1,600 research outputs found
Commissioning of the MEG II tracker system
The MEG experiment at the Paul Scherrer Institut (PSI) represents the state
of the art in the search for the charged Lepton Flavour Violating (cLFV) decay. With the phase 1, MEG set the new world best
upper limit on the \mbox{BR}(\mu^+ \rightarrow e^+ \gamma) < 4.2 \times
10^{-13} (90% C.L.). With the phase 2, MEG II, the experiment aims at reaching
a sensitivity enhancement of about one order of magnitude compared to the
previous MEG result. The new Cylindrical Drift CHamber (CDCH) is a key detector
for MEG II. CDCH is a low-mass single volume detector with high granularity: 9
layers of 192 drift cells, few mm wide, defined by wires in a
stereo configuration for longitudinal hit localization. The filling gas mixture
is Helium:Isobutane (90:10). The total radiation length is
\mbox{X}_0, thus minimizing the Multiple Coulomb Scattering (MCS)
contribution and allowing for a single-hit resolution m and an
angular and momentum resolutions of 6 mrad and 90 keV/c respectively. This
article presents the CDCH commissioning activities at PSI after the wiring
phase at INFN Lecce and the assembly phase at INFN Pisa. The endcaps
preparation, HV tests and conditioning of the chamber are described, aiming at
reaching the final stable working point. The integration into the MEG II
experimental apparatus is described, in view of the first data taking with
cosmic rays and beam during the 2018 and 2019 engineering runs. The
first gas gain results are also shown. A full engineering run with all the
upgraded detectors and the complete DAQ electronics is expected to start in
2020, followed by three years of physics data taking.Comment: 10 pages, 12 figures, 1 table, proceeding at INSTR'20 conference,
accepted for publication in JINS
Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium
The mirror relative motion of a suspended Fabry-Perot cavity is studied in
the frequency range 3-10 Hz. The experimental measurements presented in this
paper, have been performed at the Low Frequency Facility, a high finesse
optical cavity 1 cm long suspended to a mechanical seismic isolation system
identical to that one used in the VIRGO experiment. The measured relative
displacement power spectrum is compatible with a system at thermal equilibrium
within its environmental. In the frequency region above 3 Hz, where seismic
noise contamination is negligible, the measurement distribution is stationary
and Gaussian, as expected for a system at thermal equilibrium. Through a simple
mechanical model it is shown that: applying the fluctuation dissipation theorem
the measured power spectrum is reproduced below 90 Hz and noise induced by
external sources are below the measurement.Comment: 11 pages, 9 figures, 2 tables, to be submitte
Memory beyond memory in heart beating: an efficient way to detect pathological conditions
We study the long-range correlations of heartbeat fluctuations with the
method of diffusion entropy. We show that this method of analysis yields a
scaling parameter that apparently conflicts with the direct evaluation
of the distribution of times of sojourn in states with a given heartbeat
frequency. The strength of the memory responsible for this discrepancy is given
by a parameter , which is derived from real data. The
distribution of patients in the (, )-plane yields a neat
separation of the healthy from the congestive heart failure subjects.Comment: submitted to Physical Review Letters, 5 figure
Cabergoline, prolactin and heart
Summary Introduction and aim: Dopamine agonists have been reported to increase the risk of cardiac valve regurgitation in patients with Parkinson's disease. However, it is unknown whether these drugs might be harmful for patients with hyperprolactinaemia (HyperPRL). The aim of the study was to evaluate whether HyperPRL patients treated with dopamine agonists had a higher prevalence of cardiac valves regurgitation than that of general population. Methods and patients: One hundred consecutive patients (79 women, 21 men, mean age 41 ± 13 years) with HyperPRL during treatment with cabergoline were enrolled in an observational case–control study and compared with 100 matched normal subjects (controls). Valve regurgitation was assessed by echocardiography according to the American Society of Echocardiography recommendations. Results: Seven HyperPRL patients (7%) and six controls (6%) had moderate (grade 3) regurgitation in any valve (p = 0.980). All were asymptomatic and had no signs of cardiac disease. Mean duration of cabergoline treatment was 67 ± 39 months (range: 3–199 months). Mean cumulative dose of cabergoline was 279 ± 301 mg (range: 15–1327 mg). Moderate valve regurgitation was not associated with the duration of treatment (p = 0.359), with cumulative dose of cabergoline (p = 0.173), with age (p = 0.281), with previous treatment with bromocriptine (p = 0.673) or previous adenomectomy (p = 0.497) in patients with HyperPRL. Discussion: In conclusion, treatment with cabergoline was not associated with increased prevalence of cardiac valves regurgitation in patients with HyperPRL. Mean cumulative dose of cabergoline was lower in patients with HyperPRL than that reported to be deleterious for patients with Parkinson's disease: hence, longer follow-up is necessary, particularly in patients receiving weekly doses > 3 mg
An update on treatment options for interstitial cystitis
Interstitial cystitis or bladder pain syndrome (IC/BPS) is a chronic pelvic pain syndrome related to the urinary bladder. The ideal treatment should match as much as possible with the pathophysiologic causes of the IC/BPS, but the scarcely available evidence limits this approach, with the majority of available treatments that are primarily targeted to the control of symptoms. The treatment strategies have traditionally focused on the bladder, which is considered the primary end-organ and source of pain. Nevertheless, the growing body of evidence suggests a multifaceted nature of the disease with systemic components. In general, guidelines recommend the personalized and progressive approach, that starts from the more conservative options and then advances toward more invasive and combined treatments. The behavioral changes represent the first and most conservative steps. They can be combined with oral medications or progressively with intravesical instillation of drugs, up to more invasive techniques in a combined way. Despite the multiple available options, the optimal treatment is not easy to be found. Only further investigation on the etiopathogenetic mechanisms, taking into account the differences among subgroups, and the interaction between central and peripherical factors may allow providing a real improvement in the treatment and management of these patients
Design, status and perspective of the Mu2e crystal calorimeter
The Mu2e experiment at Fermilab will search for the charged lepton flavor
violating process of neutrino-less coherent conversion in the field
of an aluminum nucleus. Mu2e will reach a single event sensitivity of about
that corresponds to four orders of magnitude improvements
with respect to the current best limit. The detector system consists of a straw
tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon
Photomultipliers. The calorimeter was designed to be operable in a harsh
environment where about 10 krad/year will be delivered in the hottest region
and work in presence of 1 T magnetic field. The calorimeter role is to perform
/e separation to suppress cosmic muons mimiking the signal, while
providing a high level trigger and a seeding the track search in the tracker.
In this paper we present the calorimeter design and the latest RD results.Comment: 4 pages, conference proceeding for a presentation held at TIPP'2017.
To be published on Springer Proceedings in Physic
Quality Assurance on a custom SiPMs array for the Mu2e experiment
The Mu2e experiment at Fermilab will search for the coherent
conversion on aluminum atoms. The detector system consists of a straw tube
tracker and a crystal calorimeter. A pre-production of 150 Silicon
Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed
quality assur- ance has been carried out on each SiPM for the determination of
its own operation voltage, gain, dark current and PDE. The measurement of the
mean-time-to-failure for a small random sample of the pro-production group has
been also completed as well as the determination of the dark current increase
as a function of the ioninizing and non-ioninizing dose.Comment: 4 pages, 10 figures, conference proceeding for NSS-MIC 201
- …