation for NIPT. Conclusions: Our findings suggest the need for political debate initially on how to ensure pregnant women accessing public services are informed about commercially available more advanced technology, but also on the potential implementation of NIPT within public services to improve access and equity to DS screening services
Identifying optimal threshold statistics for elimination of hookworm using a stochastic simulation model
Patient preferences for the allocation of deceased donor kidneys for transplantation: a mixed methods study
<p>Abstract</p> <p>Background</p> <p>Deceased donor kidneys are a scarce health resource, yet patient preferences for organ allocation are largely unknown. The aim of this study was to determine patient preferences for how kidneys should be allocated for transplantation.</p> <p>Methods</p> <p>Patients on dialysis and kidney transplant recipients were purposively selected from two centres in Australia to participate in nominal/focus groups in March 2011. Participants identified and ranked criteria they considered important for deceased donor kidney allocation. Transcripts were thematically analysed to identify reasons for their rankings.</p> <p>Results</p> <p>From six groups involving 37 participants, 23 criteria emerged. Most agreed that matching, wait-list time, medical urgency, likelihood of surviving surgery, age, comorbidities, duration of illness, quality of life, number of organs needed and impact on the recipient's life circumstances were important considerations. Underpinning their rankings were four main themes: enhancing life, medical priority, recipient valuation, and deservingness. These were predominantly expressed as achieving equity for all patients, or priority for specific sub-groups of potential recipients regarded as more "deserving".</p> <p>Conclusions</p> <p>Patients believed any wait-listed individual who would gain life expectancy and quality of life compared with dialysis should have access to transplantation. Equity of access to transplantation for all patients and justice for those who would look after their transplant were considered important. A utilitarian rationale based on maximizing health gains from the allocation of a scarce resource to avoid "wastage," were rarely expressed. Organ allocation organisations need to seek input from patients who can articulate preferences for allocation and advocate for equity and justice in organ allocation.</p
In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals
BACKGROUND: We need a sensor to measure the convective heat transfer coefficient during ablation of the heart or liver. METHODS: We built a minimally invasive instrument to measure the in vivo convective heat transfer coefficient, h in animals, using a Wheatstone-bridge circuit, similar to a hot-wire anemometer circuit. One arm is connected to a steerable catheter sensor whose tip is a 1.9 mm à 3.2 mm thin film resistive temperature detector (RTD) sensor. We used a circulation system to simulate different flow rates at 39°C for in vitro experiments using distilled water, tap water and saline. We heated the sensor approximately 5°C above the fluid temperature. We measured the power consumed by the sensor and the resistance of the sensor during the experiments and analyzed these data to determine the value of the convective heat transfer coefficient at various flow rates. RESULTS: From 0 to 5 L/min, experimental values of h in W/(m(2)¡K) were for distilled water 5100 to 13000, for tap water 5500 to 12300, and for saline 5400 to 13600. Theoretical values were 1900 to 10700. CONCLUSION: We believe this system is the smallest, most accurate method of minimally invasive measurement of in vivo h in animals and provides the least disturbance of flow
- âŚ