27 research outputs found

    Study of Charm Fragmentation into D^{*\pm} Mesons in Deep-Inelastic Scattering at HERA

    Get PDF
    The process of charm quark fragmentation is studied using D±D^{*\pm} meson production in deep-inelastic scattering as measured by the H1 detector at HERA. Two different regions of phase space are investigated defined by the presence or absence of a jet containing the D±D^{*\pm} meson in the event. The parameters of fragmentation functions are extracted for QCD models based on leading order matrix elements and DGLAP or CCFM evolution of partons together with string fragmentation and particle decays. Additionally, they are determined for a next-to-leading order QCD calculation in the fixed flavour number scheme using the independent fragmentation of charm quarks to D±D^{*\pm} mesons.Comment: 33 pages, submitted to EPJ

    Monte Carlo simulation of transition radiation and delta electrons

    No full text
    SIGLECopy held by FIZ Karlsruhe; available from UB/TIB Hannover / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman

    H1 backward upgrade with a SPACAL calorimeter: the hadronic section

    No full text
    The design, technological aspects, tests and first results on performance of the hadronic section of the H1 Backward Lead/Scintillating-Fibre Hadronic Calorimeter are described and discussed. (orig.)7 refs.Available from TIB Hannover: RA 2999(96-013) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDEGerman

    The H1 lead/scintillating-fibre calorimeter

    No full text
    The backward region of the H1 detector has been upgraded in order to provide improved measurement of the scattered electron in deep inelastic scattering events. The centerpiece of the upgrade is a high-resolution lead/scintillating-fibre calorimeter. The main design goals of the calorimeter are: good coverage of the region close to the beam pipe, high angular resolution and energy resolution of better than 2% for 30 GeV electrons. The calorimeter should be capable of providing coarse hadronic energy measurement and precise time information to suppress out-of-time background events at the first trigger level. It must be compact due to space restrictions. These requirements were fulfilled by constructing two separate calorimeter sections. The inner electromagnetic section is made of 0.5 mm scintillating plastic fibres embedded in a lead matrix. Its lead-to-fibre ratio is 2.3:1 by volume. The outer hadronic section consists of 1.0 mm diameter fibres with a lead-to-fibre ratio of 3.4:1. The mechanical construction of the new calorimeter and its assembly in the H1 detector are described. (orig.)Available from TIB Hannover: RA 2999(96-171) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDEGerman

    Electromagnetic calorimetry with lead fluoride crystals

    No full text
    The properties of four PbF_2 crystals of size 21.21.175 mm"3 were studied with electron and pion beams in the energy range from 1 to 6 GeV. An energy resolution for electrons of 6.3%/#sq root#(E/GeV) was achieved with a 2x2 matrix of four PbF_2 crystals, which corresponds to 5.6%/#sq root#(E/GeV) when corrected for lateral leakage by Monte Carlo simulations. The deviation from linearity was smaller than 0.5%. The time resolution was found to be better than 0.6 ns. We studied also optical properties, radiation hardness, position resolution and spatial homogeneity. An efficient separation of electromagnetic and hadronic showers was achieved. (orig.)Available from TIB Hannover: RA 2999(93-143) / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDEGerman
    corecore