22 research outputs found
QMix® irrigant reduces lipopolysacharide (LPS) levels in an in vitro model
AbstractThe presence of endotoxin inside the root canal has been associated with periapical inflammation, bone resorption and symptomatic conditions.Objectives To determine, in vitro, the effect of QMix® and other three root canal irrigants in reducing the endotoxin content in root canals.Material and Methods Root canals of single-rooted teeth were prepared. Samples were detoxified with Co-60 irradiation and inoculated with E. coli LPS (24 h, at 37°C). After that period, samples were divided into 4 groups, according to the irrigation solution tested: QMix®, 17% EDTA, 2% chlorhexidine solution (CHX), and 3% sodium hypochlorite (NaOCl). LPS quantification was determined by Limulus Amebocyte Lysate (LAL) assay. The initial counting of endotoxins for all samples, and the determination of LPS levels in non-contaminated teeth and in contaminated teeth exposed only to non-pyrogenic water, were used as controls.Results QMix® reduced LPS levels, with a median value of 1.11 endotoxins units (EU)/mL (p<0.001). NaOCl (25.50 EU/mL), chlorhexidine (44.10 EU/mL) and positive control group (26.80 EU/mL) samples had similar results. Higher levels were found with EDTA (176.00 EU/mL) when compared to positive control (p<0.001). There was no significant difference among EDTA, NaOCl and CHX groups. Negative control group (0.005 EU/mL) had statistically significant lower levels of endotoxins when compared to all test groups (p<0.001).Conclusion QMix® decreased LPS levels when compared to the other groups (p<0.001). 3% NaOCl, 2% CHX and 17% EDTA were not able to significantly reduce the root canal endotoxins load
Spectrophotometric analysis of crown discoloration induced by MTA- and ZnOE-based sealers
Crown discoloration can be induced by root canal sealer remnants following root canal treatment. OBJECTIVE: The aim of this study was to evaluate chromatic alterations in human tooth crowns induced by a Mineral Trioxide Aggregate-based sealer (MTA Fillapex(®) and a commonly used ZnOE-based sealer (Roth-811). The tested null hypothesis was that the application of the materials did not induce clinically perceptible crown discoloration (Ho: CIE color difference ΔE<3.7). MATERIAL AND METHODS: Forty five fully developed, intact, mandibular third molars were sectioned 1 mm below the cemento-enamel junction. The pulp chambers were chemomechanically debrided via the cervical access. The specimens were randomly assigned into three groups Group 1: MTA Fillapex, Group 2: Roth 811, Group 3: Negative control (unfilled) and immersed in individually marked vials containing distilled water up to the cervix (37±1º C). The spectral reflectance lines were recorded by utilizing a UV-VIS spectrophotometer equipped with integration sphere in the visual spectrum at baseline, 1 week, 1 and 3 months after material placement. Data were transformed into values of the CIE L*a*b* color system and the corresponding ΔE values were calculated. Statistical analysis was performed using two-way mixed ANOVA models, at p=0.05 level of significance. RESULTS: A statistically significant increase in a* and b* chromatic parameters of the MTA Fillapex Group was measured. However, ΔE values did not exceed the human eye perceptibility threshold (set at ΔE<3.7) during the experimental period (ΔEt3=2.88). In Roth-811 Group, a statistically significant decrease in L* and a statistically significant increase in a* and b* chromatic parameters was measured, during all observation periods. Resultant ΔE values exceeded the human eye perceptibility threshold after 1 week (ΔEt1=5.65). CONCLUSIONS: Application of MTA Fillapex in tooth crowns resulted in minimal color alterations, while Roth 811 induced severe discoloration, in vitro. It could be suggested that, in terms of aesthetics, the use of MTA Fillapex appears to be favorable
Human tooth germ stem cell response to calcium-silicate based endodontic cements
OBJECTIVE: The aim of this study was to compare the cytotoxic effects of endodontic cements on human tooth germ stem cells (hTGSCs). MTA Fillapex, a mineral trioxide aggregate (MTA)-based, salicylate resin containing root canal sealer, was compared with iRoot SP, a bioceramic sealer, and AH Plus Jet, an epoxy resin-based root canal sealer. MATERIAL AND METHODS: To evaluate cytotoxicity, all materials were packed into Teflon rings (4 mmµ3 mm) and co-cultured with hTGSCs with the aid of 24-well Transwell permeable supports, which had a pore size of 0.4 µm. Coverslips were coated with MTA Fillapex, iRoot SP and AH Plus Jet and each coverslip was placed onto the bottom of one well of a six-well plate for scanning electron microscopy (SEM) analysis. Before the cytotoxicity and SEM analysis, all samples were stored at 37ºC and at 95% humidity and 5% CO(2) for 24 hours to set. The cellular viability was analyzed using MTS test (3-(4,5-dimethyl-thiazol-2-yl)-5-(3-carboxy-methoxy-phenyl)-2-(4-sulfo-phenyl)-2H-tetrazolium). The cytotoxic effects and SEM visualization of the tested materials were analyzed at 24-hour, 72-hour, one-week and two-week periods. RESULTS: On the 1(st) day, only MTA Fillapex caused cytotoxicity compared to negative control (NC) group (p<0.008). No significant difference was observed between the other tested materials at this period (p>0.05). After 14 days of incubation with the test materials, MTA Fillapex exhibited significantly higher cytotoxicity compared with iRoot SP, AH Plus Jet and the NC group (P<0.008). In the SEM analysis, the highest levels of cell attachment were observed for iRoot SP and the control group. After 24 hours, MTA Fillapex reduced the number of cells attached to the surface. CONCLUSIONS: Within the limitations of this study, sealers exerted different cytotoxic effects on hTGSCs. Although all materials have exerted cellular toxicity, iRoot SP and AH Plus Jet may promote better attachment to hTGSCs
Influence of endodontic sealer composition and time of fiber post cementation on sealer adhesiveness to bovine root dentin
This study aimed to assess the influence of the type of endodontic sealer (salicylate resinbased sealer vs. two endodontic sealers) and the time of fiber post cementation after root filling on the post adhesion to bovine root dentin. Sixty bovine roots were assigned to six groups (n=10), considering an experimental design with two factors (factorial 3x2): endodontic sealer factor in three levels [epoxy resin-based sealer (AH Plus), eugenol-based sealer (Endofill), and salicylate resin-based sealer plus mineral trioxide aggregate - MTA (MTA Fillapex)] and time for post cementation factor in two levels (immediate post cementation or 15 days after root canal filling). After post cementation, 2-mm-thick slices were produced and submitted to push-out test. The failure modes were analyzed under a 40× stereomicroscope and scored as: adhesive at cement/dentin interface; adhesive at cement/post interface; cement cohesive; post cohesive; dentin cohesive; or mixed. Data were analyzed using two-way ANOVA and Tukey’s post-hoc tests (α=0.05). When the fiber posts were cemented immediately after the root canal filling, the bond strengths were similar, independent of the endodontic sealer type. However, after 15 days, the epoxy resin-based sealer presented higher bond strength than the other sealers (p<0.05). Comparison between each sealer in different experimental times did not reveal any differences. The main failure type was adhesive at dentin/cement interface (89.4%). The time elapsed between the root canal filling and post cementation has no influence on post/root dentin adhesion. On the contrary, the type of endodontic sealer can influence the adhesion between fiber posts and root dentin.Este estudo objetivou avaliar a influência do tipo de cimento endodôntico (um cimento à base de resina de salicilato e dois cimentos endodônticos) e do tempo decorrido entre a obturação do conduto e a cimentação do pino de fibra na adesão de pinos de fibra à dentina radicular bovina. Sessenta dentes bovinos foram divididos em seis grupos (n=10), considerando um desenho experimental de dois fatores (3x2): cimento endodôntico em três níveis [à base de resina epóxica (AH Plus), eugenol (Endofill) e resina de salicilato e MTA (MTA Fillapex)] e o tempo para cimentação em dois níveis (cimentação imediata e 15 dias pós a obturação). Após cimentação do pino de fibra, fatias com 2 mm de espessura foram obtidas e submetidas ao teste de push-out. Os padrões de falha foram analisados em estereomicroscópio (40×) e classificados em: adesiva na interface cimento/dentina, adesiva cimento/pino, coesiva do cimento, coesiva do pino, coesiva da dentina e mista. Os dados foram analisados através dos testes de ANOVA a dois fatores e post hoc de Tukey (a=0,05). Quando os pinos de fibra foram cimentados imediatamente após a obturação dos condutos, a resistência adesiva foi similar, independentemente do tipo de cimento endodôntico. Entretanto, após 15 dias, os dentes obturados com cimento resinoso à base de resina epóxica apresentaram os maiores valores de resistência adesiva (p<0,05). Os valores de resistência adesiva do mesmo cimento nos diferentes tempos experimentais não foram alterados. O principal tipo de falha foi adesiva na interface cimento/ dentina (89,4%). O tempo decorrido entre a obturação dos condutos e a cimentação do pino não influenciou a adesão do pino de fibra à dentina radicular. Por outro lado, o tipo de cimento endodôntico influencia a adesão entre dentina radicular e pinos de fibra
Effects of calcium hydroxide addition on the physical and chemical properties of a calcium silicate-based sealer
Recently, various calcium silicate-based sealers have been introduced for use in root canal filling. The MTA Fillapex is one of these sealers, but some of its physicochemical properties are not in accordance with the ISO requirements. Objective: The aim of this study was to evaluate the flowability, pH level and calcium release of pure MTA Fillapex (MTAF) or containing 5% (MTAF5) or 10% (MTAF10) calcium hydroxide (CH), in weight, in comparison with AH Plus sealer. Material and Methods: The flowability test was performed according to the ISO 6876: 2001 requirements. For the pH level and calcium ion release analyses, the sealers were placed individually (n=10) in plastic tubes and immersed in deionized water. After 24 hours, 7 and 14 days, the water in which each specimen had been immersed was evaluated to determine the pH level changes and calcium released. Flowability, pH level and calcium release data were analyzed statistically by the ANOVA test (alpha=5%). Results: In relation to flowability: MTAF>AH Plus>MTAF5>MTAF10. In relation to the pH level, for 24 h: MTAF5=MTAF10=MTAF>AH Plus; for 7 and 14 days: MTAF5=MTAF10>MTAF>AH Plus. For the calcium release, for all periods: MTAF>MTAF5=MTAF10>AH Plus. Conclusions: The addition of 5% CH to the MTA Fillapex (in weight) is an alternative to reduce the high flowability presented by the sealer, without interfering in its alkalization potential
Effect of pre-flaring and file size on the accuracy of two electronic apex locators
OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size