17 research outputs found

    Syncope recurrence and mortality : a systematic review

    No full text
    AIMS: Data on adverse events and death rates following syncope are heterogeneous among studies, and knowledge of syncope prognosis could help to better define the correct management of patients. METHODS AND RESULTS: We performed a systematic review of literature by searching for prospective observational studies enrolling consecutive patients presenting to the Emergency Department because of syncope. The outcomes considered were syncope recurrence and short- and long-term mortality. Morbidity and a composite of morbidity and mortality were also assessed. Pooled event rates and 95% confidence intervals (CI) were calculated for each outcome using the random effects model. Twenty-five studies (11 158 patients) were included. The incidence of syncope relapse linearly increased from 0.3% at 30 days to 22% at 2 years follow-up. One-year mortality rate varied between 5.7 and 15.5%; the pooled estimate was 8.4% (95% CI: 6.7-10.2%). The incidence of adverse events (morbidity) varied between 6.1 and 25.2% at 10 days and 2 years, respectively. The short-term (10 days) pooled incidence of the composite of morbidity and mortality was 9.1% (95% CI: 6.6-12.5%). We found a high statistical heterogeneity between studies. CONCLUSION: This meta-analysis of prospective observational studies shows that the chance of being asymptomatic linearly progressively decreased over time after the first syncope. Short-term (10-30 days) mortality after syncope was <2% and that the overall 10-day rate of the composite endpoint of death and major events was 9%. The knowledge of syncope prognosis could help clinicians to understand syncope patients' prognosis and researchers to design future studies

    Outcomes in syncope research : a systematic review and critical appraisal

    No full text
    Syncope is the common clinical manifestation of different diseases, and this makes it difficult to define what outcomes should be considered in prognostic studies. The aim of this study is to critically analyze the outcomes considered in syncope studies through systematic review and expert consensus. We performed a systematic review of the literature to identify prospective studies enrolling consecutive patients presenting to the Emergency Department with syncope, with data on the characteristics and incidence of short-term outcomes. Then, the strengths and weaknesses of each outcome were discussed by international syncope experts to provide practical advice to improve future selection and assessment. 31 studies met our inclusion criteria. There is a high heterogeneity in both outcome choice and incidence between the included studies. The most commonly considered 7-day outcomes are mortality, dysrhythmias, myocardial infarction, stroke, and rehospitalisation. The most commonly considered 30-day outcomes are mortality, haemorrhage requiring blood transfusion, dysrhythmias, myocardial infarction, pacemaker or implantable defibrillator implantation, stroke, pulmonary embolism, and syncope relapse. We present a critical analysis of the pros and cons of the commonly considered outcomes, and provide possible solutions to improve their choice in ED syncope studies. We also support global initiatives to promote the standardization of patient management and data collection

    A systematic review of noninvasive electrocardiogram monitoring devices for the evaluation of suspected cardiovascular syncope

    No full text
    The aims of this study were (1) to identify research publications studying noninvasive electrocardiogram (ECG) monitoring devices, (2) to define and categorize current technology in noninvasive ECG recording, and (3) to discuss desirable noninvasive recording features for personalized syncope evaluation to guide technological advancement and future studies. We performed a systematic review of the literature that assessed noninvasive ECG-monitoring devices, regardless of the reason for monitoring. We performed an Internet search and corresponded with syncope experts and companies to help identify further eligible products. We extracted information about included studies and device features. We found 173 relevant papers. The main reasons for ECG monitoring were atrial fibrillation (n = 45), coronary artery disease (n = 10), syncope (n = 8), palpitations (n = 8), other cardiac diseases (n = 67), and technological aspects of monitoring (n = 35). We identified 198 devices: 5 hospital telemetry devices, 12 patches, 46 event recorders, 70 Holter monitors, 23 external loop recorders, 20 mobile cardiac outpatient telemetries, and 22 multifunctional devices. The features of each device were very heterogeneous. There are a large number of ECG-monitoring devices with different features available in the market. Our findings may help clinicians select the appropriate device for their patients. Since there are only a few published articles analyzing their usefulness in syncope patients, further research might improve their use in this clinical setting
    corecore